background image

All-In-One

USER GUIDE

Summary of Contents for SD0010

Page 1: ...All In One USER GUIDE ...

Page 2: ...oblems and their solutions Configure Table of Sensor Modules Contents Standard Configuration Buttons ports Interface of Built in Software Function Connection Modes Usage of Windows Mac OSX System Usage of Android Platform Usage of iOS Platform Clean Applicable environment Storage Attentions Reset 1 2 2 3 4 5 5 6 6 9 9 9 11 13 15 15 15 15 15 15 16 17 ...

Page 3: ...human friendly Every sensor modules are set around data logger flexibly and has its own independent connection port not stereotypical Each series of SenseDisc data logger has built in accelerometer 3 Axis GPS ambient temp and barometer more diversified and high efficient SenseDisc adopts 3 5 TFT 480 320 touchscreen and a built in 1800mAh lithium battery over 6 months of standby time Sense Disc has...

Page 4: ... Hardware Standard Configuration NO Name Picture SenseDisc Data Logger 1 2 3 4 5 6 7 8 9 Screen Stylus USB Cable Power Adapter Universal Joint Aluminium rod Software CD Manual Bag 2 All In One USER GUIDE ...

Page 5: ...Buttons ports Touch Screen Power Button USB Port Threaded Hole Slot for Screen Stylus Reset Hole Sensor Modules Indicator Light of Power Supply Bracket 3 ...

Page 6: ...20 touch screen USB 2 0 Screen Port Wireless connection Size ɸ 170mm H 46mm Temperature Range 20 70 C Power Adapter 100 240V AC 5V DC 1A Software SenseDisc iLab Sensor Port 7 100 000 times s Stand alone mode Windows iOS Android Mac and etc Accelerometer 3 Axis GPS ambient temp barometer and etc Built in sensors Each series of different configuration Item Specification 4 ...

Page 7: ...ogger to form a circle type connection 7 sensor modules can be connected to the main body simultaneously Using pluggable measuring modulus and these modulus can according the requirements of experiment to be combined freely When in usage only need to insert one module into any port of the main body Indicated as follows 5 ...

Page 8: ...the USB port of main body 3rd connect the power adapter to power source Or connect the USB cable to computer Power on long press the power button until the screen lit and determines the indicator light of sensor were lit the state of sensor communication can be controlled via the built in software when connecting to a sensor the indicator light is bright Otherwise off Power off long press the powe...

Page 9: ...oth charging state sign of experimental acquisition and etc Major functional areas contains collect setting experiment and system info Function button the Home page will display our logo other pages will show the Return button click this icon SenseDisc will identify the connected sensor automatically and real time display the acquired data of sensor The opened interface will show the information o...

Page 10: ...etime can set the date time Bluetooth turn on or off the Bluetooth communication mainly used to connect with external device Bright set the brightness Storage save the experimental data and import it to external device for detailed analysis Language switch language Calibration calibrate the accuracy of screen Click this icon to enter into the setting interface Datetime Storage Bluetooth Language B...

Page 11: ... sensors info and software info of SenseDisc Click this icon or the Power button will back to the Home page Experiment System Information Click this icon system will start data acquisition after completing the acquisition experimental data will be saved automatically Click this icon or the Power button will back to the Home page 9 ...

Page 12: ...ultiple operating platforms like Windows Mac OSX Android iOS can realize the real time data acquisition via combined with PC laptop and ipad There is a briefly introduction as follows and the detailed instructions please refer to SenseDisc iLab software manual Connection Modes Wired X Wireless Connection mode Windows Mac OSX Android iOS 10 ...

Page 13: ...Connect SenseDisc to computer by USB cable Click the software icon enter into the main interface Usage of Windows Mac OSX System Click this icon choose USB click OK Wired Connection 11 ...

Page 14: ...k this icon to start data acquisition Wireless Connection Please make sure the power is sufficient before use Starting up the SenseDisc choose in slide to open Bluetooth Click the software icon click in the Home page choose Bluetooth then click OK other steps are same with the wired connection 12 ...

Page 15: ...nect the SenseDisc to the Pad datalogger Android by USB cable as follows Click the software icon enter into the Home page Usage of Android Platform Wired Connection Click choose Bluetooth then click OK 13 ...

Page 16: ...Click for example current choose current click OK create the Current Time coordinate system Click enter the experimental page Click start data acquisition 14 Choose template enter experimental platform ...

Page 17: ...Bluetooth Click click choose Bluetooth then click OK other steps are same with wired connection Before use make ensure the power is enough Starting up the SenseDisc choose in slide to open Bluetooth Open the software in iPad enter into the experimental page Choose choose Bluetooth in Setup Click Bluetooth enter the device scan page 15 ...

Page 18: ...ction will be created successfully after prompted Successful Open enter into the experimental page Click enter into the experimental platform For example current choose current click OK to create the Current Time coordinate system click to start data acquisition 16 ...

Page 19: ...strictly prohibited in the long time exposure under the sun It is strictly prohibited to immersion in water and any other liquid Do not close to the heat source Do not store it in too hot or too cold or moist environment Field operation to avoid the following weather conditions rainy snow hail heavy fog strong wind lightning and etc The SenseDisc is apply to 10 70 and 0 95 RH Noncondensation The S...

Page 20: ... installed properly if can not installed automatically try to manually install search the install position of the software open the corresponding folder find the folder which named Drive open it find Setup exe open it click install When wireless connection please check the Bluetooth setting of SenseDisc and external device are turned on Can not work Can not connect with external devices 18 ...

Page 21: ...ltage S0005 Current S0009 Temperature S0019 Light S0021 Sound Level S1024 Heart Rate S0015 Motion S0024 Heart Rate S1002 pH S1008 Humidity S0002 mV S1003 Conductivity S1005 Dissolved O S0013 Thermocoup S0014 Force S0016 Photogate S1040 UV Basic SD0010 Advance SD0020 Physics SD0030 19 2 ...

Page 22: ...Sensor Manual for Basic ...

Page 23: ...realize the measurement The voltage sensor can be used in the DC circuit and low voltage AC circuit Component Usage No Type Name Illustration 1 2 3 S0001 Voltage sensor Red crocodile clip Black crocodile clip Connect the voltage sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of voltage sensor Red black crocodile clips...

Page 24: ...ips of voltage sensor Open click choose voltage sensor click Calibration then click OK Measure the voltage at both ends of small bulb Build a simple circuit Measure the electromotive force of dry battery Voltage sensor should be parallel into the circuit when in usage Calibration before using voltage sensor Voltage sensor can not bear the voltage over 250V ...

Page 25: ...enlarging the circuit it can accurately measure the current in DC circuit or low volt age AC Component Usage No Type Name Illustration 1 2 3 S0005 Current sensor Red crocodile clip Black crocodile clip Connect the current sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of current sensor Red black crocodile clips of cur...

Page 26: ...rrent sensor Open click choose current sensor click Calibration then click OK Serial parallel circuit of resistance Measure the VA characteristic curve of small bulb Measure the electrodynamic potential and internal resistance of battery Ohm s Law Serial into the circuit when using current sensor Calibration before using current sensor Current sensor can not bear the current over 3A ...

Page 27: ...ges accordingly Normally the temperature needs no zero calibra tion and with relatively higher stability therefore the temperature sensor is rather popular in the low middle temperature measurements Component Usage No Type Name Illustration 1 2 S0009 Temperature sensor Probe Connect the temperature sensor into any port of the SensorDisc The probe of sensor insert to the socket of temperature senso...

Page 28: ...plore the endothermic effects of different colors of objects Converging lens effect We can t put any part of the sensor on the open flame or heating plate directly When measure the temperature of liquid should avoid the other partially of sensor immersed in liquid except stainless steel rod After use cleaning sensor thoroughly Don t over measured range ...

Page 29: ... signal keeping a direct proportion For the sensor the effective light spectrum is in the range of 380nm to 730nm it is an ideal intensity sensor for visible light Component Usage Connect the light sensor into any port of the SensorDisc The probe of light sensor is located at the front of sensor when use pointed the photosurface at light No Type Name Illustration 1 S0019 Light sensor ...

Page 30: ...t Explore the effects of light intensity on photosynthesis Explore the relation between light intensity and distance Measure the light intensity of environment When use always maintain the probe of sensor that facing light source Don t wear or scratch the receives of probe ...

Page 31: ...onmental sound Use the electret microphone collecting the sound signal after amplifying processing can output the value of sound intensity Component Usage Connect the Sound level sensor into any port of the SensorDisc Put the SenseDisc into the measured environment No Type Name Illustration 1 S0021 Sound level sensor ...

Page 32: ...y Measure the noise of environment Ensure that the measured sound intensity within the range If over range let the sensor away from the sound source or reduce the sound level The sensor are not waterproof if in the humid environment must do the protection measures to avoid the liquid into the sensor ...

Page 33: ... The probe adopts a transmissive ear clip when in use make the clip onto the ear lobe of the tester Component Usage Connect the Heart rate sensor into any port of SensorDisc Connect the transmissive ear clip to the sensor module Make the clip onto the ear lobe of the tester No Type Name Illustration 1 2 S1024 Heart rate sensor Probe ...

Page 34: ...vapor condensation in the detected environment when is very humid must prevent liquid invasion to the circuit part of sensor The response speed of humidity sensor will be faster in the flow air If measured environment are very dirty you should cover the ear clip by nylon cloth to avoid pollution ...

Page 35: ...quency sound wave goes around between the object and sensor in accordance with the speed of sound in air i e V it can calculate the distance between the object and the sensor i e d V T 2 Component Usage No Type Name Illustration 1 S0015 Motion sensor Connect the motion sensor into any port of the SensorDisc Pointed the ultrasonic probe at the measured object Measured object to be placed within the...

Page 36: ...armonic motion Forced vibration When use should pay attention to the blind area of measuring sensor To ensure the accuracy of measurement results the reflection surface of measured object should be facing the probe of sensor and as large as possible We should pay attention motion sensor only can sense the motion of object which nearest and produces a very strong echo ...

Page 37: ...Sensor Manual for Advance ...

Page 38: ... and the sealed vacuum reference cavity inside the sensor forms a pressure difference after the pressure difference is converted into a voltage signal its output voltage and absolute pressure to be proportional Component Usage No Type Name Illustration 1 S0024 Absolute pressure sensor Syringe Connect the Absolute pressure sensor into any port of the SensorDisc Connect the syringe with the luer por...

Page 39: ...ion rate Boyle s Law Charles Law Magdeburger Halbkugeln The effects of Catalyst have an influence on chemical reaction rate Absolute pressure sensor can only measure non corrosive gases such as air dry gas The sensor is not suitable for the measurement of flammable gas Can be used to detect the steam pressure of liquid but avoid the liquid enters into hose of probe In the pressure system the gas i...

Page 40: ...enlarging the circuit it can accurately measure the current in DC circuit or low volt age AC Component Usage No Type Name Illustration 1 2 3 S0005 Current sensor Red crocodile clip Black crocodile clip Connect the current sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of current sensor Red black crocodile clips of cur...

Page 41: ...rrent sensor Open click choose current sensor click Calibration then click OK Serial parallel circuit of resistance Measure the VA characteristic curve of small bulb Measure the electrodynamic potential and internal resistance of battery Ohm s Law Serial into the circuit when using current sensor Calibration before using current sensor Current sensor can not bear the current over 3A ...

Page 42: ... signal keeping a direct proportion For the sensor the effective light spectrum is in the range of 380nm to 730nm it is an ideal intensity sensor for visible light Component Usage Connect the light sensor into any port of the SensorDisc The probe of light sensor is located at the front of sensor when use pointed the photosurface at light No Type Name Illustration 1 S0019 Light sensor ...

Page 43: ...t Explore the effects of light intensity on photosynthesis Explore the relation between light intensity and distance Measure the light intensity of environment When use always maintain the probe of sensor that facing light source Don t wear or scratch the receives of probe ...

Page 44: ...Usage Connect the pH sensor into any port of the SensorDisc Tighten the port of electrode probe with sensor Unscrew the protective bottle of electrode probe Immerse the electrode probe of pH sensor into the solution completely Calibration Calibrate before use before Calibration prepare two kinds of buffer solution with known pH value e g pH4 00 andf pH9 18 The calibration process please refer to N...

Page 45: ...change process of electrode ion occurred the glass ball should be stored in the saturated KCl solution If the electrode was drying immersed in saturated KCl solution for 24 hours make it back to the common state Don t storeage the electrodes in distilled water or deionized water this will lead saturated solution around the electrode moving Avoid use in the extreme acid solution or extreme temperat...

Page 46: ...ges accordingly Normally the temperature needs no zero calibra tion and with relatively higher stability therefore the temperature sensor is rather popular in the low middle temperature measurements Component Usage No Type Name Illustration 1 2 S0009 Temperature sensor Probe Connect the temperature sensor into any port of the SensorDisc The probe of sensor insert to the socket of temperature senso...

Page 47: ... of acid base neutralization reaction Compare the heat conductivity of different materials The germination of seed We can t put any part of the sensor on the open flame or heating plate directly When measure the temperature of liquid should avoid the other partially of sensor immersed in liquid except stainless steel rod After use cleaning sensor thoroughly Don t over measured range ...

Page 48: ...lymer capacitance and its capacitance will vary with the environmental humidity The humidity sensor is designed to monitor the relative humidity of air Component Usage Connect the relative humidity sensor into any port of the SensorDisc Insert the probe of sensor into the socket of relative humidity sensor No Type Name Illustration 1 2 S1008 Relative humidity sensor Probe ...

Page 49: ...nd make an ecological cylinder and observe its stability Transpiration of plant If the water vapor condensation in the detected environment when is very humid must prevent liquid invasion to the circuit part of sensor The response speed of humidity sensor will be faster in the flow air If measured environment are very dirty you should cover sensor by nylon cloth to avoid pollution ...

Page 50: ...onmental sound Use the electret microphone collecting the sound signal after amplifying processing can output the value of sound intensity Component Usage Connect the Sound level sensor into any port of the SensorDisc Put the SenseDisc into the measured environment No Type Name Illustration 1 S0021 Sound level sensor ...

Page 51: ...y Measure the noise of environment Ensure that the measured sound intensity within the range If over range let the sensor away from the sound source or reduce the sound level The sensor are not waterproof if in the humid environment must do the protection measures to avoid the liquid into the sensor ...

Page 52: ...quency sound wave goes around between the object and sensor in accordance with the speed of sound in air i e V it can calculate the distance between the object and the sensor i e d V T 2 Component Usage No Type Name Illustration 1 S0015 Motion sensor Connect the motion sensor into any port of the SensorDisc Pointed the ultrasonic probe at the measured object Measured object to be placed within the...

Page 53: ...armonic motion Forced vibration When use should pay attention to the blind area of measuring sensor To ensure the accuracy of measurement results the reflection surface of measured object should be facing the probe of sensor and as large as possible We should pay attention motion sensor only can sense the motion of object which nearest and produces a very strong echo ...

Page 54: ...micro voltage sensor it can measure the mV in DC circuit or low voltage AC circuit Component Usage No Type Name Illustration 1 2 3 S0002 mV sensor Red crocodile clip Black crocodile clip Connect the mV sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of mV sensor Red black crocodile clips of mV sensor are parallel conne...

Page 55: ...he red black crocodile clips of mV sensor Open click choose mV sensor click Calibration then click OK Solar power Primary cell Faraday s law of electromagnetic induction mV sensor should be parallel into the circuit when in usage Calibration before using mV sensor mV sensor can not bear the voltage over 250V ...

Page 56: ...realize the measurement The voltage sensor can be used in the DC circuit and low voltage AC circuit Component Usage No Type Name Illustration 1 2 3 S0001 Voltage sensor Red crocodile clip Black crocodile clip Connect the voltage sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of voltage sensor Red black crocodile clips...

Page 57: ...sor click Calibration then click OK Serial parallel circuit of resistance Measure the VA characteristic curve of small bulb Ohm s Law Resistance law Charging discharging of capacitor Measurement of EMF and inner resistance of battery Voltage sensor should be parallel into the circuit when in usage Calibration before using voltage sensor Voltage sensor can not bear the voltage over 250V ...

Page 58: ...nsor into any port of the SensorDisc Tighten the port of electrode probe with sensor Unscrew the protective bottle of electrode probe Put the electrode probe of conductivity sensor into test solution No Type Name Illustration 1 2 S1003 Conductivity sensor Electrode probe Calibration Conductivity sensor has been calibration in factory the user can use it directly if has large error re calibration a...

Page 59: ...ensor conductivity sensor has been calibra tion in factory the user can use it directly if has large error re calibration again Note the Configuration method of standard solution of conductivity please reference Digital Experimental Cases of Biochemistry Click display a Calibration dialog choose conductivity sensor Click The electrode is rinsed with distilled water and wipe with an absorbent paper...

Page 60: ... the solution and apply the electric potential between the anode and the cathode to generate the electrochemical reaction Dissolved oxygen sensor also can be used for measuring oxygen content in gas Component Usage Connect the dissolved oxygen sensor into any port of the SensorDisc Tighten the port of electrode probe and sensor The probe placed in the test solution or gas environment to measure No...

Page 61: ... oxygen of different water Factors that effect plant photosynthesis Avoid contact with oil or other organic matter If there have scale on electrode immerse it in the 10 hydrochloric acid solution for 3 minutes then rinse by clean water If stained with organics immerse it in the 8 alcohol solution for 10 minutes then rinse by clean water ...

Page 62: ...he probe adopts a transmissive ear clip when in use make the clip onto the ear lobe of the tester Component Usage Connect the Heart rate sensor into any port of SensorDisc Connect the transmissive ear clip to the sensor module Make the clip onto the ear lobe of the tester No Type Name Illustration 1 2 S1024 Heart rate sensor Probe ...

Page 63: ...vapor condensation in the detected environment when is very humid must prevent liquid invasion to the circuit part of sensor The response speed of humidity sensor will be faster in the flow air If measured environment are very dirty you should cover the ear clip by nylon cloth to avoid pollution ...

Page 64: ...al and chemical experiment in middle school it can measure the temperature of flame directly there is no need to worry about whether the cable could be damaged by high temperature Component Usage Connect the thermocouple sensor into any port of the SensorDisc Connect the probe to the socket of thermocouple sensor No Type Name Illustration 1 2 S0013 Thermocouple sensor Probe ...

Page 65: ...hot water cooling Explore the temperature changes when a solid melts Explore different parts of the alcohol lamp flame temperature When in use do not exceed the sensor s measuring range Probe can be immersed in corrosive liquids or object for measurement but remember to wipe the probe after testing and keep it dry for storage ...

Page 66: ... can measure the force value accurately Component Usage Connect the Force sensor with universal port then Connect the Universal port into any port of the SensorDisc The Force sensor can be measured the tension and pressure simultaneously pushing the metal hook display the positive value pulling the metal hook display the negative value No Type Name Illustration 1 2 3 S3000 S0014 Universal port For...

Page 67: ...sor and the sensor to be vertical in the measurement process otherwise it will infect the results of the measurement Don t over measured range otherwise irreparable damage to Force sensor Hook of force sensor not tighten too much otherwise it will infect the results of the measurement Firstly tighten and fixed the hook of force sensor Measuring what state forces that placed the force sensor at wha...

Page 68: ...Sensor Manual for Physics ...

Page 69: ... and the sealed vacuum reference cavity inside the sensor forms a pressure difference after the pressure difference is converted into a voltage signal its output voltage and absolute pressure to be proportional Component Usage No Type Name Illustration 1 S0024 Absolute pressure sensor Syringe Connect the Absolute pressure sensor into any port of the SensorDisc Connect the syringe with the luer por...

Page 70: ... Case Boyle s Law Boyle s Law Charles Law Magdeburger Halbkugeln Absolute pressure sensor can only measure non corrosive gases such as air dry gas The sensor is not suitable for the measurement of flammable gas Can be used to detect the steam pressure of liquid but avoid the liquid enters into hose of probe In the pressure system the gas in the container has a certain degree of overflow therefore ...

Page 71: ...realize the measurement The voltage sensor can be used in the DC circuit and low voltage AC circuit Component Usage No Type Name Illustration 1 2 3 S0001 Voltage sensor Red crocodile clip Black crocodile clip Connect the voltage sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of voltage sensor Red black crocodile clips...

Page 72: ...ltage sensor Open click choose voltage sensor click Calibration then click OK Serial parallel circuit of resistance Measure the VA characteristic curve of small bulb LC oscillation Ohm s Law Voltage sensor should be parallel into the circuit when in usage Calibration before using voltage sensor Voltage sensor can not bear the voltage over 250V ...

Page 73: ... signal keeping a direct proportion For the sensor the effective light spectrum is in the range of 380nm to 730nm it is an ideal intensity sensor for visible light Component Usage Connect the light sensor into any port of the SensorDisc The probe of light sensor is located at the front of sensor when use pointed the photosurface at light No Type Name Illustration 1 S0019 Light sensor ...

Page 74: ...tween illumination intensity and distance Explore the relation between light intensity and distance Measure the light intensity of environment When use always maintain the probe of sensor that facing light source Don t wear or scratch the receives of probe ...

Page 75: ...es accordingly Normally the temperature needs no zero calibra tion and with relatively higher stability therefore the temperature sensor is rather popular in the low middle temperature measurements Component Usage No Type Name Illustration 1 2 S0009 Temperature sensor Probe Connect the temperature sensor into any port of the SensorDisc Insert the probe of sensor into the socket of temperature sens...

Page 76: ...iquid and air pressure Compare the heat conductivity of different material We can t put any part of the sensor on the open flame or heating plate directly When measure the temperature of liquid should avoid the other partially of sensor immersed in liquid except stainless steel rod After use cleaning sensor thoroughly Don t over measured range ...

Page 77: ...enlarging the circuit it can accurately measure the current in DC circuit or low volt age AC Component Usage No Type Name Illustration 1 2 3 S0005 Current sensor Red crocodile clip Black crocodile clip Connect the current sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of current sensor Red black crocodile clips of cur...

Page 78: ...rrent sensor Open click choose current sensor click Calibration then click OK Serial parallel circuit of resistance Measure the VA characteristic curve of small bulb Measure the electrodynamic potential and internal resistance of battery Ohm s Law Serial into the circuit when using current sensor Calibration before using current sensor Current sensor can not bear the current over 3A ...

Page 79: ...onmental sound Use the electret microphone collecting the sound signal after amplifying processing can output the value of sound intensity Component Usage Connect the Sound level sensor into any port of the SensorDisc Put the SenseDisc into the measured environment No Type Name Illustration 1 S0021 Sound level sensor ...

Page 80: ...y Measure the noise of environment Ensure that the measured sound intensity within the range If over range let the sensor away from the sound source or reduce the sound level The sensor are not waterproof if in the humid environment must do the protection measures to avoid the liquid into the sensor ...

Page 81: ...quency sound wave goes around between the object and sensor in accordance with the speed of sound in air i e V it can calculate the distance between the object and the sensor i e d V T 2 Component Usage No Type Name Illustration 1 S0015 Motion sensor Connect the motion sensor into any port of the SensorDisc Pointed the ultrasonic probe at the measured object Measured object to be placed within the...

Page 82: ... of the object The movement of bubbles Measure the velocity via sensor When use should pay attention to the blind area of measuring sensor To ensure the accuracy of measurement results the reflection surface of measured object should be facing the probe of sensor and as large as possible We should pay attention motion sensor only can sense the motion of object which nearest and produces a very str...

Page 83: ...micro voltage sensor it can measure the mV in DC circuit or low voltage AC circuit Component Usage No Type Name Illustration 1 2 3 S0002 mV sensor Red crocodile clip Black crocodile clip Connect the mV sensor into any port of the SensorDisc Wires of red black crocodile clip should be inserted into the positive and negative port of mV sensor Red black crocodile clips of mV sensor are parallel conne...

Page 84: ...he red black crocodile clips of current sensor Open click choose mV sensor click Calibration then click OK Faraday s law of electromagnetic induction Solar power Primary cell mV sensor should be parallel into the circuit when in usage Calibration before using mV sensor mV sensor can not bear the voltage over 250V ...

Page 85: ... can measure the force value accurately Component Usage Connect the Force sensor with universal port then Connect the Universal port into any port of the SensorDisc The Force sensor can be measured the tension and pressure simultaneously pushing the metal hook display the positive value pulling the metal hook display the negative value No Type Name Illustration 1 2 3 S3000 S0014 Universal port For...

Page 86: ...and the sensor to be vertical in the measurement process otherwise it will infect the results of the measurement Don t over measured range otherwise irreparable damage to Force sensor Hook of force sensor not tighten too much otherwise it will infect the results of the measurement Firstly tighten and fixed the hook of force sensor Measuring what state forces that placed the force sensor at what st...

Page 87: ...l be in high voltage off state Component Usage Connect the phtotgate sensor with universal port then Connect the Universal port into any port of the SensorDisc When use phtotgate sensor according to the experimental type and accessories we can set it as follows No Type Name Illustration 1 2 3 S3000 S0016 Universal port Phtotgate Trilobular screw open click choose experimental type type of light ba...

Page 88: ... Calibrate the phtotgate sensor before usage Installation of phtotgate sensor is varied should according to the specific experimental flexibly assembled pay attention that accurate positioning and firm connection in the assembly process The phtotgate is very sensitive to the high intensity infrare and heat of surrounding environment should avoid bright light Because the glare will produce an error...

Page 89: ...Sensor Manual for Biochemistry ...

Page 90: ...the front luer whereas the luer and the sealed vacuum reference cavity inside the sensor forms a pressure difference after the pressure difference is converted into a voltage signal its output voltage and absolute pressure to be proportional Component Usage No Type Name Illustration 1 S0024 Absolute pressure sensor Syringe Connect the Absolute pressure sensor into any port of the SensorDisc ...

Page 91: ...action rate Boyle s Law Charles Law Magdeburger Halbkugeln The effects of Catalyst have an influence on chemical reaction rate Absolute pressure sensor can only measure non corrosive gases such as air dry gas The sensor is not suitable for the measurement of flammable gas Can be used to detect the steam pressure of liquid but avoid the liquid enters into hose of probe In the pressure system the ga...

Page 92: ...sensor into any port of the SensorDisc Tighten the port of electrode probe and sensor Unscrew the protective bottle of electrode probe Put the electrode probe of conductivity sensor into test solution No Type Name Illustration 1 2 S1003 Conductivity sensor Electrode probe Calibration Conductivity sensor has been calibration in factory the user can use it directly if has large error re calibration ...

Page 93: ...ensor conductivity sensor has been calibra tion in factory the user can use it directly if has large error re calibration again Note the Configuration method of standard solution of conductivity please reference Digital Experimental Cases of Biochemistry Click display a Calibration dialog choose conductivity sensor Click The electrode is rinsed with distilled water and wipe with an absorbent paper...

Page 94: ... signal keeping a direct proportion For the sensor the effective light spectrum is in the range of 380nm to 730nm it is an ideal intensity sensor for visible light Component Usage Connect the light sensor into any port of the SensorDisc The probe of light sensor is located at the front of sensor when use pointed the photosurface at light No Type Name Illustration 1 S0019 Light sensor ...

Page 95: ...light intensity of environment Explore the effects of light intensity on photosynthesis Measure the light intensity of environment When use always maintain the probe of sensor that facing light source Don t wear or scratch the receives of probe ...

Page 96: ...al and chemical experiment in middle school it can measure the temperature of flame directly there is no need to worry about whether the cable could be damaged by high temperature Component Usage Connect the thermocouple sensor into any port of the SensorDisc Connect the probe to the socket of thermocouple sensor No Type Name Illustration 1 2 S0013 Thermocouple sensor Probe ...

Page 97: ... cooling Explore different parts of the alcohol lamp flame temperature When in use do not exceed the sensor s measuring range Probe can be immersed in corrosive liquids or object for measurement but remember to wipe the probe after testing and keep it dry for storage ...

Page 98: ...he probe adopts a transmissive ear clip when in use make the clip onto the ear lobe of the tester Component Usage Connect the Heart rate sensor into any port of SensorDisc Connect the transmissive ear clip to the sensor module Make the clip onto the ear lobe of the tester No Type Name Illustration 1 2 S1024 Heart rate sensor Probe ...

Page 99: ...vapor condensation in the detected environment when is very humid must prevent liquid invasion to the circuit part of sensor The response speed of humidity sensor will be faster in the flow air If measured environment are very dirty you should cover the ear clip by nylon cloth to avoid pollution ...

Page 100: ...olymer capacitance and its capacitance will vary with the environmental humidity The humidity sensor is designed to monitor the relative humidity of air Component Usage Connect the relative humidity sensor into any port of the SensorDisc The probe of sensor insert to the socket of relative humidity sensor No Type Name Illustration 1 2 S1008 Relative humidity sensor Probe ...

Page 101: ...al cylinder and observe its stability Transpiration of plant If the water vapor condensation in the detected environment when is very humid must prevent liquid invasion to the circuit part of sensor The response speed of humidity sensor will be faster in the flow air If measured environment are very dirty you should cover sensor by nylon cloth to avoid pollution ...

Page 102: ... Usage Connect the pH sensor into any port of the SensorDisc Tighten the port of electrode probe and sensor Unscrew the protective bottle of electrode probe The electrode probe of pH sensor immersed in the solution completely Calibration Calibrate before use before Calibration prepare two kinds of buffer solution with known pH value e g pH4 00 andf pH9 18 The calibration process please refer to No...

Page 103: ...rodes by measured solution In order to keep the exchange process of electrode ion occurred the glass ball should be stored in the saturated KCl solution If the electrode was drying immersed in saturated KCl solution for 24 hours make it back to the common state Don t storeage the electrodes in distilled water or deionized water this will lead saturated solution around the electrode moving Avoid us...

Page 104: ...accordingly Normally the temperature needs no zero calibra tion and with relatively higher stability therefore the temperature sensor is rather popular in the low middle temperature measurements Component Usage No Type Name Illustration 1 2 S0009 Temperature sensor Probe Connect the temperature sensor into any port of the SensorDisc Insert the probe of sensor into the socket of relative humidity s...

Page 105: ... of acid base neutralization reaction Compare the heat conductivity of different materials The germination of seed We can t put any part of the sensor on the open flame or heating plate directly When measure the temperature of liquid should avoid the other partially of sensor immersed in liquid except stainless steel rod After use cleaning sensor thoroughly Don t over measured range ...

Page 106: ... the solution and apply the electric potential between the anode and the cathode to generate the electrochemical reaction Dissolved oxygen sensor also can be used for measuring oxygen content in gas Component Usage Connect the dissolved oxygen sensor into any port of the SensorDisc Tighten the port of electrode probe and sensor The probe placed in the test solution or gas environment to measure No...

Page 107: ... oxygen of different water Factors that effect plant photosynthesis Avoid contact with oil or other organic matter If there have scale on electrode immerse it in the 10 hydrochloric acid solution for 3 minutes then rinse by clean water If stained with organics immerse it in the 8 alcohol solution for 10 minutes then rinse by clean water ...

Page 108: ...Sensor Manual for Environment ...

Page 109: ...ng 100nm to 400nm in the electromagnet ic spectrum belongs to the ultraviolet wavelength range UV sensor can transform the received uv intensity into a proportional output voltage signal Component Usage Connect the UV sensor into any port of the SensorDisc Placed the sensor on the test environment No Type Name Illustration 1 S1040 UV sensor ...

Page 110: ...ctric effect Impact of different intensities of ultraviolet ray on biological survival rate In experiment the UV sensor was placed under ultraviolet irradiation the human eyes can not touch ultraviolet light directly According to different experimental conditions adjusting the acquisition time and frequency in the software ...

Page 111: ... Usage Connect the pH sensor into any port of the SensorDisc Tighten the port of electrode probe and sensor Unscrew the protective bottle of electrode probe The electrode probe of pH sensor immersed in the solution completely Calibration Calibrate before use before Calibration prepare two kinds of buffer solution with known pH value e g pH4 00 andf pH9 18 The calibration process please refer to No...

Page 112: ...rodes by measured solution In order to keep the exchange process of electrode ion occurred the glass ball should be stored in the saturated KCl solution If the electrode was drying immersed in saturated KCl solution for 24 hours make it back to the common state Don t storeage the electrodes in distilled water or deionized water this will lead saturated solution around the electrode moving Avoid us...

Page 113: ...onmental sound Use the electret microphone collecting the sound signal after amplifying processing can output the value of sound intensity Component Usage Connect the Sound level sensor into any port of the SensorDisc Put the SenseDisc into the measured environment No Type Name Illustration 1 S0021 Sound level sensor ...

Page 114: ...y Measure the noise of environment Ensure that the measured sound intensity within the range If over range let the sensor away from the sound source or reduce the sound level The sensor are not waterproof if in the humid environment must do the protection measures to avoid the liquid into the sensor ...

Page 115: ... signal keeping a direct proportion For the sensor the effective light spectrum is in the range of 380nm to 730nm it is an ideal intensity sensor for visible light Component Usage Connect the light sensor into any port of the SensorDisc The probe of light sensor is located at the front of sensor when use pointed the photosurface at light No Type Name Illustration 1 S0019 Light sensor ...

Page 116: ...t Explore the effects of light intensity on photosynthesis Explore the relation between light intensity and distance Measure the light intensity of environment When use always maintain the probe of sensor that facing light source Don t wear or scratch the receives of probe ...

Page 117: ...lymer capacitance and its capacitance will vary with the environmental humidity The humidity sensor is designed to monitor the relative humidity of air Component Usage Connect the relative humidity sensor into any port of the SensorDisc Insert the probe of sensor into the socket of relative humidity sensor No Type Name Illustration 1 2 S1008 Relative humidity sensor Probe ...

Page 118: ...nder and observe its stability Transpiration of plant If the water vapor condensation in the detected environment when is very humid must prevent liquid invasion to the circuit part of sensor The response speed of humidity sensor will be faster in the flow air If measured environment are very dirty you should cover sensor by nylon cloth to avoid pollution ...

Page 119: ...es accordingly Normally the temperature needs no zero calibra tion and with relatively higher stability therefore the temperature sensor is rather popular in the low middle temperature measurements Component Usage No Type Name Illustration 1 2 S0009 Temperature sensor Probe Connect the temperature sensor into any port of the SensorDisc Insert the probe of sensor into the socket of temperature sens...

Page 120: ...e the heat conductivity of different materials The convex lens convergence effect We can t put any part of the sensor on the open flame or heating plate directly When measure the temperature of liquid should avoid the other partially of sensor immersed in liquid except stainless steel rod After use cleaning sensor thoroughly Don t over measured range ...

Page 121: ... the solution and apply the electric potential between the anode and the cathode to generate the electrochemical reaction Dissolved oxygen sensor also can be used for measuring oxygen content in gas Component Usage Connect the dissolved oxygen sensor into any port of the SensorDisc Tighten the port of electrode probe and sensor The probe placed in the test solution or gas environment to measure No...

Page 122: ... oxygen of different water Factors that effect plant photosynthesis Avoid contact with oil or other organic matter If there have scale on electrode immerse it in the 10 hydrochloric acid solution for 3 minutes then rinse by clean water If stained with organics immerse it in the 8 alcohol solution for 10 minutes then rinse by clean water ...

Page 123: ...ts are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this eq...