Summary of Contents for AML+

Page 1: ...SUBSURFACE INSTRUMENTS INC AML OPERATOR S MANUAL www ssilocators com ...

Page 2: ...the sealed case will void the warranty If maintenance tuning or repair becomes necessary contact SubSurface Instruments Inc email info ssilocators com Telephone 920 347 1788 or Or by mail SubSurface Instruments Inc 1230 Flightway Drive De Pere WI 54115 USA AML SAFETY INFO READ OBSERVE ALL INSTRUCTIONS Save these instructions for future reference 2 Proudly Made in the USA ...

Page 3: ...ser beam especially with optical instruments such as binoculars or magnifiers can permanently damage the eye This is a professional tool not a toy It should not be used by children OPERATION Only use this equipment for the purpose specified by the manufacturer Any misuse may void the warranty READ OBSERVE SAFETY WARNINGS Save these instructions for future reference D F I ish man ch an 3 ...

Page 4: ...change in conductivity density and or permeability from surrounding materials This causes a distortion in the return signal detected by the UHF receivers on the sides of the AML and is interpreted by the advanced microprocessor circuit board technology OPERATING INSTRUCTIONS User Reference Scanning QR Codes AML reference videos and instructions can be accessed from your smart phone using a standar...

Page 5: ...ue de la Classe B est conforme à la norme NMB 003 du Canada This device complies with RSS 210 of Industry Canada This Class B device meets all the requirements of the Canadian interference causing equip ment regulations Cet appar eil numérique de la Classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada FCC IC CE STATEMENTS CE Approved European Countries European ...

Page 6: ...CONTROLS AND FUNCTIONS 1 2 3 4 5 6 7 8 10 9 Backside view of unit 11 6 ...

Page 7: ...and laser target indicators work in unison with the right and left LEDs to alert the operator of an object s presence and to place its location 5 LED POWER INDICATOR The power indicator LED emits a bright green light when the unit is ON This LED also serves as the battery life indicator and flashes green and red when battery power is low 6 LIGHTWEIGHT DURABLE CONSTRUCTION The electronic circuitry ...

Page 8: ...headphone port for operation in noisy environments if necessary 11 USB PORT The USB Port has several functions such as connecting the auxiliary external lithium battery supply to the USB Port for extended power and for uploading or downloading diagnostic information The lithium battery pack will provide a minimum of 20 hours of continuous usage before needing to be re charged There are several USB...

Page 9: ...GPR radar The AML has nine sensitivity settings with setting 9 being the strongest see figure 9 1 However the density of the material will influence the depth of the transmitted signal The transmission signal will penetrate deeper through highly reflective materials such as concrete clay asphalt or highly compacted soil see figure 9 2 and less deep in sand granular soil or recently backfilled soil...

Page 10: ... false readings Hold the handle parallel to the ground at waist level and 18 to 24 inches out in front of the body The blade of the unit is designed with a 10º degree outward projection to help eliminate false readings from interference with the operator s feet see Figure 10 1 When an object is detected the left and right LED target indicators will illuminate an audio tone will sound and the laser...

Page 11: ...ound and directly above the area of the signal see figure 11 2 You can now scan the ground in parallel for the entire length of the object identifying its diameter or width location and run direction as you track the object Note Read the Safety Notes section pages 3 4 before operating your AML 11 10 Figure 11 2 Locating Position Tilt the handle forward 10º when locating the exact edge of an object...

Page 12: ...rk the ground 2 Tilt the AML to a 45º angle 3 Start walking backwards until you find the pipe again Make sure you located the pipe by scanning its edge 3 to the right or left 4 Mark the spot on the ground 5 The distance between both points is the depth of the pipe 1 2 3 4 5 2 3 4 5 On the AML your can use a level application in your smart phone Useful Tip if you tilt the handle downward until the ...

Page 13: ...n handling the wiring harness 4 Reinsert the battery sleeve into the handle silver lead end first 5 Replace battery access cap Note One battery sleeve is included with each unit Each battery sleeve uses three 3 9 volt industrial grade alkaline batteries For best results and longer battery life use only industrial grade 9 volt batteries Additional or replacement battery sleeves are available by ema...

Page 14: ...power or 40 hours at average industry usage Lithium Rechargeable Battery Pack Provides over 20 hours of continuous usage and cellphone recharging or over 150 hours of use at average industry usage Shipping Dimensions Cube 20 l x 17 w x 8 h 50 8cm x 43 18cm x 20 32cm Weight 17 lbs 7 7kg Includes 1 AML Unit 1 Battery Pack Housing 3 9 Volt Batteries 1 Lithium Rechargeable Battery Pack with Battery Ch...

Page 15: ...a exe file to the desktop for easy access 4 This is a very simple application once you have the file on your desktop it is ready for use Note After completing the firmware update process your unit will need to be recalibrated use the AML Customer Utility to calibrate the AML and to run diagnostics requested by the manufacturer Updating the Firmware on the AML 1 Connect the AML to your computer wit...

Page 16: ...e 16 1 4 The computer will automatically recognize the Comm Port the AML is connected The port will appear in the left panel of the screen 5 Select your file source by clicking on Browse button select latest firmware file and click OK 6 Go over the configuration settings in all tabs compare the values with the values in page 17 make sure they match 7 On the left panel click Write Flash This will s...

Page 17: ...itter Char Rx Reciever Char dump bin Options ID code C1h Normal Reset Active RTS DTR ON Codes to send first 24h 49h Search Delay 7 Timeout ms 300 Search for COMs Active TermOpt Graphic 2 reference 128 Xaxis compression 1 Click Write Flash to start Upon completion a message WRITE OK will display 17 ...

Page 18: ...ompress software you can go to http www winzip com win en downwz html to download a free version 3 Double click the SETUP AML PLUS CAL V1r3 exe and follow the instructions on the screen 4 The Installation will create a shortcut on your computer s desktop for quick access to the calibration process in the future Note The calibration process must be performed outdoors with the AML plugged into the c...

Page 19: ... the AML unit figure 19 1 4 Type a to start the calibration process and press enter a confirmation prompt will display type y to confirm and press enter to start the process remember to have the AML pointing to an unobstructed sky at this point APPENDIX Figure 19 1 Figure 19 2 19 ...

Page 20: ...are displayed after the calibration is complete This information will be helpfull when troubleshooting with a SSI Technician For end user calibration needs the proccess is finished and the AML is ready to be used 6 Test your AML unit on the field for proper operation If you have any questions or concerns contact SSI at info ssilocators com Figure 20 1 20 ...

Page 21: ...ial from the use non use misuse improper or proper use of this or any product designed manufactured and or distributed by SubSurface Instruments Inc Locating accuracy and safety all encompassed are the sole responsibility of the Operator user of the product DISCLAIMER SubSurface Instruments Inc is not responsible for errors and or omissions in this manual Information in this manual is subject to c...

Page 22: ...use physical or chemical harm to the unit therefore this shall be considered abuse also SubSurface Instruments Liability under this warranty is absolutely limited to repair service or replacement of the product at the sole discretion of SubSurface Instruments Inc No other warranty is expressed or implied Failure to register your AML within 30 days of receipt will void the warranty Any unit suspect...

Page 23: ...SubSurface Instruments Inc 920 347 1788 phone 920 347 1791 fax 855 422 6346 855 I can find it info ssilocators com www ssilocators com Rev 11 2019 Proudly Made in the USA Your Local Dealer ...