background image

SUBURBAN GAS FURNACES

 

INSTALLATION INSTRUCTIONS FOR

SF-20FQ • SF-25FQ • SF-30FQ • SF-35FQ • SF-42FQ

The design of the furnace has been listed for installation in recreational vehicles only. In order for the furnace to operate in conformity with generally 

accepted safety regulations, the installation instructions must be followed. Failure to comply with the installation instructions will void the warranty 

on the furnace and any responsibility on the part of Suburban Manufacturing Company.

The furnace was inspected before it left the factory. If any parts are found to be damaged, do not install the furnace. Immediately contact the 

transportation company and file a claim.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:

• 

Extinguish any open flame.

• 

Evacuate all persons from the vehicle.

•  Shut off the gas supply at the gas container 

or source.

•  Do not touch any electrical switch, or use 

any phone or radio in the vehicle.

•  Do not start the vehicle’s engine or electric 

generator.

•  Contact the nearest gas supplier or 

qualified service technician for repairs.

•  If you cannot reach a gas supplier or 

qualified  service  technician,  contact  the 

nearest fire department.

•  Do not turn on the gas supply until the gas 

leak(s) has been repaired.

This book contains instructions covering the operation and 

maintenance of your furnace.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
Should  you  require  further  information,  contact  your  dealer  or 

nearest Suburban Service Center.

 

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER 

FLAMMABLE VAPORS AND LIQUIDS IN THE 

VICINITY OF THIS OR ANY OTHER APPLIANCE.

WARNING!

 

Improper installation, adjustment, alteration, 

service or maintenance can cause property damage, personal 

injury or loss of life. Refer to the installation instructions and/

or owners manual provided with this appliance. Installation 

and service must be performed by a qualified installer, service 

agency or the gas supplier.

WARNING!

 

Be sure the furnace and all ignition systems 

are “OFF” during any type of refueling and while vehicle is in 

motion or being towed.

INSTALLATION INSTRUCTIONS

WARNING!

 

Installation of this appliance must be made in accordance with the written 

instructions provided in this manual. No agent, representative or employee of Suburban or 

other person has the authority to change, modify or waive any provision of the instructions 

contained in this manual.

THESE FURNACES ARE DESIGNED AND INSTALLED IN SUCH A MANNER 

AS TO BE REMOVABLE ONLY FROM WITHIN LIVING AREA OF THE 

RECREATIONAL VEHICLE.

IF UNIT IS TO BE INSTALLED VERTICALLY, YOU MUST USE KIT #520965 

(INSTALLATION INSTRUCTIONS ARE ENCLOSED IN KIT).

CAUTION: If possible, do not install the furnace to where the vent can be 

covered or obstructed when any door on the trailer is opened. If this is not 

possible, then the travel of the door must be restricted in order to provide 

a 6” minimum clearance between the furnace vent and any door whenever 

the door is opened. 

NOTE

: The exhaust temperature of this furnace could discolor or warp some 

materials. You should verify that the material used on the coach door, panel, or 

cover will not discolor or warp from the exhaust temperature whenever any door, 

panel, or cover is in the open position.

CAUTION: Due to the differences in vinyl siding, this appliance should not 

be installed on vinyl siding without first consulting with the manufacturer 

of the siding or cutting the siding away from the area around the appliance 

vent.

CAUTION: In any installation in which the vent of this appliance can be 

covered due to the construction of the RV or some special feature of the 

RV such as slide out, pop-up etc. always insure that the appliance cannot 

be operated by setting the thermostat to the positive “OFF” position and 

shutting  off  all  electrical  and  gas  supply  to  the  appliance.  Never  operate 

furnace with vent covered.

NOTE

: These furnaces must be installed and vented as described in this manual 

so that the negative pressure created by the air circulating (return air) fan cannot 

affect the combustion air intake or venting of any other appliance. It is imperative 

that the products of combustion be properly vented to the atmosphere and that all 

combustion air supplied to burner be drawn from the outside atmosphere. (See 

Installing Vent Assembly.)

NOTE: Do not install the furnace with the vent facing toward the forward end 

of the coach.  

See figures 7 and 8.

IMPORTANT

: If this furnace is to be connected to a common duct system also 

serving a cooling unit, a manual or automatic damper is required to prevent any 

cold conditioned air from circulating back into the furnace. Cold air passing over 

the furnace combustion chamber during the operation of the cooling unit can result 

in the formation of condensation inside the furnace combustion chamber. This 

condensation may promote corrosion and premature failure of the combustion 

chamber.

NOTE

: These furnaces shall be installed so the electrical components are 

protected from water.

These furnaces are design certified for propane/LP gas only. Do not attempt to 

convert to natural gas.

Gas supply pressure for purposes of input adjustment:

 

Minimum - 11” W.C.*  Maximum - 13” W.C. *

(W.C.* - Water Column).

Part Number 205170

01-06-2015

AIRXCEL, INC. - SUBURBAN DIVISION

676 Broadway Street 

Dayton, Tennessee   37321

423-775-2131

www.AIRXCEL.com

Summary of Contents for SF-20FQ

Page 1: ...TO BE INSTALLED VERTICALLY YOU MUST USE KIT 520965 INSTALLATION INSTRUCTIONS ARE ENCLOSED IN KIT CAUTION If possible do not install the furnace to where the vent can be covered or obstructed when any...

Page 2: ...nting of furnace exhaust 5 After determining x dimension complete the furnace installation as follows A IF INSTALLED DIRECTLY AGAINST OUTER SKIN OR X DIMENSION IS 0 1 1 2 1 Vent Kit 520767 must be ord...

Page 3: ...e output to return leg when there is not a call for heat or in the OFF setting Locate the room thermostat approximately 4 1 2 feet above the floor on an inside bulkhead where it is not affected by hea...

Page 4: ...Turn the manual valve if so equipped or the valve at the outside LP tank to the OFF position Do not force 3 Set thermostat above room temperature to begin blower operation A slight delay will occur be...

Page 5: ...P AND EXHAUST TUBE INTAKE AIR WITH GASKET OUTSIDE SKIN PANEL Figure 1 SF 20FQ SF 25FQ SF 30FQ SF 35FQ SF 42FQ STANDARD VENT INSTALLATION X INTAKE 1 2 MINIMUM OVERLAP EXHAUST 1 1 4 MINIMUM OVERLAP 2 3...

Page 6: ...GREEN ALL WIRES ARE 18 AWG UNLESS OTHERWISE SPECIFIED IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING...

Page 7: ...M THE CABINET AND THE MANIFOLD BLOWER ASSEMBLY AND CONTROLS REMO VED LEAVING THE CHAMBER ONLY AS SHOWN USING COMPRESSED AIR B LOW THROUGH THE CHAMBER AS SHOWN BY ARROWS TO REMOVE SOOT OR LOOS E DEBRIS...

Page 8: ...TIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH EACH LIMITED WARRANTY IS GIVEN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED W...

Page 9: ...iqu es pour la garantie de deux ann es L EXCEPTION que Suburban ne remboursera aucun frais de main d oeuvre LIMITATION DES GARANTIES LA P RIODE DE VALIDIT DES GARANTIES IMPLICITES CECI INCLUANT LES GA...

Page 10: ...alement le ventilateur et les organes de commande il ne doit rester que la chambre de combustion comme on le voit sur l illustration Injecter de l air comprim dans la chambre selon les indications des...

Page 11: ...DE COURSE N C CONTACTEUR DE Y Y Y BR BK MOTEUR L INTERRUPTEUR EN MARCHE ARRET N C BL BK BK Y BR R Y O R BL WH POUVOIR DE THERMOSTAT R 12 V D C Y 12 V D C BL THERMOSTAT FR340571 12 VOLTS D C R CLAPET...

Page 12: ...G N REUSEMENT AUTOUR DU P RIM TRE DU COUVERCLE DU SYSTEME D ADMISSION ET DE D CHARGE D AIR ET SUR LA LIGNE DE CENTRE COMME INDIQU LE CALFATAGE DE LA LIGNE DE CENTRE EST ESSENTIEL D TAIL A TUBE D ADMIS...

Page 13: ...nt la chambre la caisse 3 R installer le panneau avant de la caisse 4 Connecter la source de gaz 5 Inspecter les connexions de la canalisation de gaz Rechercher les fuites avec une solution savonneuse...

Page 14: ...e sur la plaque signal tique INSTALLATION DU THERMOSTAT Le thermostat utilis avec cet appareil ne doit avoir AUCUNE tension de sortie dans la tige de retour lorsqu il n y a aucun appel de chaleur ou...

Page 15: ...1 4 pouces de diam tre dans le panneau externe du v hicule come indiqu dans la Figure 1 4 Mettez l appareil en place en vous assurant que l arri re de l appareil soit aussi pr s que possible de la par...

Page 16: ...our la combustion soit pr lev dans l atmosph re ext rieure Voir Installation du syst me d admission d air et vacuation des gaz de combustion REMARQUE Lors de l installation de l appareil ne pas orient...

Reviews: