Ver 1.0 - Rev. A

The most trusted name in 

power protection.

USER MANUAL

UPS OPERATION

SU-2000Li

Summary of Contents for SU-2000Li

Page 1: ...Ver 1 0 Rev A The most trusted name in power protection USER MANUAL UPS OPERATION SU 2000Li...

Page 2: ...t a l l a t s n I 3 11 n o i t a r e p O 4 14 g n i t o o h s e l b u o r T 5 15 y r e t t a B e h t g n i c a l p e R 6 18 e c i v r e S g n i n i a t b O 7 19 s n o i t a c i f i c e p S 8 9 Configu...

Page 3: ...tion product It has been designed and manufactured to provide many years of trouble free service This symbol indicates ATTENTION This symbol indicates Risk of Electrical Shock This symbol indicates Al...

Page 4: ...grounding AC wall outlet The receptacle must be connected to the appropriate branch protection circuit breaker or fuse Connection to any other type of receptacle may result in a shock hazard and viola...

Page 5: ...are designed to provide reasonable protection against such interference in a residential installation This equip ment generates and uses radio frequency and if not installed and used properly that is...

Page 6: ...under the circumstances Examples of devices considered to be life support devices are neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes auto transfu...

Page 7: ...ED illuminates in a blinking state when the UPS is operating in the Buck mode The Buck LED will extinguish when operating in the AC normal Boost and Battery modes The Fault red LED illuminates in a st...

Page 8: ...tery s capacity drops below 80 ca pacity and then it will extinguish LED 70 70 battery capacity green yellow LED will be yellow and illuminated until the battery s capacity drops below 60 ca pacity an...

Page 9: ...s 6 The output circuit breaker will trip in the event the load exceeds the UPS s power rating 7 The Battery Backup output power receptacles The output receptacles are electrically wired into two segme...

Page 10: ...r heat ing devices water or excessive humidity or where the UPS is exposed to direct sunlight Route power cords so they cannot be walked on or damaged Operating Temperature Maximum 0 to 40 degrees C 3...

Page 11: ...he UPS NOTE The mounting brackets can also be mounted in the middle of the UPS 2 Align the mounting bracket with the mounting bracket screw holes 3 Attach the mounting bracket with the retaining screw...

Page 12: ...d OUT NOTE Connecting to the Network Phone Fax Modem modular connectors is optional The UPS works properly without this connection CONNECTING YOUR EQUIPMENT Plug the equipment into the output receptac...

Page 13: ...or unacceptable When the commercial power returns or is at an acceptable level the UPS will auto matically transfer back to the AC normal mode and start recharging the batter ies During an extended ou...

Page 14: ...default or 127VAC 240VAC Changing the Inverter On Battery output voltage to 127VAC will also change the Buck setpoint Changing the Inverter On Battery output volt age to 240VAC will also change the Br...

Page 15: ...POWER MONITORING SOFTWARE The UPS comes with a Power Monitoring Software CD See the software CD for the installation of the Power Monitoring Software USB PORT The USB protocol is HID The HID USB drive...

Page 16: ...t LED is illuminated Have a Qualified Electrician correct the service wiring The batteries may be weak or at the end of useful service life Charge the batteries for 8 hours and retest If the runtime i...

Page 17: ...present a risk of electrical shock These batteries produce sufficient current to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the batteries 1 Remove...

Page 18: ...n on the front panel to turn the UPS OFF NOTE Turn the input circuit breaker to the off position for the 208V models 3 Unplug the UPS s AC power cord from the AC wall outlet 4 Unplug the equipment fro...

Page 19: ...rify proper polarity Reconnect the battery negative black wire 19 Verify proper polarity Reconnect the battery positive red wire 20 Slide the battery module into the UPS 21 Verify proper polarity Reco...

Page 20: ...on and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authoriza tion Number RMA G If the UPS is...

Page 21: ...logy Line Interactive Sine Wave OUTPUT NON BATTERYOPERATION INPUT 1 e l g n i S e s a h P f o r e b m u N 2W G Nominal Voltage 120VAC Low Voltage Transfer Point 80V 150V resets to Utility Power at 85V...

Page 22: ...t through as a percentage of an applied ANSI C62 41 Cat A 6 kV Surge Response Time Surge Current Capability Surge Energy Rating 800 J 600 J 0 ns instantaneous normal mode 5 ns common mode 5 normal and...

Page 23: ...ience in your environment or leave factory default Enter the current date when replacing batteries Use this function to uniquely identify the UPS in your network configuration Changes output voltage f...

Page 24: ...THE SOLE AND EXCLUSIVE WARRANTY MADE BY SURGEX WITH RESPECT TO THE PRODUCT ALL IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FIT...