background image

serie

 SWUP EXT 

vertical 

120, 150, 200 L

Solar Water Tanks

INSTALLATION and OPERATION MANUAL

Versie 0.2

Summary of Contents for SWUP EXT Series

Page 1: ...serie SWUP EXT vertical 120 150 200 L Solar Water Tanks INSTALLATION and OPERATION MANUAL Versie 0 2...

Page 2: ...2 INSTALLATION and OPERATION MANUAL...

Page 3: ...ION TO INSTALLER 4 2 DESCRIPTON ON WATER TANKS 5 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK 7 4 TECHNICAL PARAMETERS 8 4 1 SWUP EXT with one coil 8 4 2 SWUP SLIM EXT with one coil 10 5 TRANSPOR...

Page 4: ...Before commissioning check the installation for leaks Do not exceed the working pressure of 10 bar Dear Customers We strongly hope that the appliance you have bought from us will contribute to creatin...

Page 5: ...e quality of the insulation of a water tanks is a key factor for its heat conservation capability and energy efficiency All water tanks SWUP EXT series have a high efficiency insulation DIN 4753 part...

Page 6: ...ed electric heater with a built in thermostat with double protection with a regulation range from 10 C to 70 C temperature of operation of the emergency protection 80 C The connection of the electric...

Page 7: ...4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a yea...

Page 8: ...8 INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS 4 1 SWUP EXT with one coil...

Page 9: ...water inlet A mm R3 4 R3 4 R3 4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 7 5 8 2 8 7 Heat exchange surface S1 m2 1 2 1 3 1 32 Coil inlet Coil outlet S1...

Page 10: ...10 INSTALLATION and OPERATION MANUAL 4 2 SWUP SLIM EXT with one coil R S1o A S1i O Z B P T U Di P Z D S1o O S1i B A R Y H...

Page 11: ...4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 6 4 8 2 8 7 Heat exchange surface S1 m2 1 1 25 1 3 Coil inlet Coil outlet S1 S1i S1o mm R3 4 R3 4 R3 4 R3 4...

Page 12: ...diately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after notic in...

Page 13: ...warranty obliga tions which might originate from external pressure of other circumstances outside NES Ltd tification number has been modified re moved or blurred or cannot be expressly attested c Dama...

Page 14: ...10 2003 and Directive 1999 44 EU concerning water heaters and their use on the territory of the EU d Any other warranty right that is not mentioned in this Warranty Certifi cate is excluded 7 RECYCLIN...

Page 15: ...15 INSTALLATION and OPERATION MANUAL...

Page 16: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Reviews: