General Safety Information

Speedaire exhaust reclassifiers are utilized in
a variety of air system applications. Because
the exhaust reclassifier and other
components (compressor, spray gun, filters,
regulators, lubricators, hoses, etc.) make up a
high pressure pumping system, the following
safety precautions should be observed at all
times.
1. Read the instruction manuals for each

component carefully before attempting to
assemble, disassemble, or operate your
particular system.

2. Do not exceed the pressure rating of any

component in the system.

3. Protect material lines and air lines from

damage or puncture.

4. Never point a spray gun at oneself or any

other person. Accidental discharge may
result in serious injury.

5. Check hoses for weak or worn condition

before each use, making certain that all
connections are secure.

6. Release all pressures within the system

before attempting to service any
component.

Materials

Body: Aluminum
Sump: Polypropylene
Element: Steel, synthetic foam and fiber
Elastomer: Nitrile

Installation

1. Shut OFF air pressure. Install exhaust

reclassifier vertically (bowl down). Mount
in a location that will allow easy access for
draining sump.

2. It may be necessary to add a flow control

valve to the outlet of the air motor or
valve exhaust port if motor or cylinder
extension or retraction speeds need to be
regulated.

3. Multiple small valve exhausts may be

plumbed into one exhaust reclassifier
providing that the maximum pressure
rating of the reclassifier unit will not be
exceeded. Use a pressure manifold (rated
for the maximum pressure of your air
supply) for this purpose.

4. The temperature of the air entering the

reclassifier filter element must not exceed
the maximum temperature rating of the
unit. The reclassifier must not be used on
heat regenerated air dryers!

Operation

1.Open manual drain to expel accumulated

liquids.

2. If coalescing filters are used to filter the

inlet air prior to the regulator or
lubricator, the service life of the exhaust
reclassifier element will be greatly
increased. If sub-micronic filtration is not
used, reclassifier element life will depend
on the exhaust flow rate and exhaust air
contamination. The exhaust reclassifier
element should be replaced periodically.

Disassembly

1. Exhaust reclassifier can be disassembled

without removal from air line.

2. Shut OFF inlet pressure. Reduce pressure

in inlet line to zero.

3. Unsnap and remove sump.

4. Unscrew exhaust reclassifier element.

Assembly

1. Use a wrench to tighten the element.

Tightening by hand could damage the
filter element, or cause it to loosen in the
end caps. Tighten only to obtain a snug
fit. Do not over tighten. Over tightening
can crack the element end cap. Never
operate the exhaust reclassifier with a
cracked end cap or loose element. Injury
and/or property damage may result.

2. Snap sump into body.

Repair Parts Information

Element:

4ZL96: 3236-01
4ZL97, 4ZL98: 3237-01

Sump with drain:

4ZL96: 70048-50
4ZL97, 4ZL98: 70048-51

For Repair Parts,
call 1-800-323-0620
24 hours a day - 365 days a year

Please provide following information:
- Model number
- Serial number (if any)
- Part description and number as shown

in parts list

Model

A Diameter

B

4ZL96

3.54 (90)

7.09 (180)

4ZL97

4.33 (110)

10.51 (267)

4ZL98

4.33 (110)

10.51 (267)

Speedaire

®

Exhaust Reclassifier

Refer to Form 5S6040 for General Safety Information and Warranty

Operating Instructions & Parts Manual

4ZL96, 4ZL97, 4ZL98

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.

Form 5S6084

®

E

N
G

L

I

S

H

E
S
P

A
Ñ
O

L

F

R

A
N

Ç

A

I

S

Printed in U.S.A.
06530
0708/254/VCPVP

Description

Speedaire exhaust reclassifiers are used to capture harmful contaminants from your air
system and to lower exhaust noise to help comply with OSHA requirements. The exhaust
reclassifier’s construction allows for high exhaust flows with very low pressure drop.

4ZL96

150 psi

160°F

35 cfm

1/2"

1.1

4ZL97

150

160

100

1

2.2

4ZL98

150

160

100

1-

1

/

4

2.2

Maximum
Inlet

Maximum

Maximum

Weight

Model

Pressure

Temperature

CFM

Port

(lbs)

Specifications

A

B

Figure 1 - Dimensions in inches (mm)

5S5329:5S4391

8/30/08  7:08 PM  Page 1

Summary of Contents for 4ZL96

Page 1: ...reclassifier element life will depend on the exhaust flow rate and exhaust air contamination The exhaust reclassifier element should be replaced periodically Disassembly 1 Exhaust reclassifier can be disassembled without removal from air line 2 Shut OFF inlet pressure Reduce pressure in inlet line to zero 3 Unsnap and remove sump 4 Unscrew exhaust reclassifier element Assembly 1 Use a wrench to ti...

Page 2: ...asificador depende del caudal de escape y de la contaminación del aire del escape El elemento del reclasifi cador de escape debe reemplazarse periódicamente Desmontaje 1 El reclasificador de escape se puede desmontar sin necesidad de retirarlo de la línea de aire 2 INTERRUMPA la presión de entrada Reduzca la presión en la línea de entrada a cero 3 Desenganche y retire el sumidero 4 Desenrosque el ...

Page 3: ...le du reclasseur dépendra du débit d évacuation et de la contamination de l air d évacuation L élément du reclasseur d échappement doit être remplacé régulièrement Démontage 1 Le reclasseur d échappement peut être démonté sans être retiré de la conduite d air 2 COUPER l alimentation en air comprimé Réduire à zéro la pression de la conduite d alimentation 3 Déboîter et retirer le bassin collecteur ...

Page 4: ...n Electric Mfg Co Fabricado para Niles Illinois 60714 U S A Fabriqué pour Notes Speedaire Operating Instructions and Parts Manual Manual de instrucciones de operación y lista de partes Speedaire Manuel d utilisation et de pièces détachées Speedaire 5S5329 5S4391 8 30 08 7 08 PM Page 4 ...

Reviews: