background image

S-ALU 220 UK

USER MANUAL

e

xpondo

.de

Summary of Contents for S-ALU 220 UK

Page 1: ...S ALU 220 UK USER MANUAL e x p o n d o d e ...

Page 2: ...rated for outdoor use and reduce the risk of electric shock PERSONAL SAFETY Stay alert Watch what you are doing and use common sense when operating a power tool Do not use a power tool while tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury Dress properly Do not wear loose clothing or jewelry Contai...

Page 3: ...t 10 meters around the work area Use a fire resistant material to cover or block all open doorways windows cracks and other openings c Enclose the work area with portable fire resistant screens Protect combustible walls ceilings floors etc from sparks and heat with fire resistant covers EN d If working on a metal wall ceiling etc prevent ignition of combustibles on the other side by mobbing the co...

Page 4: ... resulting in loss of power and overheating A 50 foot extension cord must be at least 12 gauges in diameter and a 100 foot extension cord must be at least 10 gauges in diameter If in doubt use the next heavier gauge The smaller the gauge number the heavier the cord PROVIDED EQUIPMENT Cable with mass clamp Cable with TIG burner WP 26 along with accessories Collets 1 6mm 2 4mm 3 2mm Ceramic nozzles ...

Page 5: ... the neutral gases as argon or helium or non oxidizable gas mixtures are used Welding with WIG method may be used for all welded metals Selection of the type of current polarization and curtain gas depends on the welded metal type This device uses the welding handle burner WIG which is equipped with the wolframic electrode argon curtain gas release nozzle and the fluxing agent depending on the wel...

Page 6: ... Breaker switch TIG WIG connector MMA connection Foot operated connector Mass conduit connector Gas air connection at the rear side of the welder 15 16 17 18 TIG WIG connector 19 20 21 22 Earthing at the rear side of each and every welder there is a bolt with earthing marking Before starting the device has to be earthed with the conduit which cross section can not be smaller than 6 mm It could pro...

Page 7: ... 90 Post gas s 1 10 Pulse frequency low frequency Hz 0 5 5 Base value current A 10 220 Start current A 10 220 End current A 10 220 Pulse current A 10 220 Arc ignition mode High frequency Efficiency 80 Duty cycle 60 Value of current A at 100 Duty Cycle TIG 170 MMA 170 Power factor 0 73 Class of insulation F IP protection IP21 EN EN CONNECTION DIAGRAMS TIG 1 TIG burner 2 workpiece 3 mass clamp 4 gas...

Page 8: ...Open the valve regulator of bottle with argon and switch on flow meter Gun switch key has to be pressed and you have to select an appropriate gas flow The inflow switch key has to be released and the gas inflow will be automatically stopped after several seconds In case of using the high frequency ignition the wolframic electrode has to be retracted 2 3 mm from the weld piece Next after switching ...

Page 9: ...nden Möglichkeiten der Rückgabe oder Sammlung von Altgeräten 1 RICHTLINIE 2002 96 EG DES EUROPÄISCHEN PARLAMENTS UND DES RATES ÜBER ELEKTRO UND ELEKTRONIK ALTGERÄTE 2 Gesetz über das Inverkehrbringen die Rücknahme und die umweltverträgliche Entsorgung von Elektro und Elektronikgeräten Elektro und Elektronikgerätegesetz ElektroG Umwelt und Entsorgungshinweise Utylizacja produktu Produkty elektryczn...

Reviews: