Summary of Contents for SC825TQ-560LP

Page 1: ...25TQ R740UB SC825TQ R740WB SC825TQ R720LPB SC825TQ 710LP SC825TQ R720UB SC825TQ R700LP V B SC825TQ R700U V B SC825TQC 600LPB SC825TQ 600LPB SC825TQC 600WB SC835TQ 600WB SC825TQ 563UB SC825TQ 560LP V B...

Page 2: ...ction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIA...

Page 3: ...allation Refer to this chapter for detailed information on chassis rack installation You should follow the procedures given in this chapter when installing removing or reconfiguring your chassis into...

Page 4: ...25W 5 12 5 8 Installing the Air Shroud 5 13 Checking the Server s Airflow 5 14 Installation Complete 5 14 5 9 System Fans 5 15 5 10 Power Supply 5 17 Power Supply Failure 5 17 Replacing the Power Dist...

Page 5: ...SC825 Chassis Manual viii Notes...

Page 6: ...TQC R740WB 8x SAS SATA 8x SAS3 SATA 740W Redundant Platinum SC825TQC R740LPB 8x SAS SATA 8x SAS3 SATA 740W Redundant Platinum SC825TQ R740LPB 8x SAS SATA 7x LF 740W Platnum Level Redundant SC825TQ 720...

Page 7: ...supports one slim DVD ROM drive included and one slim floppy drive optional These drives allow you to quickly install or save data Other Features Other onboard features are included to promote system...

Page 8: ...he date of purchase is required be fore any warranty service will be rendered You can obtain service by calling your vendor for a Returned Merchandise Authorization RMA number When returning to the ma...

Page 9: ...SC825 Chassis Manual 1 6 Notes...

Page 10: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Page 11: ...e traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant...

Page 12: ...the protective device is rated not greater than 250 V 20 A Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit 250 V 20 A Warnung Dieses Produkt ist dar...

Page 13: ...overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Advertencia El sistema debe ser disconnected de todas las fuentes de energ...

Page 14: ...l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of hersteld door gesc...

Page 15: ...le ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta...

Page 16: ...Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plan...

Page 17: ...isposal Warning Ultimate disposal of this product should be handled according to all national laws and regulations Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplan...

Page 18: ...ot Swap Fan Warning Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnungen des L fterg...

Page 19: ...on oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen elektrischen Ger te als Pr...

Page 20: ...2 20 SC825 Chassis Manual Notes...

Page 21: ...t our website at www supermicro com This chassis supports a 2U backplane three fans and one or two power supplies SC825 models come in silver or black Backplane Each SC825 chassis comes with a 2U SAS...

Page 22: ...sually plastic which conduct the airflow directly to where it is needed Always use the air shroud included with your chassis 3 3 Where to get Replacement Components Although not frequently you may nee...

Page 23: ...antly informed of the over all status of the system as well as the activity and health of specific components Most SC825 models have two buttons on the chassis control panel a reset button and an on o...

Page 24: ...ol Panel LEDs The control panel located on the front of the SC825 chassis has six LEDs These LEDs provide you with critical information related to different parts of the system This section explains w...

Page 25: ...has a green LED When illuminated this green LED on the front of the SATA drive carrier indicates drive activity A con nection to the SATA backplane enables this LED to blink on and off when that part...

Page 26: ...Installation and General Maintnenance Installation Removing the Chassis Cover Installing Hard Drives Installing an Optional Fixed Hard Drive DVD ROM Replacement or Installation Installing the Motherbo...

Page 27: ...toward the rear of the chassis 5 Lift the cover off the chassis Warning Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allo...

Page 28: ...drives do not operate the server with the hard drives removed from the bays Figure 5 4 Removing Dummy Drive from Carrier Drive Carrier Dummy Drive 3 Install a new drive into the carrier with the prin...

Page 29: ...l the tab locks in place 5 Reconnect the data and power cables 6 Replace the chassis cover replace the server in the rack if necessary and power up the system 5 5 Installing an Optional Fixed Hard Dri...

Page 30: ...chassis place the shield into the space provided 4 Once installed the motherboard will hold the I O shield in place I O Shield Figure 5 9 I O Shield Placement Permanent and Optional Standoffs Standoff...

Page 31: ...een the motherboard backplane chassis front pan el and power supply as needed Also the fans may be temporarily removed to allow access to the backplane ports Figure 5 10 Chassis Standoffs Expansion Ca...

Page 32: ...rovided with the chas sis packaging The SC825U chassis accepts 3 full height full length slots and 3 low profile slots Installing Add on Cards in the SC825U and SC825W Chassis 1 Disconnect the power s...

Page 33: ...nue to the next chapter for rack installation instructions Figure 5 13 Air Shroud in Place in the SC825LP Chassis Three heavy duty fans provide cooling for the chassis These fans circulate air through...

Page 34: ...er is off An il luminated green light indicates that the power supply is operating Power Supply Failure SC825 chassis models have either one or two redundant power supplies In the unlikely event that...

Page 35: ...wer Distributor Redundant server chassis that are 2U or greater require a power distributor The power distributor provides failover and power supply redundancy In the unlikely event you must replace t...

Page 36: ...ressing the release tab then pulling the unit out of the chassis 5 Insert the new front port panel unit in the slot until the tab locks into place 6 Connect the data and power cables to the backplane...

Page 37: ...SC825 Chassis Manual 5 22 Notes...

Page 38: ...noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Pre cautions in the next section 6 3 Preparing for Setup T...

Page 39: ...an the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra...

Page 40: ...ner rail extension is attached to the inner rail to mount the chassis in the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chas...

Page 41: ...of the chassis to the rack Outer Rack Rails Outer rails attach to the rack and hold the chassis in place The outer rails for the SC825 chassis extend between 30 inches and 33 inches Installing the Out...

Page 42: ...SC825 Chassis Manual 6 8 Notes...

Page 43: ...o 8 pin ribbon cable for SGPIO PB free CBL 0191L Cable 50 cm 20 pin to 20 pin cable for control panel CBL 0179L Cable 70 cm SATA cable Cable 6 Two regional power cords CBL 0180L SATA various Set for 4...

Page 44: ...Type Length Description CBL 0157L Ribbon 9 8 pin to 8 pin ribbon cable for SGPIO PB free CBL 0084 Split cable 6 16 pin front control split cable CBL 0160L Cable Regional power cord CBL 0180L SATA vari...

Page 45: ...Cable Quantity 1 Part CBL 0116 Alt Name iPass or Small Four Extending Power Cables Although Supermicro chassis are designed to be efficient and cost effective some compatible motherboards have power c...

Page 46: ...SC825 Chassis Manual A 6 Notes...

Page 47: ...R PWS 561 1H20 PWS 605P 1H PWS 702A IR Rated AC Voltage 100 240V 50 60Hz 8 5 4 Amp 100 240V 60 50Hz 10 4 Amp AC Input 100 240 V 50 60 Hz 6 1 2 6 Amp 100 240 V 50 60 Hz 7 5 Amp max DC Input Voltage DC...

Page 48: ...WS 741P 1R Rated AC Voltage 100 240 V 50 60 Hz 9 3 5 Amp AC Input 100 240 V 50 60 Hz 4 9 Amp DC Input Volt age Voltage Range 36V to 75V 24A 11A Nominal Voltage 48V DC Output 3 Amp 5V standby 59 Amp 12...

Page 49: ...discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory modules or gold c...

Page 50: ...in this manual C 4 Introduction to the BPN SAS 825TQ Backplane The BPN SAS 825TQ backplane has been designed to utilize the most up to date technology available providing your system with reliable hi...

Page 51: ...BAR CODE REV 2 0 SAS825TQ 2 2 I C 1 ACT_IN JP29 9072 RESET 2 I C SIDEBAND 2 SIDEBAND 1 C 5 Front Connectors and SAS Ports Front Connectors SAS Ports 1 1 1 9 1 7 1 3 1 4 1 5 1 6 1 8 1 2 1 10 1 14 1 17...

Page 52: ...rives 3 and 4 CD ROM Floppy Pin Connectors Pin connectors designated J17 and J18 provide power to the CD ROM and floppy drives See the table on the right for pin definitions C 6 Front Connector and Pi...

Page 53: ...jumpers Closed means the jumper is on and Open means the jumper is off the pins Connector Pins Jumper Setting 3 2 1 3 2 1 Jumper Settings Jumper Jumper Settings Note JP29 Open Jumper off the pins Defa...

Page 54: ...SAS Port Connections in I2 C and SGPIO Settings Use the following chart when connecting this backplane If the SAS ports are con nected out of order it is not easy to identify drives using the LED func...

Page 55: ...SAS SATA HDD 0 SAS 4 J9 SAS SATA HDD 4 SAS 1 J2 SAS SATA HDD 1 SAS 5 J11 SAS SATA HDD 5 SAS 2 J3 SAS SATA HDD 2 SAS 6 J13 SAS SATA HDD 6 SAS 3 J4 SAS SATA HDD 3 SAS 7 J15 SAS SATA HDD 7 Rear LED Indic...

Page 56: ...revent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory mod...

Page 57: ...or 1 JP44 6 Sideband connector 2 JP52 7 Sideband connector 1 JP51 8 MG9072 chip U40 9 Upgrade header JP46 Figure D 1 Rear Connector Locations 1 1 16 32 48 BAR CODE REV 2 0 SAS825TQ 1 GND GND 12V 5V GN...

Page 58: ...3 Ground 4 12V SAS Activity LED Header Pin Definitions Pin Definition Pin Definition 1 ACT IN 0 6 ACT IN 4 2 ACT IN 1 7 ACT IN 5 3 ACT IN 2 8 ACT IN 6 4 ACT IN 3 9 ACT IN 7 5 Ground 10 Empty I2 C Con...

Page 59: ...er ID 2 JP37 1 2 Backplane ID 2 1 2 ID 0 JP38 Open Jumper off the pins I2 C Reset 2 JP40 Closed Jumper on the pins I2 C Reset_SDOUT 1 JP41 Closed Jumper on the pins I2 C Reset_SDOUT 2 JP42 1 2 I2 C Ba...

Page 60: ...er Label HDD Activity LED blue Failure LED red SAS 0 J1 ACT0 FAIL0 SAS 1 J2 ACT1 FAIL1 SAS 2 J3 ACT2 FAIL2 SAS 3 J4 ACT3 FAIL3 SAS 4 J9 ACT4 FAIL4 SAS 5 J11 ACT5 FAIL5 SAS 6 J13 ACT6 FAIL6 SAS 7 J15 A...

Page 61: ...e reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products...