Stanley Omnilock
a Product Group of Stanley Security Solutions, Inc.
9KOM Extreme Weatherized Cylinder Locks
This addendum begins after step 6 of
Installation Instructions for Stanley Omnilock 9KOM Cylinder Locks T83303.
1 From the outside of the door, insert the lock chassis and outside escutcheon into the 2 1/8” (54 mm) chassis
hole.
2 Make sure that the latch tube prongs engage the chassis frame and that the latch tailpiece engages the
retractor. See .
3 Thread connecting cables and grounding wire through the door cable hole. Use screws to attach the
module bracket from the inside of the door. See Figure 2.
Note:
Ensure that no wires are pinched when attaching the escutcheon to the door.
4 Connect the batteries and wires as shown in Figure 3.
5 Secure the extreme weather module cover with the security screws provided. See Figure 4.
6 Continue with step 10 of the
Installation Instructions for Stanley Omnilock 9KOM Cylindrical Locks (T83303)
to
finish installation.
Chassis
Figure 1
Installing the lock chassis and engaging
the retractor in the latch
Latch tube
prong
Retractor
Latch
tailpiece
Chassis frame
Latch tube
prong
Grounding
wire
Wire inlet
Module
Figure 2
Inside circuit module
Connecting
cables
bracket
Figure 3
Wire connections to circuit module
10 Pin
Connector
Grounding
wire
12 Pin
Connector
Cover
grounding
Wire inlet
wire
Security
screws
Figure 4
Inside view of weatherized model
Installation Addendum for
Stanley Omnilock 9KOM
Extreme Weatherized Locks
T83319/Rev A 0000000 ER-7991-12 Jan 2010