Installation and usage

Installation

Leave the Sweex UPS on at all times. 
Place the Sweex UPS on a flat surface. 
In order to prevent fire or electrical shocks, do not expose the device to rain or a moist atmosphere. 
Ensure that the UPS is at lest 20 cm away from the monitor.

Charging

The UPS is fully charged at the factory itself, but during transportation, the battery may get discharged. For this reason we recommend that you
charge the Sweex UPS for at least 8 hours before use.

Connecting your hardware

Connect a computer-related product to the back of the UPS. You may connect a maximum of three devices.

English version

W W W . S W E E X . C O M

2

UPS 500 VA (BC100030) / UPS 600 VA (BC100040) / UPS 700 VA (BC100050) / UPS 800 VA (BC100060)

Advantages

Automatic voltage control 

- The voltage control increases or lowers the voltage between the mains input and the output at the optimum

level. If voltage limits are exceeded and if the AVR detects undervoltage or overvoltage, the UPS will signal this
and the voltage will again be brought to an optimal level.

If the mains voltage fails 

- A pulsating acoustic signal shall warn you when the mains voltage fails. 

Most important characteristics

Complete power protection

Automatic recharging of the batteries

Maintenance-free batteries

Remarks

Before commencing full-fledged operation of the UPS, you should first charge it for eight hours. After eight hours, the charging process of the
battery will be controlled by the electronic devices of the UPS itself. Do not connect laser printers to the UPS, since they consume a lot of power.

Description of the UPS 

LED & Indicator-
Status

LED

Acoustic

green

orange

red

none

alarm

AC mode
Battery mode
Replacement battery
Overcharging
Low battery voltage

Rear side -
1. Output(s)
2. AC input including AC fuse
3. Communication port (RS 232)
4. Telephone/modem protection (optional)

Summary of Contents for Line Interactive 500

Page 1: ...oltage between the mains input and the output at the optimum level If voltage limits are exceeded and if the AVR detects undervoltage or overvoltage the UPS will signal this and the voltage will again be brought to an optimal level If the mains voltage fails A pulsating acoustic signal shall warn you when the mains voltage fails Most important characteristics Complete power protection Automatic re...

Page 2: ...the screw with which the sliding flap is fixed See fig 7 After you have removed the sliding flap you may remove the battery from the UPS You may then carefully push out the two connecting wires see figure 8 that are connected to the battery from the battery lips fig 7 fig 8 Removing the handle Push back the handle and remove the two protective covers In order to prevent damage you should only remo...

Page 3: ...ndows XP English version W W W S W E E X C O M 6 You may download Commander Pro from Sweex Go to the Sweex website http www sweex com Select the group Security and then click UPS Select the relevant UPS you will find the Commander Pro program here To install the software use the following serial number 511C1 01220 0100 478DF2A Tips in the case of irregularities Symptom Possible cause Possible solu...

Page 4: ...ar heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit c...

Reviews: