background image

SportsArt – 8100 Elliptical Trainer – Incline Calibration Guide 

 
Table of Contents   

Introduction, Mechanical Calibration - 1 
Mechanical Calibration (Cont.) – 2 
Electronic Calibration, Reassembly – 3 
Test Incline Operation - 4

 

   

   

 

1

 

Summary of Contents for 8100

Page 1: ...rtsArt 8100 Elliptical Trainer Incline Calibration Guide Table of Contents Introduction Mechanical Calibration 1 Mechanical Calibration Cont 2 Electronic Calibration Reassembly 3 Test Incline Operation 4 1 ...

Page 2: ...t operates but clicks replace a gear in the incline motor box or replace the whole incline set Incline Calibration Instructions Calibration of an 8100 incline set is just like the calibration of a treadmill incline set There are two parts one mechanical and one electronic Mechanical Calibration In mechanical calibration we set the incline motor to the mechanical 0 position 1 Take off covers by rem...

Page 3: ...motor in place Then pull out the motor 3 Remove the VR box from the incline motor as shown in Figure 3 4 Adjust the incline motor set mechanically as shown in Figure 4 Twist the thin pipe so that its red line is even with the end of the thick pipe This completes calibration to the mechanical 0 position Figure 2 Remove the motor Figure 3 Remove the VR box Figure 4 Calibrate mechanically 2 ...

Page 4: ...DC Probe into the blue and green VR wires while keeping them connected to the drive board and VR 7 Turn on unit power Turn the VR gear shown in Figure 6 to set the voltage at 1 20 VDC the electronic 0 setting This completes electronic calibration of the VR set Reassemble the Incline Set 8 Place the VR box on the incline motor as shown in Figure 7 Tighten the screws Figure 5 Connect VR wires Figure...

Page 5: ...RAMP window shows 0 The incline should operate to the lowest point The red line on the thin pipe should show above the end of the thick pipe on the incline motor 12 During incline operation inspect whether the drive board ERR LED lights If the unit has been calibrated properly but the ERR LED still lights and wires are secure the VR is malfunctioning Replace the VR box 13 If the motor jams or fail...