background image

3500W Digital 

Generator

SP-GG350D

Thank you for purchasing our generator.
This manual covers the operation and maintenance of the generator.
All the information in this publication is based on the latest product information available at the
time of approval for printing.
We reserve the right to make changes to this manual at any time without notice and obligation 
whatsoever.
No part of this publication may be reproduced without written permission from All-Power America.
This manual should be considered a permanent part of the generator and should remain with it 
when being resold.
Pay special attention to statements preceded by the following words: 

PREFACE

Failure to properly follow these precautions can result in property damage,  
serious injury or DEATH!
Read all labels and the owner's manual before operating this generator. 
Operate only in well ventilated areas. Exhaust gas contains poisonous carbon 
monoxide, and can be deadly. 
Always stop the engine before refueling.Wait 5 minutes before restarting. 
Check for spilled fuel or leaks. Wait 5 minutes before use.
Keep any sources of ignition away from fuel tank at all times. 

Indicates a strong possibility of severe personal 
injury or death if instructions are not followed.

Indicates a possibility of personal injury or equipment damage if instructions 
are not followed.
NOTE:Gives helpful information.
If a problem should arise or if you have any questions about the generator,
consult an authorized dealer. 

3500W Digital Generator

1

Our generators are designed to give safe and dependable service if operated 
according to instructions. Read and understand the Owner's Manual before  
operating the generator. 
Failure to do so could result in personal injury or equipment damage.

CONTENTS

1

SAFETY INSTRUCTIONS ------------------------------------------------------------------------------------3

2

SAFETY LABEL LOCATIONS -------------------------------------------------------------------------------5

3

PRE-OPERATION CHECK -----------------------------------------------------------------------------------8

4

STARTING THE ENGINE -----------------------------------------------------------------------------------11

5

USING THE GENERATOR ---------------------------------------------------------------------------------14

6

STOPPING THE ENGINE ----------------------------------------------------------------------------------17

7

MAINTENANCE -----------------------------------------------------------------------------------------------18

8

TRANSPORTING/STORAGE ------------------------------------------------------------------------------23

9

TROUBLESHOOTING ---------------------------------------------------------------------------------------24

10 SPECIFICATIONS --------------------------------------------------------------------------------------------26

11 WIRING DIAGRAM -------------------------------------------------------------------------------------------27

12 WHEEL KIT -----------------------------------------------------------------------------------------------------28

13 Part List ----------------------------------------------------------------------------------------------------------29

14 WARRANTY ----------------------------------------------------------------------------------------------------32

Owner’s Manual

2

1.SAFETY INSTRUCTIONS

Our generators are designed to give safe and dependable service if 
operated according to instructions. Read and understand the owner's  
manual before operating the generator. Failure to do so could result in
personal injury or equipment damage.

Exhaust gas contains poisonous contents (eg. carbon monoxide). 
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.

The muffler becomes very hot during operation and remains hot for a 
while after stopping the engine. Be careful not to touch the muffler while
it is hot. Let the engine cool before storing the generator indoors. 
The engine exhaust system will be heated during operation and remain 
hot immediately after stopping the engine.
To prevent scalding, pay attention to the warning marks attached to the 
generator.

Never connect a cable other than the special cable for parallel operation 

to the parallel operation socket. 

Electric shocks can result if this instruction is not followed.

3500W Digital Generator

3

Summary of Contents for SP-GG350D

Page 1: ...onsult an authorized dealer 3500W Digital Generator 1 Our generators are designed to give safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage CONTENTS 1 SAFETY INSTRUCTIONS 3 2 SAFETY LABEL LOCATIONS 5 3 PRE OPERATION CHECK 8 4 STARTING THE ENGINE...

Page 2: ...arter grip Control panel Fuel filler cap Air intake hole Front cover LCD screen Operation button Side cover 3500W Digital Generator 5 2 2 Control pannel Fig 2 Control panel ON Engine speed is kept at economical state automatically to minimize the fuel consumption while in operation This position is recommended when the output power is less than 1 kW 2 3 ECON switch When high electrical load applia...

Page 3: ... refueling tighten the fuel filler cap securely Fig 5 Oil surface E F Loosen Tighten 3500W Digital Generator 9 Gasoline containing alcohol If you decide to use a gasoline containing alcohol gasohol be sure its octance rating is at least as high as being recommended by us There are two types of gasohol one containing ethanol and the other containing methanol Do not use gasohol that contains more th...

Page 4: ...during a power outage and when utility power is restored the generator may explode burn or cause fires in the building s electrical system Limit operation requiring maximum power to 30 minutes For continuous operation do not exceed the rated power In either case the total wattage of all appliances connected must be considered Do not modify or use the generator for other purposes than it is intende...

Page 5: ...tal Generator 17 7 MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated The exhaust contains poisonous gases Use our genuine parts or the equivalent The use of replacement parts which are not of equivalent quali...

Page 6: ...cover and tighten the cover screw 10 Close the access door Plug gap The spark plug must be securely tightened An improperly tightened spark plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 3500W Digital Generator 21 7 5 Spark arrester maintenance If the generator has been running the muffler will be very hot Allow it to cool before proce...

Page 7: ...cuit Switch on the DC output Replace the DC circuit fuse Take the generator to an authorized dealer NO YES NO Is the operation indicator light ON Is the short circuit indicator light ON Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the electrical ap...

Page 8: ...r 27 APG3104 28 BOLD Fuel tank 28 APG3104 29 BOLD Bolt 29 APG3104 30 BOLD Handle 30 APG3104 31 BOLD Bolt 31 APG3104 32 BOLD Sealing ring 32 APG3104 33 BOLD Start grip 33 APG3104 34 BOLD Bolt 34 APG3104 35 BOLD Ring cover 35 APG3104 36 BOLD Frame 36 APG3104 37 BOLD Bolt 37 APG3104 38 BOLD Fuel switch 38 APG3104 39 BOLD Oil alert lamp 39 APG3104 40 BOLD Engine switch 40 Owner s Manual 30 APA Part No...

Page 9: ...t costs if any must be paid by the purchaser If the purchaser does not receive satisfactory results form the Authorized Warranty Service Center the purchaser should contact Steele toll free 888 896 6881 THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned used as rental equipment or floor or display models Merchandise that has become damaged or inoperative because of ordinary wear misuse...

Reviews: