USER’S MANUAL

www.sven.fi

OVP-16PD

Voltage Relay 

Summary of Contents for OVP-16PD

Page 1: ...USER S MANUAL www sven fi OVP 16PD Voltage Relay ...

Page 2: ...ON Despite the exerted efforts to make this Manual more exact some discre pancies may occur The information in this Manual is given on as is terms The author and the publisher do not bear any liability to a person or an or ganization for loss or damage which has arisen from the information con tained in this Manual CONTENTS 1 PRECAUTIONS 2 PACKAGE CONTENTS 3 APPLICATION 4 FEATURES 5 TECHNICAL DESCR...

Page 3: ...nic compounds alcohol petrol solvents etc to clean the device It is prohibited to open and repair the device on your own It is prohibited to open and repair any protected equipment if it is con nected to the device socket It is prohibited to use the device with mechanical damages of its case It is prohibited to use the device in high humidity conditions Avoid ingress of water into the device Shipp...

Page 4: ...atus indication Protective shutters in the output socket Presence of protective fuse 15А 5 TECHNICAL DESCRIPTION OVP 16PD voltage relay presents a device with an electronic circuit with microprocessor control assembled in a case with a wall plug and socket OVP 16PD voltage relay provides the power supply disconnection of appliances connected to it if the power supply voltage exceeds specified value...

Page 5: ... to enter the programming mode and select programmable parameters c UP button to increase the value of a parameter being set d DOWN button to decrease the value of a parameter being set e ON forced load button exit button from the parameter setting mode f Protective shutters g Grounding contacts h Wall plug to connect the voltage relay to 230 V 50 Hz power supply network socket Fig 1 ENG User s Ma...

Page 6: ...must be in the range 10 to 35 С Before connecting equipment to the voltage relay it is necessary to set actuation values namely high voltage switching off threshold UH low voltage switching off threshold UL and turn on delay time after voltage normalization of the power supply network td see p 7 It is recom mended to set these values in accordance with operation manuals of connected equipment The tu...

Page 7: ...ymbol and the upper switching off threshold value UL in volts on the display a Set a required value using buttons UP c and DOWN d The range of possible values of the UL parameter is 150 to 215 V Start setting turn on delay value by pressing the button SET b There will be the flashing SET DS symbol and delay value td in seconds on the display Set a required value using buttons UP c and DOWN d The ran...

Page 8: ...he actual value of the mains voltage and symbols LV HV voltage below above the set limit The sub illumination of the LCD indicator in this mode is jerky The voltage relay will be in this mode as long as the voltage in the power supply network returns to the range of values from UL 7 V to UH 7 V The relay enters the turn on delay mode after its connection to the network or when it leaves the protec...

Page 9: ...upply voltage V delay time sec Default value factory setting Dimensions mm Value 140 280 50 15 3 3 125 operating mode 2500 protective mode 4500 not more than 0 3 seconds 140 280 2 150 215 1 V step 225 275 1 V step 5 999 1 sec step Ulow 198 В Uhi 253 В Delay 5 sec 53 116 80 Notes The data on the varistor fuse shown in the table are background and can not serve as a basis for claims Technical specifi...

Page 10: ... Гарантийный срок 12 мес Срок службы 2 года Производитель СВЕН ПТЕ Лимитед 176 Джу Чиат Роуд 02 02 Сингапур 427447 Произведено под контролем Свен Скандинавия Лимитед 48310 Финляндия Котка Котолахдентие 15 Сделано в Китае Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandinavia Ltd 15 Kotolah dentie Kotka Finland 48310 Made in China Regis...