background image

1

2

Thank you for selecting our product. Before starting 
installation, please read this manual thoroughly to 
ensure correct installation.

LDD-V

R

● Recessed type door damper completely concealed
    when the door is closed.

● When installed together with our HES3D concealed
    hinges, all the hardware is hidden for clean 
    appearance.

● Damper unit will pull and close the door smoothly
    and firmly right before closing (within about 10°) 
    and prevents slamming.

Product introduction

Specifications

FOR YOUR SAFE WORK AND CORRECT INSTALLATION

Maximum door width

Minimum door thickness

Door weight range

900mm (36″

)

33mm (1-5/16″

)

15-40kg (33.6-88lbs.)

● Operating temperature is 0 to 40℃.

This symbol denotes prohibited actions.

This symbol denotes what must be done.

If these cautions are not followed, it may result in injury or damage.

・This product is for indoor use only.  
 Do not use outdoors where the item is exposed to the weather.
・Do not use in a windy place as strong wind decreases the damper function. 
・Do not close the door with excessive force. It may cause damage or defect to 
 soft close mechanism.
・Make sure to follow the designated measurements and specifications as well as
 horizontal and verticals angles. Make sure that the frame is not warped, since it
 may affect the movement of the door.
・Make sure to test the screws for slack at regular intervals (one month from first 
 usage, half year and then one time every year is recommended).

C h e c k   o u r   m o v i e .

W i t h   J i g

W i t h o u t   J i g

Installation instructions

(Lapcon Door Damper)

Item No,

LDD-V-R

LDD-V-L

          Type

Right handed opening

Left handed opening

Left-hand
 opening

Right-hand
  opening

Parts List

Preparation of frame

Product

name

【The following list indicate the right hand hinge 

   for right side door hang. For left side door hang, a mirror image.】

【The following dimensions and procedures indicate the right hand
   hinge for right side door hang. For left side door hang, a mirror image.】

Parts

Quantity

1

Counter

plate cover

Binding head 

tapping screw

(nominal 3.5×20)

Binding head

tapping screw

(nominal 4×45)

Cutout template

(door side,

frame side)

Installation 
instructions
(this book)

1

1

2

2

1

1

P.1

このたびは、弊社製品をご採用いただきありがとうございます。
取付作業前に本書をよくお読みのうえ、正しく取り付けてくだ
さい。取り付け後は、本書をいつでも取り出せるよう保管して
ください。

取扱説明書

LDD-V

ラプコンドアダンパー
Lapcon Door Damper

R

● ドアを閉じると本体が外側から見えない、埋込タイプの屋
  内開き戸用ドアダンパーです。
● 弊社の3次元調節付隠し丁番 HES3D型を吊元丁番にご使
  用いただくとドアを閉めた際に、金物がすべて見えなくな
  るためドアのデザインを損ないません。
● ドア全閉間際(約10°以下)からのダンパー機能とドア引込
  み機能により、「バタン」という衝撃をやわらげ、ゆっく
  りと確実に閉まります。
● 本設計は屋内用に設計されています。屋外には取り付けな
  いでください。

本製品について

仕 様

正しく、安全に取り付けいただくために

  ドア幅

  ドア厚

ドア質量

900mm以下

33mm以上

15〜40kg

 品番

LDD-V-R

LDD-V-L

吊元仕様

右吊元用

左吊元用

● 使用推奨温度範囲は、0℃〜40℃です。

本記号はしてはいけない行為(禁止行為)であることを告げるものです。

本記号は、必ず従っていただく内容(強制、指示)であることを告げるものです。

軽傷を負うことや、物的損害が発生するおそれがある内容を示しています。

本製品は屋内用です。直接雨や雪がかかる場所でのご使用はおやめください。

強風下ではダンパー効果が低下しますので、強風下でのご使用はおやめください。

ドアを必要以上に強く閉めるなど、無理なドアの開閉はおやめください。故障の原因となります。

指定寸法、仕様を必ず守ってください。枠、ドアの反り、ねじれは故障や本来の動きに影響が出
るおそれがあります。

ねじの緩み等、異常がないか定期的に点検し、増し締めしてください(お使い始めから1ヶ月後と
6ヶ月後、その後は1年ごとが目安となります。)

注意

Product

name

Parts

Mortise jig (template)

Adjustment jig L / R 

(figure shown is for R)

※ Provides easy mortise
  cutting by router. 

※ Provides easy adjustment.

Phillips screwdriver

Flathead screwdriver

Socket wrench (14mm)

Open-end wrench 
   (8mm,14mm)

Router・Trimmer

or

枠から受座の中心までの寸法 (mm)

Counter plate 

Door damper

main unit

HES3D-120

220

222

223

221

223

224

224

221

222

225

226

227

224

HES3D-V135

218

220

221

219

222

225

228

1     2        3     4          5

HES3D-160
HES3D-190

Butt hinge

Gap between hinge side door and frame

(mm)

Hinge

HES3D-120

HES3D-160
HES3D-190

Butt hinge

219 mm + gap size

HES3D-V135

217 mm + gap size

220 mm + gap size

223 mm + gap size

Distance from frame 
to counter plate center

※ When the gap between hinge side door and 
  frame is over 5mm, refer to the chart below.

Hinge side

Distance from frame to counter plate center

Counter plate center mark

Door thickness centerline

Top gap 3-6 mm

Door stopper = Top gap + min. 9mm

(Mounting hole)

Top frame

Min. 17

Min. 20

 mm

Optional 

Accessory

 (Sold separately)

Summary of Contents for LAMP LDD-V-R

Page 1: ...or hang For left side door hang a mirror image Parts Quantity 1 Counter plate cover Binding head tapping screw nominal 3 5 20 Binding head tapping screw nominal 4 45 Cutout template door side frame side Installation instructions this book 1 1 2 2 1 1 P 1 このたびは 弊社製品をご採用いただきありがとうございます 取付作業前に本書をよくお読みのうえ 正しく取り付けてくだ さい 取り付け後は 本書をいつでも取り出せるよう保管して ください 取扱説明書 LDD V ラプコンドアダンパー Lapcon Door Damper R ドアを閉じると本体...

Page 2: ... plate Installation Install the unit after completing the adjustment of hinge and case lock Adjustment Procedure Without adjustment jig When using Adjustment Jig sold separately the procedure will change See P14 15 Do not open or close the door before adjusting the installed counter plate Operating the door without counter plate adjustment may result in malfunction causing damage to the damper doo...

Page 3: ...nt Procedure With adjustment jig When not using the adjustment Jig sold separately the procedure will change See P 12 13 Fit the jig to the damper unit 1 Close the door until the shaft and the jig contacts 2 Position of the Shaft 3 With adjustment jig Horizontal adjustment Horizontal adjustment Horizontal adjustment range 2mm Vertical adjustment Depth adjustment Loosen the horizontal adjustment sc...

Page 4: ...ake adjustments See P 10 11 Depth adjustment of Shaft is needed Depth adjustment range 2mm See P 13 without jig or P 15 with jig Depth adjustment of Shaft is needed Depth adjustment range 2mm See P 13 without jig or P 15 with jig Vertical adjustment of Shaft is needed Vertical adjustment range 2mm See P 12 without jig or P 14 with jig Horizontal adjustment of Shaft is needed Horizontal adjustment ...