background image

Summary of Contents for SD-46

Page 1: ...Dehumidifier Instruction SD 46 SD 46W with Warm Air SD 46U with UV Light SD 46UW with UV Light and Warm Air ____ 50 60 70 80 __ Please read and retain these instructions for future reference ...

Page 2: ...How it works 3 Where to position 3 Before use 4 Parts 5 Operation 6 7 Drainage 8 9 Maintenance 10 11 Trouble shooting 12 Warranty Info 13 SD 46 SD 46W SD 46U SD 46UW 46 Pints day dehumidifier 46 Pints day dehumidifier with 600W warm air 46 Pints day dehumidifier with UV light 46 Pints day dehumidifier with 600W warm air and UV light ...

Page 3: ... W 440W 4A Compressor Rotary Refrigerant R134a Working range 41 95 F Water tank capacity 12 5 pint Size WxDxH 16 14 x 8 27 x 21 46 inch N W 27 5 Ibs Above is measured under RT 86 F 30 C RH 80 The data marked with may vary for technical reasons For greater precision please refer to the rating label placed on the product ...

Page 4: ...should be positioned so that it can draw this moist air towards it from all over the home Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier close to this area and later moving it to a more central point When positioning the dehumidifier ensure that it is placed on a level surface and with a minimum of 10 cm 4 of space on either side of the unit t...

Page 5: ... plate at the back of the unit If the supply cord is damaged it must be replaced by an approved service technician or one similarly qualified Never use the plug to start or stop the unit Always use the power switch on the control panel Before moving the unit first switch off unplug and empty the water tank Do not use bug sprays or other flammable cleaners on the unit Never pour or spray water over...

Page 6: ...ir outlet 4 Water full indicator 5 Water tank 6 Handle Rear 7 Air filter air inlet 8 Power cord 9 Handle 10 Spout for continuous drainage 11 Water tank 12 Caster Assembly of the filters Washable Grille filter 7 I0 Active carbon filter Filter frar le ...

Page 7: ...n button 6 Humidity selection button 7 ON OFF button Display window I I _ 5o 6o _7 3 j 4 5 6 Humidity display _ continuous de humiditying 50 60 70 or 80 2 Ambient humidity condition _good _fair _poor _ Good Ambient room humidity is between 50 to 70 _ Fair Ambient room humidity is between 30 to 50 or 70 to 80 _ Poor Ambient room humidity is higher than 80 ...

Page 8: ...MERindicator sets timed operation from 1 to 24 hours 7 HUMIDITYlevel indicator displays the ambient room humidify level _ A 8 FANspeed indicator _ high speed _ low speed Operation 1 Plug unit into a correct main socket Please refer to the rating label at rear of the unit 2 PressON OFF button to turn on the unit The compressor will start to work in continuous mode 3 PressHUMIDITYbutton to set the d...

Page 9: ...nit When watertankbecomes full thelightturns redasa warning signal Toemptythewatertank pulloutgentlybyusing thehandleonthewatertank After emptying thetank placethewatertankbackinplace Makesureitisproperly positioned NOTE if the water tank is not positioned correctly the water full indicator will remain red and unit will beep If the water tank is full or not correctly positioned the water indicator...

Page 10: ...out is removed this will leave a hole in the housing Do not cover the opening with any type of plug if the opening is blocked water will not be able to flow out and cause possible malfunction to the unit 3 Connect the drain spout with a water tube of 12 mm inner diameter FIG 2 Note water tube is not supplied with the unit 4 Please make sure the tube is securely connected with no sharp bends or kin...

Page 11: ...filter lightly or use a vacuum cleaner to remove excess diff If the filter is particularly dirty wash with warm water and small amount of gentle detergent Allow to dry completely For active carbon filter This filter is not washable Its life span is variable and depends on the ambient conditions where the appliance is used The filter should be checked periodically about every 6 months and replaced ...

Page 12: ...l not be used for an extended period of time please Turn unit off unplug from power source and secure power cord Empty water tank and allow to dry completely Cover the unit and store in cool area away from direct sunlight ...

Page 13: ...e sure the air inlet and outlet are not obstructed THE UNIT SEEMS TO DO NOTHING Is the filter dusty or contaminated Is the air intake or outlet blocked Is the room humidity already quite low THE UNIT SEEMS TO DO LrF LE Are too many windows or doors open Is there something in the room producing lots of humidity THE UNIT IS TOO NOISY Check whether the unit is sitting on a leveled surface THE UNIT IS...

Page 14: ...placement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does not include freight charges Incidental or consequential damage caused by possible defects with this product Damage to product caused by improper power supply voltage accident fire floods or acts of ...