background image

Food Safety Thermometer

800115

Instruction Manual

Summary of Contents for 800115

Page 1: ...Food Safety Thermometer 800115 Instruction Manual ...

Page 2: ...2 TABLE OF CONTENTS INTRODUCTION 3 FEATURES 4 MATERIAL SUPPLIED 4 FRONT PANEL DESCRIPTION 5 LCD DISPLAY 6 SET UP 7 MEASUREMENT PROCEDURES 12 CARE AND MAINTENANCE 14 SPECIFICATIONS 15 WARRANTY 16 ...

Page 3: ...rature regulations is needed such as with prepared meats fish or poultry simply fold out the penetration probe and see the internal temperature displayed on the large backlit LCD display The thermometer offers a flashlight feature a probe that can extend to several operating angles and quickly switches between IR and penetration The programmable high and low alarms allow staff to successfully spot...

Page 4: ...4 FEATURES IP65 waterproof HACCP compliant High Low alarm settings Flashlight Multi position penetration probe Backlit LCD MATERIALS SUPPLIED Food Safety Thermometer 2 AAA batteries Instruction manual ...

Page 5: ...5 FRONT PANEL DESCRIPTION 1 Infrared sensor and flashlight 2 LCD screen 3 SCAN button 4 LIGHT UNIT button 5 SET button 6 Penetration probe 6 1 2 3 4 5 ...

Page 6: ... 1 IR Temperature Active Indicator 2 Hold Function Indicator 3 Temperature Unit of Measure 4 Temperature Reading 5 Low Battery Indicator 6 Probe Temperature Active Indicator 7 Low or High Alarm Active 6 7 5 4 3 2 1 ...

Page 7: ...st use 1 Unscrew the single screw on the back of the thermometer 2 Remove the battery cover 3 Insert two new AAA batteries ensuring correct polarity 4 Reinstall the batter cover Replace the batteries when the low battery icon appears on the LCD Note Before replacing the batteries turn the thermometer off ...

Page 8: ...ly measurements Method Two 1 Using the thumb notch fold the penetrating probe out This automatically turns the thermometer on 2 Fold the penetration probe back in to turn it off Changing the Unit of Measure 1 Turn the thermometer on 2 Press SET until C or F flashes on the LCD above the last recorded temperature 3 Press SCAN to toggle between C and F 4 Press SET to confirm The thermometer will powe...

Page 9: ...s per second 1 Turn the thermometer on 2 Press SET repeatedly until the icon appears on the LCD with a number 3 Adjust the LOW alarm value using the SCAN and LIGHT buttons 4 Press SET to confirm 5 The thermometer will power off and save the LOW alarm setting 6 Press SET repeatedly until the icon appears on the LCD with the word on or off 7 Press SCAN to choose whether the audible alarm is on or of...

Page 10: ... SCAN and LIGHT buttons 4 Press SET to confirm 5 The thermometer will power off and save the HIGH alarm setting 6 Press SET repeatedly until the icon appears on the LCD along with the word on or off 7 Press SCAN to choose whether the audible alarm is active On or silent Off 8 Press SET to confirm The thermometer will power off and retain the setting ...

Page 11: ...ower is on Flashlight Press the central LIGHT button to turn the Flashlight on IMPORTANT The flashlight area does not represent the infrared measuring area The white circle that appears in IR mode is for aiding visibility and does not represent the distance to spot ratio ...

Page 12: ...end of the metal probe into food to at least 4mm 3 The temperature is displayed on the screen 4 PRO TEMP appears on the screen whenever this probe is in use Infrared Thermometer Note Infrared mode works whether the penetration probe is folded closed or extended open Be sure that PRO TEMP does not appear on the screen when taking infrared readings 1 Aim the infrared sensor at the object to be measu...

Page 13: ...ter the scan button is released The high and low alarms will only sound while the SCAN button is engaged The alarm shuts of when you release the button IMPORTANT SAFETY NOTE The penetration probe is sharp Be sure to keep your hand clear of the probe when using IR mode to avoid injury NOTE The white lighted circle does not represent the measuring area The measuring area has a distance to spot ratio...

Page 14: ...sinfecting agent when necessary for food safety Store the thermometer with the temperature probe in the closed position Repairs or services not covered in this manual should be performed by qualified personnel only Please contact Sper Scientific to speak with a technician ...

Page 15: ... freezing 1 C 1 8 F for all other temperatures Infrared Thermometer 40 200 C 40 392 F 0 1 3 C 5 4 F from 40 20 C 1 C 1 8 F for all other temperatures Infrared Distance to Spot Ratio 4 1 Waterproof Rating IP65 Measurement Response Time 500mS Emissivity Fixed at 0 95 Battery Type 2 x AAA batteries 1 5V ...

Page 16: ... does not cover batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the thermometer to expose its electronics will break the waterproof seal and void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 E Evans Rd Suite 103 Scottsdale AZ 85260 480 948 4448 The defective unit must be accompanied by...

Reviews: