Page 1: ...OPERATION MANUAL SK SL GKD SKH GK CL Chemical Filter Superior Performance Unbeatable Pricing Pride in Workmanship Energy Efficient Rugged Construction Please Read This Manual Carfully Before Operating ...

Page 2: ...aintenace 6 Filter Replacement 7 8 4 Troubleshooting 9 5 Appendix Type B Cartridge Nut Diagram 10 Type C Cartridge Plate Fixture Diagram 10 Type K Star Cloth Bag Diagram 11 Type P Paper Filter Diagram 11 Type U Bag and Type D Bag Cartridge Diagram 12 Part Reference Chart 13 6 Note 14 Filter Maintenance Card 15 Product Warranty 16 Table of Contents ...

Page 3: ...Recommend Stiff Pipes Inside The Tank 7 Place The Machine In An Upright Position And On A Sturdy Resting Place 8 When The Pump In Outlet Are Lower Than The Liquid Level Of The Tank Install Valves On The In Outlet Pipe To Prevent Siphoning 9 Please Make Sure The In Outlet Connection Flange Are Equal In Diameter With In Outlet Flange Please Make Sure All The Bolts And Nuts Are Adequately Tightened I...

Page 4: ...wing In Flow Monitor D During Normal Operation Please Examine If Air Is Being Sucked In Somewhere Along The Inlet Pipe 6 When The Pump Inlet And Outlet Are Lower Than The Liquid Level Of Tank Install A Chck Valves On The Inlet And Outlet Pipe To Prevent Siphoning 7 Install Check Valve on In Outlet If The Pump Is Located Under The Chemical Solution Water Tank For Easy Cleaning Maintenance Purpose E...

Page 5: ...ve 19 To Tube 8 5 Before Turning The Power On Check the In Outlet Are Connect Correctly Example Sign of Damage on Pipeline In Outlet Valve Are Open ETC 6 After Above Procedure Turn On The Pump Make Sure The Pump Is Turning At the Right Direction If Not There Won t Be Water Coming Out From The Outlet Simply Switch It the Direction From Motor Junction Box 7 Make Sure Tube Valve 10 Is Close And Tube ...

Page 6: ...hile Operating Rest Should Be Fully Closed Check Valve Function Specification on Pg 4 3 Valve E Should Be Fully Open When First Chamber Is The Only Operating Chamber Rest Should Be Closed Check Valve Function Specification on Pg 4 GKD Filter Replacement 1 Before Replacing The Filter Air Release Valve I Should Be Open and Solution Should Be Fully Drained 2 Please Read Page 15 before Removing the Ca...

Page 7: ...r Cleaning Filter Maintenance 1 Put The Cartridges And Tamis Bags Into 5 HCl Solution Soak Them For 3 5 Hours And Then Clean Them With Water Please Do Not Scrub The Cartridge and Tamis bags 2 Rinse The Filter Medium With Clean Water 3 Filter Maintenance Card Pg 24 For Routine Filter Maintenance and Request Do Not Exceed 80 of Its Pressure Range Barrel Are Design To Withstand Maximum of 3kg of Pres...

Page 8: ...r Handles 26 Clockwise To Close Counter Clockwise To Open 2 Before Opening The Cover 7 Drain The Air Out By Opening Air Release Valve 19 3 There Is One Nut 32 Inside Turn It Counterclockwise To Loosen It 4 Take The Stanchion Fastening Screw 32 Off The Filter Pick Up The Fixture Plate 33 5 The Medium Can Be Removed Easily And Then The Tamis Bag 29 Can Be Untied 6 Remove The Top Washer 35 Tamis Bag ...

Page 9: ... Using Drain Valve 27 7 Close Drain Valve 27 After Rinse Assemble The Medium In The Reversed Steps Lock The Stanchion Fastening Screw 32 And Cover 7 The Filter Should Now Be Able To Function 8 For Star Cloth Bag Diatomite Can Be Use To Increase Filtration Maintenance Of Paper Filter Type Filter Medium Refer To Figure 4 Of The Appendix Page 19 1 Turn The Cover Handles 26 Clockwise To Close Counter ...

Page 10: ...r Line Is Too Close To The Inlet Move The In Tank Air Line Secure Or Reseal Inlet PipeLine Pump Leaking Damaged Seal Damaged Pump Parts Replace Damaged Part Burnt Motor Jammed Impeller Clean Impeller and Add Strainer Single Phase Operation Install Overload Shut Off Switch Check Power Switch Pressure Gauge Does Not Move Bad Pressure Gauge Seat Seal Damagd Pressure Gauge Reseal And Reinstall Pressur...

Page 11: ...10 Type B New Construction Old Construction 5 Appendix Type C 33 12 27 13 3 22 21 20 4 29 35 6 34 31 32 23 24 25 7 2 1 10 11 9 8 15 17 19 16 26 14 18 36 5 28 22 1 ...

Page 12: ...11 Type K New Construction Old Construction Type P ...

Page 13: ...12 Type U New Construction Type D ...

Page 14: ...auge Diaphragm NBR EPT VITON 42 Filter Medium Bottom Packing NBR EPT VITON 16 Air Release Joint FRPP 43 Star Fasten Handle FRPP 17 Air Release Joint Seat with Gasket FRPP 45 Paper Center Tube PP 18 Air Release Pipe FRPP 47 Upper Disk set Cover FRPP 19 Air Release Valve FRPP 48 Lower Disk set Cover FRPP 19 1 Air Release Handle Spacer Packing NBR EPT VITON 49 Disk 20 pcs set FRPP 20 Cartridge PP 50 ...

Page 15: ...iodically Make Sure It Is Normal Clean The Medium On Schedule To Prevent Clogging When The Pump Dry Runs For A Long Time The Liquid In The Pump Will Become Very Hot And Vaporize Pressure Will Build Up Inside The Barrel And Can Potentially Explode Make Sure In Outlet Are Open 6 Please Operate The Filter Only During Working Hours Unplug The Machine When It Is Not Operating To Prevent The Filter From...

Page 16: ... Order To Maintain The Equipment Operator Must Fill The Card Truthfully 5 Have The Supervisor Manager Sign This Card Every Monday Signature Site No Date To Week Morning AM Afternoon PM Before After Appearance Signature Time Flow Pressure Kg Air Released Time Flow Pressure Kg Air Released Pressure Kg Pressure Kg Mon Tue Wed Thur Fri Sat Sun Site No Date To Week Morning AM Afternoon PM Before After ...

Page 17: ...wing Conditions The Damage Is Caused By Non Permitted Repair Improper Maintenance Or Operation Damage that Is Caused By Natural Disasters Ex Fire Earthquake Etc Normal Wear And Tear Parts And Accessories Are Not Covered In The Warranty For Any Question Or Help Please Contact Our Dealer Or Super Giant Enterprise Directly Address No 7 Lane 404 Chung Cheng South Road Yen Hang Yung Kang Tainan Taiwan ...

Page 18: ...村段 升展機械 Tel 020 82691835 82602341 3 Fax 020 62351272 上海區 江蘇省太倉市沙溪鎮岳 王區鎮北路16號 215400 塑寶環保機械 Tel 0512 53303388 53303398 Fax 0512 53303588 總公司 昇展實業股份有限公司 台灣省台南市永康區中正南路404巷7號 Tel 886 6 2534546 2541601 Fax 886 6 2534226 2420509 While placing your order Please kindly provide us the following information 1 Chemical Name Concentration Temperature Specific Gravity Viscosity 2 Capacity needed __________L mi...