THERMAL REWRITE CARD

READER / WRITER

TCP100/2000 series

Installation Guide & Specifications

Thank you for choosing the TCP100/2000 Thermal rewrite card system.

This “Installation Guide & Specifications” includes very important

 instructions for safety.

Please read this manual before you start the system,

and follow the instructions.

Star Micronics Co., Ltd.

Special Products Operating Division

Summary of Contents for TCP100 Series

Page 1: ...ank you for choosing the TCP100 2000 Thermal rewrite card system This Installation Guide Specifications includes very important instructions for safety Please read this manual before you start the sys...

Page 2: ...C O N T E N T S 1 HANDLING NOTES 1 2 OUTLINE 4 3 UNPACKING 5 4 APPEARANCE AND NOMENCLATURE 6 5 CONNECTION TO EXTERNAL UNITS AND SETTING 7 6 CLEANING 8 7 TROUBLE SHOOTING 9 8 GENERAL SPECIFICATIONS 10...

Page 3: ...er writer away from magnetic sources to avoid erasing or damaging data stored on card 8 Do not use the power supply in the unspecified range This may cause generation of heat electric shock malfunctio...

Page 4: ...4 Do not leave the card in high temperatures such as inside of the car It may cause the bend of card or erase the printed data on the card 5 Do not insert bent card into the TCP100 2000 reader writer...

Page 5: ...east for one hour before re start 14 Do not use the TCP100 2000 reader writer under dew condensation It may cause malfunction failure electric shock etc 15 Clean the TCP100 2000 reader writer everyday...

Page 6: ...epends on the model type 2 Reads writes data from to IC chip on the card TCP100 series only depends on the model type 3 Prints erases characters graphics to from a human readable area 4 Serial interfa...

Page 7: ...ing the unit check that all the accessories are included in the individual box Housed unit TCP100 2000 series 1 TCP100 2000 unit 2 Power cable 3 Cleaning cards 2 pcs 4 Cleaning liquid 5 Installation G...

Page 8: ...or e g jamming of the card in the reader writer 7RS232C Serial Connector This connector interfaces the connection between host computers and the reader writer 8 AC Power Inlet Connect this inlet to th...

Page 9: ...e Please set the interface convert switch to the left side Note Do not connect to any external devices other than MCD2000 TCP100 TCP2000 Serial Interface RS 232C 1 Applicable connector D sub 9 pin fem...

Page 10: ...d write errors occur continuously or print quality gets low 3 How to use 1 Open the Front Cover and push the Cleaning Switch 2 Apply penetration of the cleaning liquid to the felt surfaces both sides...

Page 11: ...Flaw or bend of card loss of card data using other user s card Head is stained System does not properly run Trouble with the main unit Properly plug in power cable Consult technical support Use applic...

Page 12: ...ha numeric standard Chinese characters option Graphics Font configuration 12 24 24 24 48 24 12 24 24 24 48 24 dots 24 48 48 24 24 48 48 48 8 16 16 16 32 16 16 32 32 32 Dot pitch 0 1mm Vertically 0 125...

Page 13: ...Special Products Operating Div Card System Sales Section 536 Nanatsushinya Shimizu 424 0066 Japan Tel 81 543 47 0122 Fax 81 543 48 5013 http www star micronics co jp 2000 07 59082055...