Page 1: ...LS 2106 Product Reference Guide ...

Page 2: ...2 70 32821 01 Revision D September 2000 Symbol Technologies Inc One Symbol Plaza Holtsville N Y 11742 1300 LS 2106 Product Reference Guide ...

Page 3: ...LS 2106 Product Reference Guide 70 32821 01 Revision D September 2000 ...

Page 4: ...on or use of any product circuit or application described herein No license is granted either expressly or by implication estoppel or otherwise under any patent right or patent covering or relating to any combination system apparatus machine material method or process in which Symbol products might be used An implied license only exists for equipment circuits and subsystems contained in Symbol pro...

Page 5: ...the LS 2106 1 3 Installing the Cable 1 3 Switching Cables 1 3 Connecting to a Host 1 4 Chapter 2 Scanning with the LS 2106 Introduction 2 1 Scanning with the LS 2106 2 1 LS 2106 Decode Zone 2 4 Chapter 3 Maintenance and Specifications Introduction 3 1 Maintenance 3 1 Troubleshooting 3 1 Accessories 3 2 Standard Accessories 3 2 Cables 3 2 Optional Accessories 3 3 Technical Specifications 3 3 ...

Page 6: ...Supplementals 4 18 Transmit UPC A UPC E Check Digit 4 19 UPC A Preamble 4 20 UPC E Preamble 4 21 Convert UPC E to UPC A 4 22 EAN Zero Extend 4 23 EAN Zero Extend Code Type 4 24 Enable Disable Code 128 4 25 Enable Disable UCC EAN 128 4 26 Enable Disable Code 39 4 27 Code 39 Check Digit Verification 4 28 Transmit Code 39 Check Digit 4 29 Do Not Transmit Code 39 Check Digit 4 29 Enable Disable Code 3...

Page 7: ...t MSI Plessey Check Digit 4 45 Do Not Transmit MSI Plessey Check Digit 4 45 MSI Plessey Check Digit Algorithm 4 46 Transmit Code ID Character 4 47 Transmit Code ID Character 4 48 Prefix Suffix Values 4 49 Scan Data Transmission Format 4 50 Host Interfaces 4 52 National Keyboard Types 4 53 Fast Transmit 4 55 Intercharacter Delay 4 56 Numeric Bar Codes 4 57 Cancel 4 59 Keyboard Maps 4 60 Appendix A ...

Page 8: ...vi LS 2106 Product Reference Guide ...

Page 9: ...ribe step by step procedures appear as numbered lists Related Publications LS 2100 Series Quick Reference Guide p n 70 32817 xx LS 2100 Product Reference Guide p n 70 32818 xx LS 2104 Product Reference Guide p n 70 32820 xx Service Information If you have a problem with your equipment contact the Symbol Support Centers Before calling have the model number serial number and several of your bar code...

Page 10: ...nce contact or call the Symbol Support Center in United States Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 1 800 653 5350 Canada Symbol Technologies Canada Inc 2540 Matheson Boulevard East Mississauga Ontario Canada L4W 4Z2 905 629 7226 United Kingdom Symbol Technologies Symbol Place Winnersh Triangle Berkshire RG41 5TP United Kingdom 0800 328 2424 Inside UK 44 208 945 ...

Page 11: ... Germany 49 6074 49020 Outside Germany Italy Symbol Technologies Italia S R L Via Cristoforo Columbo 49 20090 Trezzano S N Navigilo Milano Italy 2 484441 Inside Italy 39 02 484441 Outside Italy Latin America Sales Support 7900 Glades Road Suite 340 Boca Raton Florida 33434 USA 1 800 347 0178 Inside United States 1 561 483 1275 Outside United States Mexico Symbol Technologies Mexico Ltd Torre Picas...

Page 12: ...d in accordance with any operating or handling instructions supplied by Symbol iii which has been subjected to unusual physical or electrical stress misuse abuse power shortage negligence or accident or iv which has been used other than in accordance with the product operating and handling instructions Preventive maintenance is the responsibility of customer and is not covered under this warranty ...

Page 13: ... the exchange Customer accepts full responsibility for its software and data including the appropriate backup thereof Repair or replacement of a product during warranty will not extend the original warranty term Symbol s Customer Service organization offers an array of service plans such as on site depot or phone support that can be implemented to meet customer s special operational requirements a...

Page 14: ...xii LS 2106 Product Reference Guide ...

Page 15: ...gine mylar scan element and the Visible Laser Diode VLD This state of the art technology gives the scanner a wider decode zone greater depth of field and a visible scan beam This model reads color bar codes and symbols printed on all substrates See the LS 2106 Decode Zone on page 2 4 Figure 1 1 LS 2106 Scanner Here s what each member of the LS 2100 family offers you LS 2100 The aggressiveness of t...

Page 16: ...e scanner contains on board discrete keyboard wedge communications for connecting to asynchronous terminals and host systems It can also accommodate any of the Synapse Smart Cables which allows you to connect to a wide variety of host systems Some installations require one cable others require additional adapters between the keyboard the PC and the y cable All of the LS 2100 series scan automatica...

Page 17: ...low Figure 1 2 Installing the Cable Switching Cables Different cables are required for different hosts To change the scanner cable 1 Press the tab on the cable with a small screwdriver 2 Pull the cable out of the receptacle on the bottom of the scanner 3 Insert a new cable in the receptacle Press the cable into the receptacle until you hear a click ...

Page 18: ... controller user documentation for full details Figure 1 3 Connecting to a Host IBM via Synapse Adapter Cable OCIA via Synapse Keyboard Wedge via Synapse Keyboard Wedge Host LS 2106 Host LS 2106 Synapse Smart Cable Power Supply As Required LS 2106 Synapse Adapter Cable Synapse Smart Cable IBM 4683 84 93 94 C Cash Register Host LS 2106 Synapse Smart Cable Power Supply As Required Synapse Adapter Ca...

Page 19: ... to Chapter 4 Parameter Menus for instructions on programming your scanner If you need assistance contact your local supplier or Symbol Techologies 1 Before you use the scanner make sure all cable connections are secure 2 Make sure the bar code is in the correct scanning range Aim and press the trigger the scan beam lights and an orange light illuminates at the rear of the scanner The scanner has ...

Page 20: ...light reflecting directly back into the scanner from the bar code is known as specular reflection This strong light can blind the scanner and make decoding difficult The area where specular reflection occurs is known as a dead zone You can tilt the scanner up to 55 forward or back and achieve a successful decode Simple practice quickly shows what tolerances to work within ...

Page 21: ... that are close together Right Wrong What Does The Beep Mean When you hear 1 beep short high tone it means data has been decoded successfully If any other beeps are heard contact the technical person in charge of scanning When the symbol has been successfully decoded you will hear a short high tone beep and the green decode LED will light For more specific information on the meanings of the variou...

Page 22: ...2 4 LS 2106 Product Reference Guide LS 2106 Decode Zone ...

Page 23: ...w any abrasive material to touch the window Remove any dirt particles with a damp cloth Wipe the window using a tissue moistened with ammonia water Do not spray water or other cleaning liquids directly into the window Do not remove the nose of the scanner Troubleshooting If after following the operating instructions the scanner does not work Check the system power Make sure the controller is progr...

Page 24: ... viii for the telephone number Accessories Standard Accessories Cables Description Part Number LS 2100 Series Quick Reference Guide 70 32817 xx LS 2106 Product Reference Guide 70 32821 xx Shipping Box 50 01400 184 Description Part Number PS 2 Y Scanner Cable 25 31828 01 PS 2 to AT XT Adapter Connectors KT 32903 01 Set IBM SureOne PS2 Cable 25 17359 01 Synapse Adapter Cable 25 31617 01 110V Power S...

Page 25: ... Codabar Interleaved 2 of 5 Discrete 2 of 5 Code 93 MSI Plessey Decode Depth of Field Maximum typical working distance is 11 0 in 100 UPC EAN minimum element width resolution is 5 5 mils Scan Repetition Rate Approximately 36 scans sec bidirectional Skew Tolerance 55 min from normal Pitch Tolerance 50 from normal Yaw 35 at 6 in on 100 UPC EAN Print Contrast Minimum 20 minimum reflectance differenti...

Page 26: ...3 4 LS 2106 Product Reference Guide Straight Cable Length 6 ft 183 cm Weight without cable 5 5 oz 170 gm Dimensions Height 6 7 in 167 mm Width 2 8 in 70 mm Depth 3 4 in 85 mm Item Description ...

Page 27: ...l return current 4 Terminal Clock Bidirectional clock signal used to communicate between the host terminal and the scanner or keyboard 6 Synapse Data Data line for Synapse communication 7 Synapse Clock Clock line for Synapse communication 8 Terminal Data Bidirectional data signal used to communicate between the host terminal and the scanner or keyboard 9 Keyboard Data Clamp Active low output data ...

Page 28: ...3 6 LS 2106 Product Reference Guide Figure 3 1 10 pin Connector PIN 1 PIN 10 ...

Page 29: ...ect menu sequence performed Lo hi tone Input error incorrect bar code or Cancel scanned wrong entry incorrect bar code programming sequence remain in program mode Hi lo tone Keyboard parameter selected Enter value using bar code keypad Hi lo hi lo tone Successful program exit with change in the parameter setting Code 39 Buffering Hi lo tone New Code 39 data was entered into the buffer 3 Beeps long...

Page 30: ...3 8 LS 2106 Product Reference Guide ...

Page 31: ...g the appropriate bar codes included in this manual These new values replace the standard default values in memory The default parameter values can be recalled by scanning the SET ALL DEFAULTS bar code on page 4 7 The scanner automatically identifies the host type on power up It makes this determination provided the host is powered up before the scanner is attached to it The following table lists ...

Page 32: ...ter Good Decode Enable 4 11 Transmit No Read Message Disable 4 12 Decode Redundancy Level 0 4 13 Autodiscriminate Response Time 1 second 4 14 UPC EAN UPC A Enable 4 15 UPC E Enable 4 15 EAN 8 Enable 4 16 EAN 13 Enable 4 16 Bookland EAN Disable 4 17 Decode UPC EAN Supplementals Ignore 4 18 Transmit UPC A Check Digit Enable 4 19 Transmit UPC E Check Digit Enable 4 19 UPC A Preamble System Character ...

Page 33: ... 4 24 Code 128 Code 128 Enable 4 25 UCC EAN 128 Enable 4 26 Code 39 Code 39 Enable 4 27 Code 39 Check Digit Verification Disable 4 28 Transmit Code 39 Check Digit Disable 4 29 Code 39 Full ASCII Conversion Disable 4 30 Buffer Code 39 Disable 4 31 Table 4 1 Default Parameters Continued Parameter Default Page Number ...

Page 34: ...e 4 35 Set Length s for I 2 of 5 14 4 36 Convert I 2 of 5 to EAN 13 Disable 4 37 Discrete 2 of 5 Discrete 2 of 5 Disable 4 38 Set Length s for D 2 of 5 12 4 39 Codabar Codabar Disable 4 40 CLSI Editing Disable 4 41 NOTIS Editing Disable 4 42 Table 4 1 Default Parameters Continued Parameter Default Page Number ...

Page 35: ...MSI Plessey Check Digit Disable 4 45 MSI Plessey Check Digit Algorithm Mod 10 Mod 10 4 46 Data Options Transmit Code ID Character None 4 48 Prefix Suffix Values 7013 CR LF for serial 4 49 Scan Data Transmission Format Data as is 4 51 Table 4 1 Default Parameters Continued Parameter Default Page Number ...

Page 36: ...Reference Guide Keyboard Wedge Host Type IBM PC AT 4 52 National Keyboard Type North American 4 53 Fast Transmit Enabled 4 55 Intercharacter Delay 0 4 56 Table 4 1 Default Parameters Continued Parameter Default Page Number ...

Page 37: ...4 7 Parameter Menus Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 4 1 beginning on page 4 2 SET ALL DEFAULTS ...

Page 38: ...4 8 LS 2106 Product Reference Guide Beeper Volume To select a beeper volume scan the LOW VOLUME or HIGH VOLUME bar code LOW VOLUME HIGH VOLUME ...

Page 39: ...To set a Laser On Time scan the bar code below Next scan two numeric bar codes beginning on page 4 57 that correspond to the desired time on Single digit numbers must have a leading zero For example to set a Time On of 5 seconds scan the bar code below then scan the 0 and 5 bar codes If you make an error or wish to change your selection scan the CANCEL bar code on page 4 59 LASER ON TIME ...

Page 40: ...hether or not power remains on after a decode attempt When in low power mode the scanner enters into a low power consumption mode to preserve battery life after each decode attempt When in continuous power mode power remains on after each decode attempt CONTINUOUS ON LOW POWER ...

Page 41: ... unit to beep after a good decode BEEP AFTER GOOD DECODE Do Not Beep After Good Decode Scan this symbol if you do not want the unit to beep after a good decode The beeper still operates during parameter menu scanning and indicates error conditions DO NOT BEEP AFTER GOOD DECODE ...

Page 42: ... enabled if a symbol does not decode NR is transmitted Any prefixes or suffixes which have been enabled are appended around this message ENABLE NO READ Do Not Transmit No Read Message When disabled if a symbol does not read nothing is sent to the host DISABLE NO READ ...

Page 43: ...ter to indicate whether the scanner must read a bar code one time Level 0 two times Level 1 or three times Level 2 before decoding it A higher level of redundancy ensures the accuracy of a decode in for example poor quality symbols LEVEL 0 LEVEL 1 LEVEL 2 ...

Page 44: ...riminate Response Time This parameter extends the length of time during which the scanner tries to detect which host it is connected to on power up Note When connected to an LS 5700 5800 the 5 second option must be used 1 SECOND default 5 SECONDS ...

Page 45: ...4 15 Parameter Menus Enable Disable UPC E UPC A To enable or disable UPC E or UPC A scan the appropriate bar code below ENABLE UPC E DISABLE UPC E ENABLE UPC A DISABLE UPC A ...

Page 46: ...4 16 LS 2106 Product Reference Guide Enable Disable EAN 8 EAN 13 To enable or disable EAN 8 or EAN 13 scan the appropriate bar code below ENABLE EAN 8 DISABLE EAN 8 ENABLE EAN 13 DISABLE EAN 13 ...

Page 47: ...4 17 Parameter Menus Enable Disable Bookland EAN To enable or disable EAN Bookland scan the appropriate bar code below ENABLE BOOKLAND EAN DISABLE BOOKLAND EAN ...

Page 48: ...is selected and the LS 2106 is presented with a UPC EAN plus supplemental symbol the UPC EAN is decoded and the supplemental characters ignored An autodiscriminate option is also available If this option is selected choose an appropriate Transmit UPC A UPC E Check Digit value from the next page A value of 5 or more is recommended Note In order to minimize the risk of invalid data transmission it i...

Page 49: ...E Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC A or UPC E check digit TRANSMIT UPC A CHECK DIGIT DO NOT TRANSMIT UPC A CHECK DIGIT TRANSMIT UPC E CHECK DIGIT DO NOT TRANSMIT UPC E CHECK DIGIT ...

Page 50: ...ransmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol NO PREAMBLE DATA SYSTEM CHARACTER SYSTEM CHARACTER DATA SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA ...

Page 51: ...ed to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol NO PREAMBLE DATA SYSTEM CHARACTER SYSTEM CHARACTER DATA SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA ...

Page 52: ...a to UPC A format before transmission After conversion data follows UPC A format and be affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E TO UPC A allows you to transmit UPC E zero suppressed decoded data CONVERT UPC E TO UPC A ENABLE DO NOT CONVERT UPC E TO UPC A DISABLE ...

Page 53: ...s parameter is enabled five leading zeros are added to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Disabling this parameter returns EAN 8 symbols to their normal format ENABLE EAN ZERO EXTEND DISABLE EAN ZERO EXTEND ...

Page 54: ...erence Guide EAN Zero Extend Code Type This parameter allows a decoded EAN 8 symbol that has been converted to EAN 13 to be transmitted with either an EAN 13 code type or an EAN 8 code type TYPE IS EAN 13 Default TYPE IS EAN 8 ...

Page 55: ...4 25 Parameter Menus Enable Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below ENABLE CODE 128 DISABLE CODE 128 ...

Page 56: ...4 26 LS 2106 Product Reference Guide Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below ENABLE UCC EAN 128 DISABLE UCC EAN 128 ...

Page 57: ...4 27 Parameter Menus Enable Disable Code 39 To enable or disable Code 39 scan the appropriate bar code below ENABLE CODE 39 DISABLE CODE 39 ...

Page 58: ... enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled ENABLE CODE 39 CHECK DIGIT DISABLE CODE 39 CHECK DIGIT ...

Page 59: ... this symbol if you want to transmit the check digit with the data TRANSMIT CODE 39 CHECK DIGIT ENABLE Do Not Transmit Code 39 Check Digit Scan this symbol if you want to transmit the data without the check digit DO NOT TRANSMIT CODE 39 CHECK DIGIT DISABLE ...

Page 60: ...SPACE and RETURN The other 96 are called printable codes because all but SPACE and DELETE produce visible characters Code 39 Full ASCII interprets the bar code special character preceding a Code 39 character and assigns an ASCII character value to the pair For example when Code 39 Full ASCII is enabled and a B is scanned it is interpreted as b J as and H emulates the keystroke BACKSPACE Scanning A...

Page 61: ...on is selected decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer Scan and Store affects Code 39 decodes only If you select scan and store we recommend that you configure the scanner to decode Code 39 symbology only BUFFER CODE 39 ENABLE DO NOT BUFFER CODE 39 DISABLE While there is data in the transmission buffer deleting Code 39 buffering capability ...

Page 62: ...d buffering See Overfilling Transmission Buffer Unit adds the message excluding the leading space to the transmission buffer No transmission occurs Clear Transmission Buffer To clear the transmission buffer read a symbol which contains only a start character a dash minus and a stop character Unit issues a short hi lo hi beep to signal that the transmission buffer has been erased and no transmissio...

Page 63: ...ng of that decode has occurred by giving a hi lo beep Unit transmits the buffer Unit signals that the buffer has been transmitted with a lo hi beep Overfilling Transmission Buffer If the symbol just read results in an overflow of the transmission buffer Unit indicates that the symbol has been rejected by issuing three long high beeps No transmission occurs Data in buffer is not affected Attempt to...

Page 64: ...4 34 LS 2106 Product Reference Guide Enable Disable Code 93 To enable or disable Code 93 scan the appropriate bar code below ENABLE CODE 93 DISABLE CODE 93 ...

Page 65: ...4 35 Parameter Menus Enable Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5 scan the appropriate bar code below ENABLE INTERLEAVED 2 OF 5 DISABLE INTERLEAVED 2 OF 5 ...

Page 66: ...5 One Discrete Length then scan 1 4 the only I 2 of 5 symbols decoded are those containing 14 characters Numeric bar codes begin on page 4 57 If you make an error or wish to change your selection scan CANCEL on page 4 59 I 2 of 5 ONE DISCRETE LENGTH Two Discrete Lengths This option allows you to decode only those codes containing two selected lengths For example if you select I 2 of 5 Two Discrete...

Page 67: ...of 5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled one length must be set to 14 and the code must have a leading zero and a valid EAN 13 check digit CONVERT I 2 of 5 to EAN 13 ENABLE DO NOT CONVERT I 2 of 5 to EAN 13 DISABLE ...

Page 68: ...4 38 LS 2106 Product Reference Guide Enable Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5 scan the appropriate bar code below ENABLE DISCRETE 2 OF 5 DISABLE DISCRETE 2 OF 5 ...

Page 69: ...rete Length then scan 1 4 the only D 2 of 5 symbols decoded are those containing 14 characters Numeric bar codes begin on page 4 57 If you make an error or wish to change your selection scan CANCEL on page 4 59 D 2 of 5 ONE DISCRETE LENGTH Two Discrete Lengths This option allows you to decode only those codes containing two selected lengths For example if you select D 2 of 5 Two Discrete Lengths t...

Page 70: ...4 40 LS 2106 Product Reference Guide Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below ENABLE CODABAR DISABLE CODABAR ...

Page 71: ...his parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Note Symbol length does not include start and stop characters ENABLE CLSI EDITING DISABLE CLSI EDITING ...

Page 72: ...4 42 LS 2106 Product Reference Guide NOTIS Editing When enabled this parameter strips the start and stop characters from decoded Codabar symbol ENABLE NOTIS EDITING DISABLE NOTIS EDITING ...

Page 73: ...4 43 Parameter Menus Enable Disable MSI Plessey To enable or disable MSI Plessey scan the appropriate bar code below ENABLE MSI PLESSEY DISABLE MSI PLESSEY ...

Page 74: ...heck Digits These check digits at the end of the bar code verify the integrity of the data At least one check digit is always required Check digits are not automatically transmitted with the data ONE MSI Plessey CHECK DIGIT TWO MSI Plessey CHECK DIGIT ...

Page 75: ...s symbol if you want to transmit the check digit with the data TRANSMIT MSI Plessey CHECK DIGIT ENABLE Do Not Transmit MSI Plessey Check Digit Scan this symbol if you want to transmit the data without the check digit DO NOT TRANSMIT MSI Plessey CHECK DIGIT DISABLE ...

Page 76: ...de MSI Plessey Check Digit Algorithm When the two MSI Plessey check digits option is selected an additional verification is required to ensure integrity Either of the two following algorithms may be selected MOD 11 MOD 10 MOD 10 MOD 10 ...

Page 77: ...ter prefix already selected the code ID character is inserted between the prefix and the decoded symbol The user may select no code ID character a Symbol Code ID character or an AIM Code ID character The Symbol Code ID characters are listed below A UPC A UPC E EAN 8 EAN 13 B Code 39 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA J MSI Plessey K UCC EA...

Page 78: ...4 48 LS 2106 Product Reference Guide Transmit Code ID Character SYMBOL CODE ID CHARACTER AIM CODE ID CHARACTER NONE ...

Page 79: ...ues are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table A 1 on page A 1 for conversion information Numeric bar codes begin on page 4 57 If you make an error or wish to change your selection scan CANCEL on page 4 59 SCAN PREFIX SCAN SUFFIX SCAN SUFFIX 2 ...

Page 80: ...4 50 LS 2106 Product Reference Guide Scan Data Transmission Format Use this parameter to change the format of the scanned data DATA AS IS DATA SUFFIX 1 DATA SUFFIX 2 ...

Page 81: ...4 51 Parameter Menus Scan Data Transmission Format cont d DATA SUFFIX 1 SUFFIX 2 PREFIX DATA PREFIX DATA SUFFIX 1 PREFIX DATA SUFFIX 2 PREFIX DATA SUFFIX 1 SUFFIX 2 ...

Page 82: ...4 52 LS 2106 Product Reference Guide Host Interfaces Use these bar codes to select your host interface IBM PC AT IBM PS 2 50 55SX 60 70 80 Default IBM PS 2 30 IBM PC XT NCR 7052 ...

Page 83: ...4 53 Parameter Menus National Keyboard Types Use these bar codes to select the appropriate national keyboard type North American Default French German French International ...

Page 84: ...4 54 LS 2106 Product Reference Guide Spanish Italian Swedish British ...

Page 85: ...ystems may require a slower transmission method If your system still needs additional time to process keyboard dat after setting an Intercharacter Delay scan the DISABLE FAST TRANSMIT bar code ENABLE FAST TRANSMIT DISABLE FAST TRANSMIT Default ...

Page 86: ...host system time to service its receiver and perform other tasks between characters The delay period can range from no delay to 99 msec in 1 msec increments After scanning the bar code below scan two bar codes beginning on page 4 57 to set the desired time out If you make an error or wish to change your selection scan CANCEL on page 4 59 INTERCHARACTER DELAY ...

Page 87: ...4 57 Parameter Menus Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1 2 3 ...

Page 88: ...4 58 LS 2106 Product Reference Guide Numeric Bar Codes cont d 4 5 6 7 8 ...

Page 89: ...4 59 Parameter Menus Numeric Bar Codes cont d 9 Cancel If you make an error or wish to change your selection scan the bar code below CANCEL ...

Page 90: ...with scanners that support data formatting To program the prefix suffix values see the bar codes on page 4 49 Figure 4 1 IBM PC XT Keyboard Figure 4 2 IBM PC AT Keyboard 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7009 7014 7008 7013 7012 7004 7011 7002 7003 7006 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7009 7008 7013 7012 7004 7011 7003 7002 7014 ...

Page 91: ... 7008 7014 7018 7015 7005 7011 7012 7003 6042 6047 6058 6045 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 7006 7001 7010 3023 Normal CNTRL 6043 7013 5007 5008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 5001 5017 7013 5011 7013 if double key 1048 if double key 1048 5012 5009 ...

Page 92: ...008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 1086 1087 1088 1089 1090 5001 1066 1072 1073 1079 1080 1065 1070 1076 1077 1083 1084 1071 1078 1085 1069 5017 7013 5011 1082 1075 1068 1067 1043 if double key 1048 if double key 1048 5012 5009 1074 1081 ...

Page 93: ...cter Set ASCII Value Full ASCII Code 39 Encode Char Keystroke 1000 U CTRL 2 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H 1009 I CTRL I 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M ...

Page 94: ... R CTRL R 1019 S CTRL S 1020 T CTRL T 1021 U CTRL U 1022 V CTRL V 1023 W CTRL W 1024 X CTRL X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D E 1037 E 1038 F 1039 G 1040 H Table A 1 ASCII Character Set Continued ...

Page 95: ... J 1043 K 1044 L 1045 1046 1047 1048 0 0 1047 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C Table A 1 ASCII Character Set Continued ...

Page 96: ...1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N Table A 1 ASCII Character Set Continued ...

Page 97: ...98 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y Table A 1 ASCII Character Set Continued ...

Page 98: ...ndefined 1128 ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R Table A 1 ASCII Character Set Continued ...

Page 99: ... W 2088 ALT X 2089 ALT Y 2090 ALT Z 2091 ALT 2092 ALT 2093 ALT 2094 ALT 6 2095 ALT Misc Key Keystroke 3001 PA 1 3002 PA 2 3003 CMD 1 3004 CMD 2 3005 CMD 3 3006 CMD 4 3007 CMD 5 3008 CMD 6 3009 CMD 7 3010 CMD 8 3011 CMD 9 3012 CMD 10 3013 Table A 1 ASCII Character Set Continued ...

Page 100: ... 2 3019 3020 3021 3022 0 00 PF Keys Keystrokes 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010 PF 10 4011 PF 11 4012 PF 12 4013 PF 13 4014 PF 14 4015 PF 15 4016 PF 16 4017 PF 17 Table A 1 ASCII Character Set Continued ...

Page 101: ...21 PF 21 4022 PF 22 4023 PF 23 4024 PF 24 F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 Table A 1 ASCII Character Set Continued ...

Page 102: ... F22 5023 F23 5024 F24 5025 F25 5026 F26 5027 F27 5028 F28 5029 F29 5030 F30 5031 F31 5032 F32 5033 F33 5034 F34 5035 F35 5036 F36 5037 F37 5038 F38 5039 F39 5040 F40 Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 Table A 1 ASCII Character Set Continued ...

Page 103: ... 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock 6060 00 Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert Table A 1 ASCII Character Set Continued ...

Page 104: ...A 12 LS 2106 Product Reference Guide 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow 7019 Back Tab Table A 1 ASCII Character Set Continued ...

Page 105: ... code symbol Bar Code Density The number of characters represented per unit of measurement e g characters per inch Bar Height The dimension of a bar measured perpendicular to the bar width Bar Width Thickness of a bar measured from the edge closest to the symbol start character to the trailing edge of the same bar Baud Rate A measure of the data flow or number of signaling events occurring per sec...

Page 106: ...number letter punctuation mark or communications control contained in a message Character Set Those characters available for encodation in a particular bar code symbology Check Digit A digit used to verify a correct symbol decode The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit Check digits are required for UPC but...

Page 107: ...symbol in which the spaces between characters intercharacter gaps are not part of the code Discrete 2 of 5 A binary bar code symbology representing each character by a group of five bars two of which are wide The location of wide bars in the group determines which character is encoded spaces are insignificant Only numeric characters 0 to 9 and START STOP characters may be encoded EAN European Arti...

Page 108: ...ulated Emission of Radiation The laser is an intense light source Light from a laser is all the same frequency unlike the output of an incandescent bulb Laser light is typically coherent and has a high energy density Laser Diode A gallium arsenide semiconductor type of laser connected to a power source to generate a laser beam This laser type is a compact source of coherent light LED Indicator A s...

Page 109: ...istinguished by a particular reading device or printed with a particular device or method Scan Area Area intended to contain a symbol Scanner An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol Its three main components are 1 Light source laser or photoelectric cell illuminates a bar code 2 Photodetector registers...

Page 110: ... the outside edges of the quiet zones of the first row and the last row Symbol Length Length of symbol measured from the beginning of the quiet zone margin adjacent to the start character to the end of the quiet zone margin adjacent to a stop character Symbology The structural rules and conventions for representing data within a particular bar code type e g UPC EAN Code 39 Tolerance Allowable devi...

Page 111: ...using this manual Did this manual meet your needs If not please explain __________________ ____________________________________________________________________ ____________________________________________________________________ What topics need to be added to the index if applicable __________________ ____________________________________________________________________ What topics do you feel nee...