background image

 

 

 

FACTORY-BUILT FIREPLACE MODEL

 

                  

 

• 

SUPREME PLUS

 

 

 

Tested and certified by Intertek 

• 

UL 127-1999

 

• 

ULC-S610-M87 R-94

 

 

 

 

 
 
 
 
 
 

OWNER’S MANUAL 

- INSTALLATION  

- OPERATION 

 
 
 
 

 

 

Keep these instructions for future use. 

 
 
 
 
 
 
 
 
 
 

Manufactured by: 

 

 

3594 Jarry East, Montreal, QC., H1Z

 2G4 

Phone: 1-877-593-4722     Fax: (514) 593-4424 

www.supremem.com 

info@supremem.com 

 
 
 
 

Summary of Contents for FACTORY-BUILT FIREPLACE

Page 1: ... certified by Intertek UL 127 1999 ULC S610 M87 R 94 OWNER S MANUAL INSTALLATION OPERATION Keep these instructions for future use Manufactured by 3594 Jarry East Montreal QC H1Z 2G4 Phone 1 877 593 4722 Fax 514 593 4424 www supremem com info supremem com ...

Page 2: ...tioned above Supreme Fireplaces Inc shall not be responsible for any labor costs 3 From the sixth through the twenty fifth year of the limited lifetime warranty SUPREME FIREPLACES INC will provide replacement parts if available at 50 of the retail price except for the parts mentioned above in exclusions SUPREME FIREPLACES INC shall not be responsible for any labor costs Transportation and other re...

Page 3: ... fireplace that will minimize the number of offsets in the chimney course Offsets will reduce the draft complicate the chimney sweeper s work and increase installation costs An installation drawing should be prepared prior to the installation work FIREPLACE INSTALLATION The fireplace can be placed directly onto or against normal combustible construction materials such as lumber plywood millboard p...

Page 4: ...evised August 2008 4 Figure 1 Make sure to seal the gap between the fireplace face and the hearth extension with a metal strip or a sand cement grout in order to prevent sparks or embers from reaching combustible materials ...

Page 5: ...e hearth extension has to be installed only as illustrated CLEARANCE TO THE FRONT OF THE FIREPLACE The minimum distance between the front of the fireplace and any combustible material is 5 feet 152 cm Do not place such materials within this minimum distance in order to reduce risk of fire ...

Page 6: ...r MacLeod HT6000 Selkirk SuperPro SPR SuperPro 2100 ALT SuperVent JSC SuperVent 2100 JM Ultra Temp CF Sentinel Simpson Dura Vent Duratech HT Duraplus HTC Metal Fab Temp Gard class A American Metal Ameritech HS HSS Figure 3 Figure 4 Figure 5 STORM COLLAR 2 MIN WALL SUPPORT FIRESTOP WALL SUPPORT FLASHING RAIN CAP ROOF FIRESTOP VENTILATED FLASHING VENTILATED FLASHING ATTIC RADIATION SHIELD RAIN CAP V...

Page 7: ...ximum of two offsets 2 elbows by offset is permitted The allowable maximum deviation is 45o in Canada and 30o in the US Secure the chimney parts according to the instructions given by chimney manufacturer A support strap a wall or a roof support must be installed above each offset in order to support the vertical length of the chimney above the offset The chimney must extend vertically through a c...

Page 8: ...abricated chimney will penetrate the masonry chimney Remove the fireplace so it will be easier to work Open a hole to the required size so that the prefabricated chimney can be inserted freely in the masonry chimney Fix with three self tapping screws the flange holder aligned with the center of the prefabricated chimney on the upper end of the elbow or tee to be connected to the liner Place and le...

Page 9: ... blower must not be installed in the fireplace casing 2 When the hot air duct passes through the chase of the fireplace the minimum distances to combustible materials must be respected The duct must be secured to prevent accidental displacement 3 The minimum distance between the blower and the fireplace is 3 feet 4 Do not use a speed control for the blower Installation To install the hot air syste...

Page 10: ...following guidelines The air duct must be insulated and have a 4 in inside diameter The length of the air duct should be as short as possible The fresh air must come from the outside and not from another room or the attic The outside register must be away from automobile exhaust fumes gas meters or other vents Avoid installing the air register at a location where it will likely be covered by snow ...

Page 11: ...te build up has occurred If a significant layer of creosote has accumulated 1 8 or more it must be removed to reduce the risk of a chimney fire TO SWEEP THE CHIMNEY 1 Open the fireplace door 2 Push the chimney sweep cap upwards and place it on the side The chimney sweep cap is located on top of the two stainless steel combustion pipes 3 Close the fireplace door 4 Sweep the chimney 5 Open the door ...

Page 12: ... maximum firewood load must not exceed 4 medium sized logs approximately 30 pounds Open the door to reload only when the wood has been reduced to charcoal otherwise there is a risk of smoke infiltration into the house This fireplace has been designed to burn with the door closed When the fireplace is functional the door should only be opened when adding more wood STARTING THE FIRE Assure that all ...

Page 13: ...combustible materials and pending final disposal The ashes should be retained in a closed container until they have cooled before disposing of them WARNINGS Even if the fireplace has not been in use for two days the ashes can still contain hot embers Since the ashtray and the container can become very hot wear gloves to avoid burns Never operate the fireplace with the ashtray door open Inspect reg...

Page 14: ...or frame Do not over tighten the nuts 9 Clean the slot embedding the door gasket and apply on the bottom of the slot a bead width between 5 32 and 3 16 of high temperature silicone 10 Install the new door gasket in the slot NOTE Use only ceramic glass of a minimum thickness of 5 mm dimensions 17 x 24 1 4 WARNINGS Do not slam the door shut if your glass doors crack or break replace the panel immedi...

Page 15: ...dary Air pipes DOS P1051 GlassC eramic5mm 17x24 25 in WP32 Door handle BL 65X300C C W C 3816 Blower T O D36T22 Thermo disk DOS P1071 Door Gasket rope 5 8 in x7 feet AS HT1044 Ashtray Gasket rope 1 2 in x3 feet DOS P1061 GlassGasket rope 3 8 in x7 feet S UPP1070 FireboxPipesS upport Panel S UPP1060 FireboxS econdary Air Panel S UPP1080 FireboxRear Panel ...