Electronic unit

OXILIFE

QUICK INSTALATION GUIDE

Electrolysis

RCA flow detector
pH probe
Redox probe

Mains connection 220V.
3.15A fuse
250 mA fuse
On-off switch
Air vent
Acid pump connection

2

3

4

5

6

7

8

9

10

11

DESCRIPTION

1

Cell

Electrolysis cell
RCA flow detector
Cell connection
Flow/gas detector

1

2

3

Optional extras

pH probe

Conductivity probe

Redox probe

Cell housing

Probe
Probe casing
Connection housing

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

5

4

With the system that utilises LOW-SALINITY ELECTROLYSIS as the flow of water passes through the titanium cell, 
oxidising agents such as OXYGEN, PEROXIDE, HYDROXYLS, OZONE, etc. are generated. This combats, oxidises 
and eliminates the organic material present in the water. The generated oxidisers turn back into H2O2 when they reach 
the pool. The salinity provided at start-up (1.5-2.5 g/l) keeps the water in perfect condition with a free chlorine residue that 
is imperceptible to the eyes and skin.

2

5

1

4

3

10

7

8

9

6

2

3

4

5

11

10

Probe
Probe casing
Connection housing

Probe
Probe casing
Connection housing

Summary of Contents for OXILIFE OXI 0

Page 1: ...1 2 3 1 2 3 1 2 3 1 2 3 5 4 With the system that utilises LOW SALINITY ELECTROLYSIS as the flow of water passes through the titanium cell oxidising agents such as OXYGEN PEROXIDE HYDROXYLS OZONE etc are generated This combats oxidises and eliminates the organic material present in the water The generated oxidisers turn back into H2O2 when they reach the pool The salinity provided at start up 1 5 2...

Page 2: ...chloric acid container optional for models with PH control not supplied with unit Acid pump Optional for models with PH control 8 Acid injector Optional for models with PH control 9 Other pool equipment pool heating heat exchanger etc 15 Electrical consumption OXILIFE synchronized with FILTRATION Ensure the electrolysis unit is synchronized with the pool filtration and stops functioning when water...

Page 3: ...RT UP 4 INITIAL ADJUSTMENTS 3 Water adjustments 1 Adjust the alkalinity between 90 and 110 ppm 2 Adjust the PH between 7 2 and 7 4 3 Adjust the chlorine between 1 and 1 5 ppm SHOULD the water be supplied from a well shock chlorinate with Tricloroisocyanuric acid 2Kg 50m3 of water Adding Salt to the Water Start up Add 1 5 to 2 5 Gramm Salt without Yod for each litre of water in your swimming pool 1...

Page 4: ...LORICACID salfumant 1 5l of acid for each 8 5l of water Once the incrustations have softened remove with a hose to complete cleaning the cell USE NO METALIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS Scratching the edges or surface of the cell will make it vulnerable to chemicals deteriorate the cell and annul the guarantee Titanium cell maintenance During the first 10 15 days your pool system will ...

Page 5: ... set point To confirm and change menu REDOX PROBE CALIBRATION Insert probe into 465mv sample wait till reading is stable CONDUCTIVITY SET POINT To modify parameters conductivity set point To confirm and change menu CONDUCTIVITY PROBE CALIBRATION Insert the probe in sample wait until reading is stable Repeat calibration or change probe Displays Conductivity control 5 Redox Free chlorine control pH ...

Page 6: ...he cell proceeding to clean it if necessary Electrolysis display shows FL Check flow detector cable Clean incrustations of flow detector at top of cell casing Check system is free of air Probe must be always submerged RUST on metallic components in pool Metallic elements lack standardized earth connection Contact an electrician to solve problem Rusted components are not stainless steel minimum 304...