background image

Standard Pump

SPFP20 Models

• SPFP20NPT

• SPFP20NPS

• SPFP20SSS

• SPFP20SST

• SPFP20NPP

• SPFP20SSP

2" Food Processing

with Metallic Center Section

 SPFP20

STANDARD PUMP, INC

® 

 

1610 Satellite Blvd Suite D. Duluth, Ga. 30097

 • Phone: (770) 307-1003 • 

www.standardpump.com

THIS IS A PROPRIETARY DOCUMENT. DO NOT REPRODUCE OR DISCLOSE 

WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC.

 DESCRIPTION

 DRAWING NUMBER

WARREN RUPP INC.

 REV

02

E2SJxxxx9C-FP-ATEX

E2 FOOD PRO HYTREL FITTED 

PUMP

Service & Operating Manual

1: PUMP

 SPECS

2: INST

AL

 & OP

3: EXP

 VIEW

4: CERTIFICA

TES

Original Instructions

Summary of Contents for SPFP20

Page 1: ...FP20NPP SPFP20SSP 2 Food Processing with Metallic Center Section SPFP20 STANDARD PUMP INC 1610 Satellite Blvd Suite D Duluth Ga 30097 Phone 770 307 1003 www standardpump com Service Operating Manual 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 CERTIFICATES Original Instructions ...

Page 2: ... uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonmetallic pumps and plastic components are not UV stabilized Ultraviolet radiation can damage these parts and negatively affect material properties Do not expose to UV light for extended periods of tim...

Page 3: ...peration Typical Installation Guide Troubleshooting SECTION 3 EXPLODED VIEW 7 Composite Drawings Parts List Materials Code SECTION 4 CERTIFICATES 11 EC Declaration of Conformity Directive 2006 42 EC Machinery EC Declaration of Conformity Directive 94 9 EC ATEX EC Declaration of Conformity Directive 1935 2004 EC Food Contact Materials 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 CERTIFICATES ...

Page 4: ... excess of 5 NOTE Performance based on the following elastomeric fitted pump flooded suction water at ambient conditions The use of other materials and varying hydraulic conditions may result in deviations in excess of 5 Discharge Head in PSI 0 75 150 225 300 375 450 525 600 675 750 140 120 100 80 60 40 20 0 Capacity in Liters Per Minute Capacity in U S Gallons Per Minute Displacement Per Stroke 0...

Page 5: ...rifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures 220 F 104 C 35 F 37 C Maximum and Minimum Temperatures are the limits for which these materials can be operated Temperatures coupled with pressure affect the longevity of diaphragm pump components Maximum life should not be expected at the extreme limits of the temperature ranges Metals Stainless Steel Eq...

Page 6: ... drawing can be requested if physical dimensions are needed Dimensional Drawings 17 18 436 32 3 03 76 96 O D TRI CLAMP DISCHARGE PORT 1 72 43 64 3 03 76 96 O D TRI CLAMP SUCTION PORT 9 39 238 48 19 42 493 34 24 72 627 86 1 00 25 40 RUBBER FOOT 1 2 NPT AIR INLET 1 NPT AIR EXHAUST 26 22 665 96 38 9 53 3 00 76 20 13 62 345 95 9 00 228 60 10 00 254 00 12 50 317 50 11 50 292 10 2 50 63 50 RUBBER FOOT 1...

Page 7: ...ion side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pulled through its stroke The diaphragm s inner plate makes contact with an actuator plunger aligned to shift the pilot signaling valve Once actuated the pilot valve sends a pressure signal to t...

Page 8: ...ater in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to increase air flow as desired If opening the valve increases cycling rate but does not increase the rate of flow cavitation has occurred The valve should be closed slightly to obtain the most efficie...

Page 9: ...olds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure 2 1 units Cavitation on suction side Check suction move pump closer to product Lack of air line size PSI CFM Check the air line size length compressor capacity Excessive suction l...

Page 10: ...34 39 24 26 27 28 VERSA DOME DIAPHRAGM ASSEMBLY 01 REV OE TO REV C MAV REV REVISION CHG DATE APP DATE ECN THIS IS A PROPRIETARY DOCUMENT DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC DESCRIPTION DRAWING NUMBER WARREN RUPP INC REV 01 E2SJxxxx9C FP ATEX E2 FOOD PRO HYTREL FITTED PUMP Torque to 480 in lbs Torque to 480 in lbs Torque to 275 in lbs Torque to 60 ...

Page 11: ...23 200 227 200 239 200 221 200 217 17 1 Pilot Sleeve Assembly include item 18 18 6 O Ring 19 1 Retaining Ring 20 1 Pilot Spool Assembly Includes item 21 21 7 O Ring 22 1 Muffler Diaphragm Assembly Elastomers Item Qty Description Part Number Model SPFP20NPS Model SPFP20SSS FDA Santoprene FDA Santoprene 23 1 Main Shaft 200 272 200 397 200 394 24 2 Diaphragm 25 2 O Ring 26 2 Inner Diaphragm Plate 200...

Page 12: ...7 Composite Repair Parts Drawing PTFE Fitted 40 26 24 28 2 3 4 5 6 7 8 9 1 1 11 12 15 16 17 18 19 20 21 22 14 24 26 27 25 30 32 33 34 37 38 40 23 35 36 41 28 29 39 13 45 47 43 44 46 47 FUSION DIAPHRAGM ASSEMBLY 24 25 28 METAL SEAT ASSEMBLY 29 25 30 Y Torque Setting 275 in lbs 31 1 N m Torque Setting 480 in lbs 54 2 N m 600 in lbs 67 8 N m For XL Material ONLY Torque Setting 60 in lbs 6 78 N m 3 EX...

Page 13: ...aining Ring 20 1 Pilot Spool Assembly Includes item 21 21 7 O ring 22 1 Muffler Diaphragm Assembly Elastomers Item Qty Description Part Number Model SPFP20NPT Model SPFP20NPP Model SPFP20SST MODEL SPFP20SSP 23 1 Main Shaft 200 273 200 396 N A 200 436 200 456 200 457 200 273 200 396 N A 200 436 200 456 200 457 24 2 Diaphragm 40 2 Back Up Diaphragm 25 2 O Ring 200 425 26 2 Inner Diaphragm Plate N A ...

Page 14: ...ALTUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMITÀ CONFORMITEITSVERKLARING DEKLARATION OM ÖVERENSSTÄMMELSE EF OVERENSSTEMMELSESERKLÆRING VAATIMUSTENMUKAISUUSVAKUUTUS SAMSVARSERKLÄRING DECLARAÇAO DE CONFORMIDADE STANDARD PUMP INC 1610 Satellite Blvd Suite D Duluth GA 30097 USA Tel 770 307 1003 This product has used the following harmonized standards to verify conformance Ce materiel est fabriqué s...

Page 15: ...97 USA On File With DEKRA Certification B V 0344 Meander 1051 6825 MJ Arnhem The Netherlands Harmonized Standards Applied BS EN 13463 1 2009 Non Electrical Equipment Potentially Explosive Atmospheres Part 1 Basic Methods and Requirements EN 13463 5 2011 Non Electrical Equipment for Potentially Explosive Atmospheres Part 5 Protection by Constructional Safety Equipment SPFP20 SPFP30 SPSN20 SPFP15 SP...

Page 16: ...od Contact Materials Signature of authorized person Revision Level B Printed name of authorized person Chris Murphy Director of Operations October 13 2015 Date of issue September 11 2013 Title Date of revision SPFP05PPS SPFP10PPS SPFP15NPS SPFP20NPS SPFP20SSS SPFP30NPT SPFP30SST SPFP30NPS SPFP30SSS SPFP05PPP SPFP10PPP SPFP15NPP SPFP20NPP SPFP20SSP Food Processing Pump Models SPSN15NPS SPSN20NPS SP...