SUNCOURT® RADON FAN MODEL: RDN04 & RDN04-3, RDK04 &
RDK04-3 INSTALLATION INSTRUCTIONS

READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE
READ AND SAVE THESE INSTRUCTIONS:

DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED.

CAUTION: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE
THE UNIT IS DISCONNECTED FROM THE MAIN POWER SUPPLY.

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS
OR DUST.

NEVER EXPOSE THIS FAN TO TEMPERATURES EXCEEDING 140°F (60°C).

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:

1. Do not use fan in hazardous environments where fan electrical system could provide
ignition to
combustible or flammable materials.
2. Do not use fan to exhaust explosive or corrosive gases.
3. Check voltage at the fan to insure it corresponds with product nameplate.
4. Normal operation of this device may affect the supply of fresh air needed for safe
operation of fuel burning equipment. Follow safety standards, codes, and heating
equipment manufacturer’s procedures guide lines.
5. There are no user serviceable parts located inside the fan unit. Do NOT attempt to open
(this will void manufacturer’s warranty). Return unit to the factory with original purchase
receipt for service after obtaining a Return Goods Authorization (RGA).
6. All wiring must be in accordance with local and national electrical codes. When installed
outside, power must be supplied from a GFCI (Ground Fault Circuit Interruptor).
7. Operate unit only in the manner intended. If you have questions, contact the
manufacturer.
8. Before servicing or cleaning the unit, switch power to off at service panel to prevent
power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device such as a tag to the service panel.
9. Installation work and electrical wiring must be done by a qualified person(s) in
accordance with all
applicable codes and standards, including fire-rated construction.

Radon Print

http://www.suncourt.com/Radon Print.html

1 of 7

1/2/2012 2:01 PM

Summary of Contents for RADON RDN04

Page 1: ...peration of fuel burning equipment Follow safety standards codes and heating equipment manufacturer s procedures guide lines 5 There are no user serviceable parts located inside the fan unit Do NOT attempt to open this will void manufacturer s warranty Return unit to the factory with original purchase receipt for service after obtaining a Return Goods Authorization RGA 6 All wiring must be in acco...

Page 2: ...d state speed control 1 Running watts at zero static pressure 2 Watts range at varying static pressure FAN SPECIFICATIONS Electric Motor External Rotor Ball Bearing Class B Thermally Protected Conforms To ANSI UL 705 CSA 22 2 ETL Listed Housing Material FRABS UV Protected Flame Rating UL 94V0 Housing Color White Radon Print http www suncourt com Radon Print html 2 of 7 1 2 2012 2 01 PM ...

Page 3: ...of mounting brackets provided MOUNTING Mount the fan vertically with outlet up Insure the unit is plumb and level When mounting directly on the system piping ensure that the fan does not contact any building surface to avoid vibration noise Use the flexible couplers provided to secure the fan to the piping MOUNTING BRACKET The fan may be further secured with the mounting brackets provided Radon Pr...

Page 4: ...e National Electrical Code and state and local building codes A qualified electrician should perform all electrical work Outdoor installations require the use of UL Listed watertight conduit and power supplied from a GFCI Ground Fault Circuit Interruptor ELECTRICAL CONNECTION Connect wiring with terminal block provided observing proper connections Radon Print http www suncourt com Radon Print html...

Page 5: ...in any orientation that will allow water to accumulate inside the fan housing The fans are NOT suitable for underground burial Under some circumstances a condensate bypass should be installed in the outlet ducting as shown Figure 1 This may be particularly true in cold climate installations which require long lengths of outlet ducting or when the outlet ducting is likely to produce large amounts o...

Page 6: ... more often in dusty environments Clean as necessary The unit must be disconnected from power during inspection and or cleaning SYSTEM ON INDICATOR A properly designed system should incorporate a System On Indicator to confirm system operation mode or status A manometer such as a U Tube or a vacuum alarm is recommended for this purpose SLAB COVERAGE The Suncourt Radon Fan provides coverage up to 2...

Page 7: ...o this fan There is no implied warranty of merchantability and fitness for a particular purpose Suncourt shall not be liable for any direct indirect special incidental or consequential damages arising from or relating to the fan or the performance of it Suncourt s maximum liability shall not exceed the amount of the purchase price of the fan The sole remedy under this warranty shall be the repair ...

Reviews: