background image

Toll Free: 800-888-4784 • E-mail: info@sti-usa.com
Web: www.sti-usa.com

USA - Headquarters

2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246

Tel: 44 (0) 1527 520 999   Fax: 44 (0) 1527 501 999 
E-mail: info@sti-emea.com • Web: www.sti-emea.com 

European Office

Taylor House • 34 Sherwood Road • Bromsgrove
Worcestershire • B60 3DR • England 

ID_SS2_02_05_08_09_Rev0919

INSTALLATION OF SS-2xx2, 2xx5, 2xx8 and 2xx9 SERIES STOPPER

®

STATION

All specifications and information shown were current as of publication and are subject to change without notice.

Safety Notice to Installers and Users 

SS2xx2, SS2xx5 & SS2xx9 models

This push button has been tested according to UL2017. It is important to read, understand and follow all instructions provided with this product. Non-

fire alarm initiating devices are listed in UL category UEHX. It is the installer’s responsibility to comply with NEC and Canadian electrical code, mounting 

specifications according to ADA and other applicable fire and electrical codes. To avoid electrical shock, DO NOT attempt to install this product when 

power is on. To avoid possible confusion with fire alarm initiating devices, do not mount a red stopper station near a manual fire alarm initiating device. 

ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 1/2 ft.) or greater than 1.37m (4 1/2 ft.) above 

finished floor service. After installation and testing are complete, provide a copy of this manual to all personnel responsible for testing and maintenance 

of this product. Push buttons for outdoor use must be mounted with STI outdoor rated covers.

SS2xx8 models

This push button has been tested according to UL2017. Non-fire alarm initiating devices are listed in UL category UEHX. It is important to read, 

understand and follow all instructions provided with this product. It is the installer’s responsibility to comply with NEC, Canadian Electrical Code, 

mounting specifications according to ADA and other applicable fire and electrical codes. After installation and testing are complete, provide a copy of 

this manual to all personnel responsible for testing and maintenance of this product. To avoid electrical shock, DO NOT attempt to install this product 

when power is on. 

Note:

 To reduce potential risk, STI discourages use of a pneumatic timer button as an emergency power disconnect or any control 

that may restart automatically at the end of the timing sequence.

NOTE

 For LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A, the enclosed timer is to be used and installed per the enclosed LT-1UL 

installation sheet. LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A maximum rating 30 VDC 3A. For access control installations, power 
for the LT-1 Timer must be supplied by a power source listed to UL294.  When used for access control, this device shall be used as part of an access 
controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, 
lower time limits should be used.

ADA

Compliant

ADA

Compliant

Housing Removal

PULL BOTTOM OF HOUSING OUT AND LIFT UP UNTIL TABS ARE 
RELEASED FROM SLOTS IN TOP OF SWITCH ASSEMBLY.

ONCE INSTALLATION IS COMPLETE, SECURE COVER WITH 
SCREW AND HEX WRENCH (SHOWN).

3/32” HEX WRENCH
(1) PROVIDED

ALLEN HEAD SCREW

#8-32 x 3/8 in.

(1) PROVIDED

SWITCH HOUSING

BUTTON AND SWITCH ASSEMBLY

WHITE

BLACK

GREENRED

INSULATING

BUSHING

 SCREW #6-32 x 1 in.

(2) PROVIDED

BUTTON CAP

(PUSH SHOWN)

 SCREW

#6 x 1-1/4 in.

(4) PROVIDED

BUTTON AND SWITCH ASSEMBLY

RAWL PLUGS

(4) PROVIDED

DRILL (4)

3/16 in. DIA. HOLES

OPTIONAL SURFACE

MOUNT BACK BOX

KIT-71100A-*COLOUR*

DRILL POINT LOCATION PROVIDED TOP AND BOTTOM

FOR CONDUIT FITTINGS. DRILL AS NEEDED.

BUTTON ILLUMINATION

*

ASSEMBLY

BUTTON CAP

ALIGNMENT HOLE

BUTTON ILLUMINATION WIRES*

NOTE

ADA MOUNTING COMPLIANCE REQUIRES THE OPERABLE 
PART OF THE INITIATING DEVICE SHALL NOT BE LESS THAN 
1.1 m (3 ½ ft.) OR GREATER THAN 1.37m (4 ½ ft.) ABOVE 
FINISHED FLOOR SURFACE.

Installation

*

BUTTON ILLUMINATION WIRING

12-24 VAC/VDC, 21mA EACH COLOR
BLACK - GROUND
WHITE - WHITE LED (+)
GREEN - GREEN LED (+)
RED - RED LED (+)

Product Dimensions

PRODUCT DIMENSIONS

25mm

(1 in.)

82mm

(3.22 in.)

123mm

(4.86 in.)

CO
M

NO

NC

41mm

(1.62 in.)

40mm

(1.58 in.)

DIMENSIONS WITH

KIT-71100A-*COLOUR*

DIMENSIONS WITH

KIT-102720-*COLOUR*

1.62 in.

(41mm)

1.58 in.

(40mm)

MODELS WITH

OPTIONAL BACK BOX

41mm

(1.62 in.)

41mm

(1.62 in.)

25mm

(1 in.)

CO
M

NO

NC

12mm

(.47 in.)

On Site Button Reconfiguration         

Stopper Station button is configured as ordered.  If needed, installer can 
reconfigure function to: Key-to-Reset, Momentary or Turn-to-Reset.

Changing Push Button Function

1.  Remove contact block screws from 

mounting plate.

2.  To change button function remove the 

plate and use directions provided.

3.  Reassemble backplate and contact 

box (ensure contact tabs are facing up 
as shown).

4.  If reconfiguring from Turn-to-Reset, 

remove Turn-to-Reset label. 

Note: If you remove stop pin and wedge 

block, consider keeping for potential 
future use.

REMOVE SCREWS,
MOUNTING PLATE
AND SWITCH ASSEMBLY

MOUNTING PLATE

SWITCH ASSEMBLY

CAUTION

DO NOT

REMOVE

CONTACT TABS

ATTENTION

NE PAS ENLEVER

Wire Connections

 

CONTACT

SET 1

CONTACT

SET 2

CONTACT BOX CONTAINS

TWO CONTACT SWITCHES

NC

NO

NC

NO

COM

COM

NO NC

CO

M

9 in. QUICK CONNECT WIRE LEAD

(6) PROVIDED

MAKE SURE LEAD IS

FULLY CONNECTED TO

MOUNTING TAB

Reviews: