background image

Product Reference Guide

LS 5700/LS 5800

Summary of Contents for LS 5700

Page 1: ...Product Reference Guide LS 5700 LS 5800 ...

Page 2: ...70 16692 03 Revision A May 2003 Symbol Technologies Inc One Symbol Plaza Holtsville N Y 11742 ...

Page 3: ...LS 5700 5800 Product Reference Guide 70 16692 03 Revision A May 2003 ...

Page 4: ... work from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereunder and to include the same on any authorized copies it makes in whole or in part The user agrees not to decompile disassemble decode or reverse engineer any licensed program delivered to the user ...

Page 5: ...cting Your Scanner 2 4 To an IBM 468x 469x Terminal Port 9E or Port 17 2 4 To an IBM 468x 469x Terminal Port 5B RS 232C or Syn apse Host 2 5 To an RS 232C Host Using the RS 232C Port 2 6 Dual Port RS 232C 2 7 Connecting a Hand Held Laser Scanner 2 8 Electronic Article Surveillance EAS 2 10 EAS Options 2 11 Mounting 2 12 LS 5700 2 12 LS 5800 2 14 Layout 2 15 Stainless Steel Top 2 16 Replacing Other...

Page 6: ...rors While Scanning 3 4 Setting Parameters 3 5 Host Types 3 5 RS 232C Port Options 3 5 Code Types Options 3 5 Custom Tailoring 3 5 Decode Options 3 6 Data Transmission Formats 3 7 Programming Utilities 3 7 Chapter 4 Maintenance and Specifications Routine Maintenance 4 1 LS 5700 4 1 LS 5800 4 2 Accessories 4 3 Technical Specifications 4 4 Beeper Definitions 4 8 Chapter 5 Parameter Menus Set Default...

Page 7: ...9 Baud Rate 5 20 Parity 5 28 Check Parity 5 33 Do Not Check Parity 5 34 Hardware Handshaking 5 35 Software Handshaking 5 42 Serial Response Time out 5 47 Stop Bit Select 5 48 ASCII Format 5 50 Serial Host RTS Line State 5 52 Beep on BEL 5 54 Do Not Beep on BEL 5 55 RS 232C Port Auxiliary Options 5 56 Baud Rate 5 57 Parity 5 65 Check Parity 5 70 Do Not Check Parity 5 71 Hardware Handshaking 5 72 So...

Page 8: ...e Types Options 5 92 UPC A 5 92 Disable UPC A 5 93 UPC E 5 94 Disable UPC E 5 95 EAN 8 5 96 Disable EAN 8 5 97 EAN 13 5 98 Disable EAN 13 5 99 Bookland EAN 5 100 Disable Bookland EAN 5 101 Decode UPC EAN Supplementals 5 102 Ignore UPC EAN With Supplementals 5 103 Autodiscriminate UPC EAN With Supplementals 5 104 UCC EAN Coupon Code 5 105 Disable UCC EAN Coupon Code 5 106 Random Weight Check Digit ...

Page 9: ...5 5 126 Disable I 2 of 5 5 127 Set Lengths for Interleaved 2 of 5 5 128 Set Lengths for Interleaved 2 of 5 5 129 Set Lengths for Interleaved 2 of 5 5 130 Set Lengths for Interleaved 2 of 5 5 131 I 2 of 5 Check Digit Verification USS 5 132 OPCC Check Digit Verification OPCC 5 133 I 2 of 5 Check Digit Verification 5 134 Codabar 5 135 Disable Codabar 5 136 Set Lengths for Codabar 5 137 CLSI Editing 5...

Page 10: ...ock 5 169 Reject Predecode Block 5 170 Accept Predecode Block 5 171 UPC EAN Security Level 5 172 Linear UPC EAN Decode 5 176 Disable Linear UPC EAN Decode 5 177 Linear Supplemental Decode 5 178 Disable Linear Supplemental Decode 5 179 Decode Redundancy for UPC EAN only in Autodiscriminate Mode 5 180 UPC EAN Decode Performance 5 181 Disable UPC EAN Decode Performance 5 182 UPC EAN Decode Performanc...

Page 11: ...5 to EAN 13 5 216 Do Not Convert I 2 of 5 to EAN 13 5 217 Transmit I 2 of 5 Check Digit 5 218 Do Not Transmit I 2 of 5 Check Digit 5 219 Transmit Code 39 Check Digit 5 220 Do Not Transmit Code 39 Check Digit 5 221 Beep After Good Decode 5 222 Do Not Beep After Good Decode 5 223 Intercharacter Delay 5 224 Transmit Code ID Character 5 225 Transmit AIM Code ID Character 5 226 Do Not Transmit AIM or S...

Page 12: ...viii LS 5700 LS 5800 Product Reference Guide Programming Utilities 5 246 Numeric Bar Codes 5 246 Cancel 5 256 Enter 5 257 Applications Items 5 258 Appendix UCC EAN 128 A 1 AIM Code Identifiers A 3 ...

Page 13: ...The following conventions are used in this document Bullets indicate action items lists of alternatives lists of required steps that are not necessarily sequential Sequential lists e g those that describe step by step procedures appear as numbered lists Related Publications LS 5700 5800 Quick Reference Guide p n 70 16691 xx LS 5800 Mounting EAS Installation Guide p n 70 17856 xx ...

Page 14: ...lem If the equipment is found to be working properly and the problem is symbol readability the Support Center will request samples of your bar codes for analysis at our plant If your problem cannot be solved over the phone you may need to return your equipment for servicing If that is necessary you will be given specific directions Note Symbol Technologies is not responsible for any damages incurr...

Page 15: ...d States 1 Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 1 800 653 5350 Canada Symbol Technologies Canada Inc 2540 Matheson Boulevard East Mississauga Ontario Canada L4W 4Z2 905 629 7226 United Kingdom Symbol Technologies Symbol Place Winnersh Triangle Berkshire RG41 5TP United Kingdom 0800 328 2424 Inside UK 44 118 945 7529 Outside UK ...

Page 16: ... Symbol Technologies Pty Ltd 432 St Kilda Road Melbourne Victoria 3004 1 800 672 906 Inside Australia 61 3 9866 6044 Outside Australia Austria Österreich Symbol Technologies Austria GmbH Prinz Eugen Strasse 70 2 Haus 1040 Vienna Austria 01 5055794 0 Inside Austria 43 1 5055794 0 Outside Austria Denmark Danmark Symbol Technologies AS Dr Neergaardsvej 3 2970 Hørsholm 7020 1718 Inside Denmark 45 7020...

Page 17: ...sinki Finland 9 5407 580 Inside Finland 358 9 5407 580 Outside Finland France Symbol Technologies France Centre d Affaire d Antony 3 Rue de la Renaissance 92184 Antony Cedex France 01 40 96 52 21 Inside France 33 1 40 96 52 50 Outside France Germany Deutchland Symbol Technologies GmbH Waldstrasse 66 D 63128 Dietzenbach Germany 6074 49020 Inside Germany 49 6074 49020 Outside Germany ...

Page 18: ...484441 Outside Italy Latin America Sales Support 2730 University Dr Coral Springs FL 33065 USA 1 800 347 0178 Inside United States 1 954 255 2610 Outside United States 954 340 9454 Fax Mexico México Symbol Technologies Mexico Ltd Torre Picasso Boulevard Manuel Avila Camacho No 88 Lomas de Chapultepec CP 11000 Mexico City DF Mexico 5 520 1835 Inside Mexico 52 5 520 1835 Outside Mexico ...

Page 19: ...stered and mailing address Symbol Technologies Norway Hoybratenveien 35 C N 1055 OSLO Norway Symbol s repair depot and shipping address Symbol Technologies Norway Enebakkveien 123 N 0680 OSLO Norway 47 2232 4375 South Africa Symbol Technologies Africa Inc Block B2 Rutherford Estate 1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11 809 5311 Inside South Africa 27 11 809 5311 Outs...

Page 20: ...0 00 Outside Spain Fax 34 91 324 4010 Sweden Sverige Letter address Symbol Technologies AB Box 1354 S 171 26 SOLNA Sweden Visit shipping address Symbol Technologies AB Solna Strandväg 78 S 171 54 SOLNA Sweden Switchboard 08 445 29 00 domestic Call Center 46 8 445 29 29 international Support E Mail Sweden Support se symbol com 1 Customer support is available 24 hours a day 7 days a week ...

Page 21: ...vii About This Manual If you purchased your Symbol product from a Symbol Business Partner contact that Business Partner for service For the latest version of this guide go to http www symbol com manuals ...

Page 22: ...xviii LS 5700 LS 5800 Product Reference Guide ...

Page 23: ...endicular to the face of the scanner The LS 5800 is designed for in counter mounting It allows slide through scanning of items thereby enhancing productivity and throughput The LS 5700 and LS 5800 scanners Figure 1 1 are identical electrically and provide the same reliable scanning capabilities In instances where no distinction is drawn between the LS 5700 and LS 5800 they will be collectively ref...

Page 24: ...Check Digit UCC 128 Coupon Code Bookland EAN 13 and ITF 14 are supported In most instances changing host systems is as easy as scanning the appropriate bar code and changing the cable The scanner provides connection for an optional Synapse compatible hand held scanner such as an LS 4004 The hand held scanner allows you to scan heavy items without lifting them Some scanner models have an integrated...

Page 25: ...ed with the shipment Scanner Power supply or power cable if applicable RS 232C Host interface cable or Synapse Adapter cable and Synapse cable Quick Reference Guide Figure 2 1 Items Contained in a Typical Scanner Package Cables Synapse Synapse Adapter Power Supply Synapse Power Adapter RS 232 LS 5700 LS 5800 Quick Reference Guide Power Supply ...

Page 26: ...or was damaged in transit call the Symbol Support Center at the telephone number listed on page xi KEEP THE PACKING It is the approved shipping container and should be used if you ever need to return your equipment for servicing Input Output Ports The scanner contains the ports as shown in Figure 2 2 Figure 2 2 Input Output Ports Power In Port When external power is required the input to this port...

Page 27: ...rogram the LS 5700 LS 5800 and adapts itself to the LS 5700 LS 5800 decode parameters i e code types lengths and check digits A separate AC adapter may be necessary when using a hand held scanner Current draw on this port should not exceed 200 mA RS 232C Port A 10 pin modular connector This input output port is used to connect the scanner to an RS 232C host It is also used as an auxiliary port to ...

Page 28: ...een the Power Regulator cable and the IBM terminal No additional power supply is needed as the IBM terminal supplies power to the scanner If additional scanning versatility is desired plug a Synapse compatible scanner into the Hand Held Laser Scanner port Figure 2 3 Connecting to an IBM Terminal Port 9E or Port 17 In this configuration the scanner draws power from the host LS 5700 LS 5800 IBM 468x...

Page 29: ...nd to the host terminal Attach the power supply to the Power port If additional scanning versatility is desired plug a Synapse compatible scanner into the Hand Held Laser Scanner port Figure 2 4 Figure 2 4 Connecting to an IBM Terminal Port 5B RS 232C In this configuration an external power supply is required LS 5700 LS 5800 Host Terminal Synapse Cable Synapse Adapter Cable p n 25 17072 01 Power ...

Page 30: ...C port and the other to the host Attach the power supply to the Power port If additional scanning versatility is desired plug a Synapse compatible scanner into the Hand Held Laser Scanner port Figure 2 5 Figure 2 5 Connecting to an RS 232C Host In this configuration an external power supply is required LS 5700 LS 5800 RS 232 Host Power ...

Page 31: ...232C device Attach the power supply to the Power port If additional scanning versatility is desired plug a Synapse compatible scanner into the Hand Held Laser Scanner port Figure 2 6 Figure 2 6 Dual Port RS 232C In this configuration an external power supply is required LS 5700 LS 5800 RS 232 Host Terminal Synapse Cable Synapse Adapter Cable p n 25 17072 01 Power Auxiliary RS 232 Device ...

Page 32: ...ameters Any changes to the primary scanner s settings are automatically reflected back to the hand held scanner Programming bar codes are provided to program only the hand held laser scanner program only the LS 5700 LS 5800 program both scanners simultaneously If you are using a Symbol LS 2603MX LS 3603MX or LS 3203 hand held scanner different bar codes are used to set these programming modes They...

Page 33: ...the scanner into the Scanner port Using the hand held scanner scan a parameter bar code If the primary scanner issues a warble beep the hand held scanner you have supports the programming modes If the hand held scanner issues a warble beep it does not support these modes ...

Page 34: ...ere some customers are favored and not all items are scanned The interlock prohibits the deactivation of the EAS tag without the item being scanned first Do not attempt to activate the interlock feature yourself The following instructions are for a Symbol qualified technician only 1 Peel off the EAS sticker on the scanner 2 Open the scanner and run the EAS Interlock cable through the hole where th...

Page 35: ... offering EAS Complete mounting instructions and details are provided in the LS 5800 Mounting Instructions and EAS Installation Guide Table 2 1 EAS Options Option Model Number Bucket or Kit Number Internal LS 5700 I000GC Not Applicable Internal LS 5800 I20xTC 12 17206 02 External LS 5800 I21xSN KT 19430 01 External LS 5800 I21xDN KT 19430 01 Internal LS 5800 I210SC Not Applicable ...

Page 36: ...Figure 2 7 represents the active scan area or the area in which a bar code is decoded Figure 2 7 LS 5700 Active Scan Area For added stability the LS 5700 can also be mounted in a stand 1 Attach the stand to the counter top or other stable base Secure with three screws Figure 2 8 Figure 2 8 Attaching the Stand to the Counter Top Screws ...

Page 37: ... the front of the scanner under the front lip of the stand Figure 2 9 Figure 2 9 Placing the LS 5700 into the Stand 3 Push the rear of the scanner down until it snaps into place Figure 2 10 Figure 2 10 Seating the Scanner ...

Page 38: ...with the counter top or resting on it The dotted area in Figure 2 11 depicts the active scan area and the arrow shows the optimal direction of product flow The scanner s active scan zone extends about 6 in 15 24 cm above the window and is angled at approximately 38 from the counter Figure 2 11 LS 5800 Active Scan Area symbol Product Flow ...

Page 39: ...cm away laterally Figure 2 12 Typical LS 5800 Installation LS 5800 IXXXTN and LS 5800 IXXXTC models have a Tempax Scratch Resistant glass window An in counter mounting kit is required for these models Instructions for mounting can be found in the LS 5800 Mounting EAS Installation Guide Cable Routing Synapse Cable I F Cable 66 5 in 1690 mm 71 2 in 1810 mm Host Power Supply Scanner ...

Page 40: ...teel Top with a Sapphire glass The LS 5800 I210SC has a Stainless Steel Top with a Sapphire glass and is EAS ready There are two options for mounting the LS 5800 with a Stainless Steel Top Option A Resting on the counter top Note Not applicable to the LS 5800 I210SC configuration 1 Cut a hole in the counter 6 81 in 173 mm square Figure 2 13 Stainless Steel Top Option A Counter Hole 6 81 in 0 06 17...

Page 41: ...r top 1 On the counter top measure two concentric squares an inside square of 6 81 in 173 mm and an outside square of 7 91 in 201 mm Figure 2 14 2 Cut out the 6 81 in 173 mm inner square 3 With a router set to the appropriate depth route out the outside square The corner radius should not exceed 0 20 in 5 mm LS 5800 I210DN depth 0 05in 1 2mm LS 5800 I210SN depth 0 05in 1 2mm ...

Page 42: ...5100 LS 5400 with LS 5800 I220SN 1 Remove the LS 5100 LS 5400 scanner 2 Place the LS 5800 IxxxZN or LS 5800 I220SN scanner on the counter near the hole 3 Route the cables from beneath the hole and attach to the scanner as shown in Figure 2 12 0 05 in 1 2 mm 0 39 in min 10 mm min R 0 20 in max R 5 mm max 7 91 in min 201 mm min Counter Hole 6 81 in 0 06 173 mm 1 5 7 91 in 201 mm 3 5 in 89 mm 0 27 in...

Page 43: ...2 19 Set Up 4 Lower the scanner into the hole Figure 2 15 Replacement Bucket 10 63 in min 270 mm min 4 63 in 118 mm Counter Hole 7 5 in 191 mm ...

Page 44: ... 5700 has a push button near the top right corner This push button is to adjust both the volume and tone of the beeper and to wake the scanner from its Rest or Sleep mode When the scanner is operating depress this button to adjust the volume tone Hold down the button until the desired sound is obtained There are five distinct volume tone combinations Each combination beeps two times before cycling...

Page 45: ...2 21 Set Up Figure 2 16 LS 5700 Controls Speaker Volume Control Wake Up Switch Decode Indicator Sleep Mode Error Mode Indicator Window Removal Latch ...

Page 46: ...Reference Guide LS 5700 Connectors Removing the connector cover will allow access to the scanner s connectors Figure 2 17 Figure 2 17 LS 5700 Connectors Scanner Port EAS Antenna Optional Host Port RS 232C Port Connector Cover Power ...

Page 47: ...d be free of any designs e g stripes or patterns Ideally that area should be a light solid color To scan a bar code move an item through the active scan area in the direction of the arrows with the bar code label facing the scan window Figure 3 1 The scanner beeps when a bar code has been decoded successfully Figure 3 1 Scanning Bar Codes symbol ...

Page 48: ...e saves power and extends the life of the scanner The scanner automatically awakens as soon as you pass a bar coded item in front of the scan window The LS 5700 also has a programmable shut down Sleep option that turns off the laser and the motor The scanner can be awakened from this mode or the Rest mode by momentarily depressing the push button on the top right corner When you press this button ...

Page 49: ...hat you ve scanned a host type Check for loose cable connections Make certain the code type you re trying to decode is enabled and that it is supported by your host Check the symbol to make sure it is of suitable quality not damaged Try scanning similar symbols of the same code type Be sure you re using the proper power supply Note If after performing these checks the symbol still does not scan co...

Page 50: ...equence Examples In most cases you need only scan one bar code to set a specific parameter For example if you want to set the baud rate to 9600 simply scan the 9600 bar code listed under BAUD RATE The scanner issues a warble tone signifying a successful parameter entry If you want to enable or disable prefixes and suffixes or customize the data transmission format you have to scan several bar code...

Page 51: ...a Synapse Smart Cable a programming sheet containing a host bar code is packaged with the cable Select your host type using that bar code RS 232C Port Options Serial RS 232C data can be modified to meet host requirements Code Types Options Enable or disable host supported code types and options such as UPC or EAN supplementals and selectable code lengths Custom Tailoring Customize any combination ...

Page 52: ...ing continues during a scan attempt Power down or Rest mode Select how long the scanner remains on during periods of inactivity On the LS 5700 you can also select a Sleep mode Decode Options Reject Predecode Block Added security against accidental misdecodes caused by an operator bringing similar but not identical items into the scanners field of view simultaneously When enabled the scanner reject...

Page 53: ...a host compatible format prior to transmission Transmit Check Digits Preambles Prefix Suffix values Transmit Code ID Character Ignore Unknown Characters Programming Utilities This section contains numeric bar codes used to quantify certain options application specific bar codes Enter and Cancel bar codes ...

Page 54: ...3 8 LS 5700 LS 5800 Product Reference Guide ...

Page 55: ... particles with a damp cloth Wipe the window with a tissue moistened with ammonia water LS 5700 To change or clean the exit window Press window removal latch and rotate forward Figure 4 1 Figure 4 1 Removing window from an LS 5700 To Clean Wipe clean the underside of the upper window Wipe clean the top surface of the lower window Re install the window by snapping into place Window Removal Latch ...

Page 56: ...e large screw heads on the front of the scanner and turn counter clockwise Figure 4 2 Figure 4 2 Removing Window from an LS 5800 Lift off the window To Clean Wipe clean the underside of the upper window Wipe clean the top surface of the lower window Re install the top cover by tightening the two large screws ...

Page 57: ...e available from Symbol Technologies See your Symbol representative or re seller for ordering information LS 5700 Mounting Stand LS 5800 In counter Mounting Kit LS 5800 Stainless steel top plate with various hardened window options LS 5700 LS 5800 External Beeper Competitive Scanner Adapter Kit EAS Antenna kit Pre loaded on some models Add on kit for either model Contact your Symbol representative...

Page 58: ...irection dynamic cross pattern Angular Orientation Yaw Roll Pitch LS 5700 LS 5800 45 to 45 360 30 to 60 0 to 90 Decode Depth of Field On 100 UPC symbols See Table 4 2 Print Contrast Minimum 25 absolute dark light reflectance differential measured at 675 nm Ambient Light Immunity Fluorescent Incandescent Mercury Vapor Sodium Vapor Sunlight 450 ft candles 4844 lux 450 ft candles 4844 lux 450 ft cand...

Page 59: ...LS 5800 1 9 lbs 86 kg 1 8 lbs 81 kg Dimensions LS 5700 Depth Height Width LS 5800 3 82 in 9 7 cm 6 2 in 15 7 cm 5 97 in 15 2 cm See Table 4 3 Cable Length 6 ft 183 cm LS 5700 LS 5800 Full Range 10 in 25 4 cm 6 7 in 17 0 cm Medium Range 7 0 in 17 8 cm 6 0 in 15 2 cm Short Range 3 5 in 8 9 cm 3 5 in 8 9 cm Decode range depends on contrast density orientation and quality of the bar code being decoded...

Page 60: ...1 7 62 6 15 24 6 15 24 5 x 5 12 7 x 12 7 LS 5800 I200TC Tempax 3 1 7 62 6 15 24 6 15 24 5 x 5 12 7 x 12 7 LS 5800 I210DN Diamond coated 3 3 8 4 7 9 20 1 7 9 20 1 4 6 x 5 1 11 7 x 12 9 LS 5800 I210SN Sapphire coated 3 3 8 4 7 9 20 1 7 9 20 1 4 x 5 10 2 x 12 7 LS 5800 I220SN Sapphire coated 3 3 8 4 11 8 30 8 8 22 3 5 x 4 12 7 x 10 2 LS 5800 I210SC Sapphire coated 3 3 8 4 11 8 30 8 8 22 3 5 x 4 12 7 ...

Page 61: ... Bucket Dimensions Model Top Plate Width Length In In cm cm Depth In cm Standard 12 17206 xx 7 87 200 7 87 200 3 16 80 2 LS 5000 Replacement 12 17207 xx 8 5 216 11 65 296 3 16 80 2 Spectra Physics Freedom Adaptor 12 17208 xx 11 3 287 14 37 365 3 16 80 2 ...

Page 62: ...urned on or after a system reset indicating the system software is working properly If three beeps occur during normal operation it is due to a reset any work in progress is lost If this occurs often contact the Symbol Support Center 4 Beeps long high tone A format or transmission error has been detected in the serial data or in a scanned symbol The data is ignored This occurs if a unit is not pro...

Page 63: ...ne Keyboard parameter selected Enter value using bar code keypad Hi lo hi lo tone Successful program exit with change in the parameter setting Serial Communication 1 Beep short high tone Serial communication was successfully received then transmitted to the host 4 Beeps short high tone Serial communications error Hi hi hi hi Parity error Table 4 5 Beeper Definitions cont d Beeper Sequence Indicati...

Page 64: ...4 10 LS 5700 LS 5800 Product Reference Guide ...

Page 65: ...ing 5 42 to 5 46 Serial Response Time out 5 47 Stop Bit Select 5 48 to 5 49 ASCII Format 5 50 to 5 51 Serial Host RTS Line State 5 52 to 5 53 Beep on BEL 5 54 to 5 55 RS 232C Port Auxiliary Options 5 56 to 5 84 Baud Rate 5 57 to 5 64 Parity 5 65 to 5 69 Check Parity 5 70 to 5 71 Hardware Handshaking 5 72 to 5 75 Software Handshaking 5 76 to 5 77 Serial Response Time out 5 78 Stop Bit Select 5 79 t...

Page 66: ...d EAN Supplementals 5 96 to 5 104 UCC EAN Coupon Code 5 105 to 5 106 Random Weight Check Digit 5 107 to 5 109 Code 128 5 110 to 5 114 Code 39 5 115 to 5 125 I 2 of 5 5 126 to 5 134 Codabar 5 135 to 5 144 Custom Tailoring 5 145 to 5 168 Scanning Range 5 145 to 5 147 Internal Beeper 5 148 to 5 149 RS 232C Port External Beeper 5 150 to 5 151 Beeper Volume 5 152 to 5 154 Beeper Frequency 5 155 to 5 15...

Page 67: ...PC A Check Digit 5 200 to 5 201 UPC E Check Digit 5 202 to 5 203 UPC A Preamble 5 204 to 5 207 UPC E Preamble 5 208 to 5 209 Convert UPC E to UPC A 5 210 to 5 211 EAN Zero Extend 5 212 to 5 213 Convert EAN 8 to EAN 13 Type 5 214 to 5 215 Convert I 2 of 5 to EAN 13 5 216 to 5 217 Transmit I 2 of 5 Check Digit 5 218 to 5 219 Transmit Code 39 Check Digit 5 220 to 5 221 Beep After Good Decode 5 222 to...

Page 68: ...5 4 LS 5700 LS 5800 Product Reference Guide Programming Utilities 5 246 to 5 264 Numeric Bar Codes 5 246 to 5 255 Cancel 5 256 Enter 5 257 Application Items 5 258 to 5 264 ...

Page 69: ...5 5 Parameter Menus Set Default Parameter Scanning this bar code returns all parameters to the values listed in the Default Table beginning on page 5 6 SET ALL DEFAULTS ...

Page 70: ...are Handshaking None 5 37 Software Handshaking None 5 42 Serial Response Time out 2 0 seconds 5 47 Stop Bit Select One 5 49 ASCII Format 8 Bit 5 50 Host Serial Line State High 5 53 Beep on BEL Disable 5 55 RS 232C Port Auxiliary Options Baud Rate 9600 5 63 Parity Even 5 66 Check Parity Enable 5 70 Hardware Handshaking None 5 74 Software Handshaking None 5 76 Serial Response Time out 2 0 seconds 5 ...

Page 71: ...E Enable 5 94 EAN 8 Enable 5 96 EAN 13 Enable 5 98 Bookland EAN Disable 5 101 Decode UPC EAN Supplementals Ignore 5 102 UPC EAN Coupon Code Disable 5 106 Random Weight Check Digit Disable 5 107 Code 128 Enable 5 110 UCC EAN 128 Enable 5 112 Lengths for Code 128 Any Length 5 114 Code 39 Enable 5 115 Code 39 Full ASCII Conversion Disable 5 119 Set Length s for Code 39 5 to 55 5 120 Code 39 Check Dig...

Page 72: ... 5 144 Custom Tailoring Scanning Range Full 5 145 Internal Beeper Enable 5 148 RS 232C Port External Beeper Disable 5 151 Beeper Volume High 5 154 Beeper Frequency High 5 157 Time out between reads same symbol 0 6 seconds 5 158 Time out between reads different symbols 0 2 seconds 5 159 Decode Buffering Disable 5 161 Time Delay to Rest Sleep Mode 30 minutes 5 165 Primary Decode Session Time 2 0 sec...

Page 73: ...le Level 3 5 185 Linear Code Type Security Level 1 5 186 Code 128 Decode Performance Enable Level 3 5 194 Code 39 Decode Performance Enable Level 3 for fixed length only 5 199 Data Transmission Formatting Transmit UPC A Check Digit Enable 5 200 Transmit UPC E Check Digit Enable 5 202 UPC A Preamble System Char 5 205 UPC E Preamble System Char 5 208 Convert UPC E to A Disable 5 211 EAN 8 Zero Exten...

Page 74: ...e 5 221 Beep After Good Decode Enable 5 222 Intercharacter Delay 0 5 224 Transmit Code ID Character None 5 227 Pause Duration 0 5 228 Prefix Suffix Values 7013 CR LF for serial 5 229 Scan Data Transmission Format Data as is 5 234 Serial Data Transmission Format Data as is 5 239 Ignore Unknown Characters Enable 5 243 Table 5 1 Default Table cont d ...

Page 75: ...5 11 Parameter Menus EAS Interlock Enable EAS Interlock When enabled the EAS tag is not de activated until the associated bar code is decoded ENABLE EAS INTERLOCK ...

Page 76: ...5 12 LS 5700 LS 5800 Product Reference Guide EAS Interlock Disable EAS Interlock When disabled default the EAS tag is de activated independently of any bar code scanning DISABLE EAS INTERLOCK ...

Page 77: ...arameter Menus RS 232C Host Types Select a Host Interface from the list below then scan the corresponding bar code Host Interface Page No Host 5 14 RS 232C Single Port 5 15 Nixdorf 5 16 ICL 5 17 Fujitsu 5 18 ...

Page 78: ...5 14 LS 5700 LS 5800 Product Reference Guide RS 232C Host Types No Host When this bar code is scanned the scanner decodes a bar code but does not transmit the data to the host NO HOST ...

Page 79: ...5 15 Parameter Menus RS 232C Host Types Single Port RS 232C Host SINGLE PORT RS 232C HOST ...

Page 80: ...5 16 LS 5700 LS 5800 Product Reference Guide RS 232C Host Types Nixdorf RS 232C Host Nixdorf RS 232C HOST ...

Page 81: ...5 17 Parameter Menus RS 232C Host Types ICL RS 232C Host ICL RS 232C HOST ...

Page 82: ...5 18 LS 5700 LS 5800 Product Reference Guide RS 232C Host Types Fujitsu RS 232C Host Fujitsu RS 232C HOST ...

Page 83: ...ost on page 5 15 or one of the terminal specific RS 232C Host bar codes on pages 5 16 to 5 18 3 Use the programming bar codes on pages 5 20 to 5 55 to set the applicable parameters To use the RS 232C port as an auxiliary input port see page 5 56 If you are using an RS 232C host single or dual port connected to the Host port with a Synapse Smart Cable and you wish to change any of the host paramete...

Page 84: ...mitted per second The scanner s baud rate setting should match the data rate setting of the host device If not data may not reach the host device or may reach it in distorted form To select a baud rate of 110 scan the bar code below To select other baud rates scan the corresponding bar code on the following pages BAUD RATE 110 ...

Page 85: ...5 21 Parameter Menus RS 232C Port Host Options Baud Rate BAUD RATE 300 ...

Page 86: ...5 22 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Baud Rate BAUD RATE 600 ...

Page 87: ...5 23 Parameter Menus RS 232C Port Host Options Baud Rate BAUD RATE 1200 ...

Page 88: ...5 24 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Baud Rate BAUD RATE 2400 ...

Page 89: ...5 25 Parameter Menus RS 232C Port Host Options Baud Rate BAUD RATE 4800 ...

Page 90: ...5 26 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Baud Rate BAUD RATE 9600 ...

Page 91: ...5 27 Parameter Menus RS 232C Port Host Options Baud Rate BAUD RATE 19200 ...

Page 92: ...rt Host Options Parity A parity check bit is the most significant bit of each ASCII coded character Odd If you select ODD parity the parity bit has a value 0 or 1 based on data to ensure than an odd number of 1 bits are contained in the coded character ODD ...

Page 93: ...arameter Menus RS 232C Port Host Options Parity Even If you select EVEN parity the parity bit has a value 0 or 1 based on data to ensure than an even number of 1 bits are contained in the coded character EVEN ...

Page 94: ...5 30 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Parity Mark Select MARK parity and the parity bit is always 1 MARK ...

Page 95: ...5 31 Parameter Menus RS 232C Port Host Options Parity Space Select SPACE parity and the parity bit is always 0 SPACE ...

Page 96: ...5 32 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Parity None If no parity is required select NONE NONE ...

Page 97: ...33 Parameter Menus RS 232C Port Host Options Check Parity Select whether or not the parity of received characters is checked The type of parity used is selectable through the PARITY parameter CHECK PARITY ...

Page 98: ...5 34 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Do Not Check Parity DO NOT CHECK PARITY ...

Page 99: ...2 seconds for the host to negate the CTS line If after 2 seconds the CTS line is still asserted the scanner sounds a transmit error and any scanned data is lost When the CTS line is negated the controller asserts the RTS line and waits up to 2 seconds for the host to assert CTS When the host asserts CTS data is transmitted If after 2 seconds the CTS line is not asserted the scanner sounds a transm...

Page 100: ...d be asserted If CTS is de asserted for more than 50 msec between characters the transmission is aborted the scanner sounds a transmission error and the data is discarded If the above communications sequence fails the scanner issues an error indication In this case the data is lost and must be rescanned Note The DTR signal is jumpered active ...

Page 101: ...5 37 Parameter Menus RS 232C Port Host Options Hardware Handshaking None Scan the bar code below if no Hardware Handshaking is desired NONE ...

Page 102: ...5 38 LS 5700 LS 5800 Product Reference Guide RS 232C Port Host Options Hardware Handshaking Standard Scan the bar code below to select Standard RTS CTS Hardware Handshaking STANDARD RTS CTS ...

Page 103: ...Host Options Hardware Handshaking RTS CTS Option 1 When RTS CTS Option 1 is selected the scanner asserts RTS before transmitting and ignores the state of CTS The scanner de asserts RTS when the transmission is complete RTS CTS OPTION 1 ...

Page 104: ...ng RTS CTS Option 2 When Option 2 is selected RTS is always high or low user programmed logic level However the scanner waits for CTS to be asserted before transmitting data If CTS is not asserted within 2 seconds the scanner issues an error indication and discards the data RTS CTS OPTION 2 ...

Page 105: ...e scanner asserts RTS prior to any data transmission regardless of the state of CTS The scanner waits up to 2 seconds for CTS to be asserted If CTS is not asserted during this time the scanner issues an error indication and discards the data The scanner de asserts RTS when transmission is complete RTS CTS OPTION 3 ...

Page 106: ...RS 232C Port Host Options Software Handshaking This parameter offers control of the data transmission process in addition to or instead of that offered by hardware handshaking NONE When this option is selected data is transmitted immediately NONE ...

Page 107: ...ts the same data again and waits for either an ACK or NAK After three unsuccessful attempts to send data when NAKs are received the scanner issues an error indication and discards the data The scanner waits up to the programmable Host Serial Response Time out to receive an ACK or NAK If the scanner does not get a response in this time it issues an error indication and discards the data There are n...

Page 108: ...his option is selected the scanner waits for an ENQ character from the host before transmitting data If an ENQ is not received within 2 seconds the scanner issues an error indication and discards the data The host must transmit an ENQ character at least every 2 seconds to prevent transmission errors ENQ ...

Page 109: ...5 45 Parameter Menus RS 232C Port Host Options Software Handshaking ACK NAK with ENQ This combines the 2 previous options ACK NAK with ENQ ...

Page 110: ... send When the scanner has data to send it then waits for an XON character before transmission The scanner waits up to 2 seconds to receive the XON If the XON is not received within this time the scanner issues an error indication and discards the data XOFF is received during a transmission Data transmission then stops after sending the current byte When the scanner receives an XON character it se...

Page 111: ...mines the maximum period allowed to elapse before the scanner assumes end of transmission The delay period can range from 0 0 to 9 9 seconds in 1 second increments After scanning the bar code below scan two bar codes on pages 5 246 to 5 255 to set the desired time out SERIAL RESPONSE TIME OUT ...

Page 112: ...d character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to match those device requirements 1 STOP BIT ...

Page 113: ...5 49 Parameter Menus RS 232C Port Host Options Stop Bit Select 2 STOP BITS ...

Page 114: ...5800 Product Reference Guide RS 232C Port Host Options ASCII Format Data is normally transmitted in 7 bit ASCII format This parameter allows the scanner to interface with devices requiring an 8 bit ASCII protocol 7 BIT ...

Page 115: ...5 51 Parameter Menus RS 232C Port Host Options ASCII Format 8 BIT ...

Page 116: ...00 Product Reference Guide RS 232C Port Host Options Serial Host RTS Line State This parameter is used to set the idle state of the Serial Host RTS line To select HIGH RTS line state scan the bar code below HOST HIGH RTS ...

Page 117: ...5 53 Parameter Menus RS 232C Port Host Options Serial Host RTS Line State HOST LOW RTS ...

Page 118: ... Host Options Beep on BEL When this parameter is enabled the scanner issues a beep when a BEL character is detected on the RS 232C serial line BEL is issued to gain a user s attention to indicate an illegal entry or other important event BEEP ON BEL CHARACTER ...

Page 119: ...5 55 Parameter Menus RS 232C Port Host Options Do Not Beep on BEL DO NOT BEEP ON BEL CHARACTER ...

Page 120: ...rminal to the Host port and an RS 232C device such as a portable terminal or scale to the RS 232C port 2 Use the programming bar codes on pages 5 57 to 5 84 to set the applicable RS 232C auxiliary parameters Connecting to two RS 232C devices Connect an RS 232C device to the Host port using a Synapse Smart Cable and another RS 232C device requiring different parameters baud rate parity etc to the R...

Page 121: ... second The scanner s baud rate setting should match the data rate setting of the host device If not data may not reach the host device or may reach it in distorted form To select a baud rate of 110 scan the bar code below To select other baud rates scan the corresponding bar code on the following pages BAUD RATE 110 ...

Page 122: ...5 58 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Baud Rate BAUD RATE 300 ...

Page 123: ...5 59 Parameter Menus RS 232C Port Auxiliary Options Baud Rate BAUD RATE 600 ...

Page 124: ...5 60 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Baud Rate BAUD RATE 1200 ...

Page 125: ...5 61 Parameter Menus RS 232C Port Auxiliary Options Baud Rate BAUD RATE 2400 ...

Page 126: ...5 62 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Baud Rate BAUD RATE 4800 ...

Page 127: ...5 63 Parameter Menus RS 232C Port Auxiliary Options Baud Rate BAUD RATE 9600 ...

Page 128: ...5 64 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Baud Rate BAUD RATE 19200 ...

Page 129: ...ptions Parity A parity check bit is the most significant bit of each ASCII coded character Odd If you select ODD parity the parity bit has a value 0 or 1 based on data to ensure than an odd number of 1 bits are contained in the coded character ODD ...

Page 130: ...Product Reference Guide RS 232C Port Auxiliary Options Parity Even If you select EVEN parity the parity bit has a value 0 or 1 based on data to ensure than an even number of 1 bits are contained in the coded character EVEN ...

Page 131: ...5 67 Parameter Menus RS 232C Port Auxiliary Options Parity Mark Select MARK parity and the parity bit is always 1 MARK ...

Page 132: ...5 68 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Parity Space Select SPACE parity and the parity bit is always 0 SPACE ...

Page 133: ...5 69 Parameter Menus RS 232C Port Auxiliary Options Parity None If no parity is required select NONE NONE ...

Page 134: ...800 Product Reference Guide RS 232C Port Auxiliary Options Check Parity Select whether or not the parity of received characters is checked The type of parity used is selectable through the PARITY parameter CHECK PARITY ...

Page 135: ...5 71 Parameter Menus RS 232C Port Auxiliary Options Do Not Check Parity DO NOT CHECK PARITY ...

Page 136: ...er waits up to 2 seconds for the host to negate the CTS line If after 2 seconds the CTS line is still asserted the scanner sounds a transmit error and any scanned data is lost When the CTS line is negated the controller asserts the RTS line and waits up to 2 seconds for the host to assert CTS When the host asserts CTS data is transmitted If after 2 seconds the CTS line is not asserted the scanner ...

Page 137: ...rted If CTS is de asserted for more than 50 msec between characters the transmission is aborted the scanner sounds a transmission error and the data is discarded If the above communications sequence fails the scanner issues an error indication In this case the data is lost and must be rescanned Note The DTR signal is jumpered active ...

Page 138: ...5 74 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Hardware Handshaking None Scan the bar code below if no Hardware Handshaking is desired NONE ...

Page 139: ...5 75 Parameter Menus RS 232C Port Auxiliary Options Hardware Handshaking Standard RTC CTS Scan the bar code below to select Standard RTS CTS Hardware Handshaking STANDARD RTS CTS ...

Page 140: ... 232C Port Auxiliary Options Software Handshaking This parameter offers control of the data transmission process in addition to or instead of that offered by hardware handshaking NONE When this option is selected data is transmitted immediately NONE ...

Page 141: ...n the scanner has data to send it then waits for an XON character before transmission The scanner waits up to 2 seconds to receive the XON If the XON is not received within this time the scanner issues an error indication and discards the data XOFF is received during a transmission Data transmission then stops after sending the current byte When the scanner receives an XON character it sends the r...

Page 142: ...parameter determines the maximum period allowed to elapse before the scanner assumes end of transmission The delay period can range from 0 0 to 9 9 seconds in 1 second increments After scanning the bar code below scan two bar codes on pages 5 246 to 5 255 to set the desired time out SERIAL RESPONSE TIME OUT ...

Page 143: ...r marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits one or two selected depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to match those device requirements 1 STOP BIT ...

Page 144: ...5 80 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options Stop Bit Select 2 STOP BITS ...

Page 145: ...rameter Menus RS 232C Port Auxiliary Options ASCII Format Data is normally transmitted in 7 bit ASCII format This parameter allows the scanner to interface with devices requiring an 8 bit ASCII protocol 7 BIT ...

Page 146: ...5 82 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options ASCII Format 8 BIT ...

Page 147: ...ameter Menus RS 232C Port Auxiliary Options RTS Line State This parameter is used to set the idle state of the Auxiliary Serial RTS line To select HIGH RTS line state scan the bar code below AUXILIARY HIGH RTS ...

Page 148: ...5 84 LS 5700 LS 5800 Product Reference Guide RS 232C Port Auxiliary Options RTS Line State AUXILIARY LOW RTS ...

Page 149: ...he LS 5700 LS 5800 primary scanner is not affected Any changes made to the decode parameters i e code types lengths or check digits are not recognized by the primary scanner However if any of these parameters on the primary scanner is changed the change overrides the hand held scanner setting This parameter does not apply to LS 2603MX LS 3603MX or LS 3203 scanners PROGRAM HAND HELD SCANNER ONLY ...

Page 150: ...imary scanner LS 5700 LS 5800 They do not affect the hand held laser scanner Any changes made to the decode parameters i e code types lengths or check digits are reflected back to the hand held scanner as well This mode is useful for programming the primary scanner using the hand held scanner This parameter does not apply to LS 2603MX LS 3603MX or LS 3203 scanners PROGRAM PRIMARY SCANNER ONLY ...

Page 151: ...ge the settings on the hand held laser scanner only The LS 5700 LS 5800 primary scanner is not affected Any changes made to the decode parameters i e code types lengths or check digits are not recognized by the primary scanner However if any of these parameters on the primary scanner is changed the change overrides the hand held scanner setting PROGRAM HAND HELD SCANNER ONLY ...

Page 152: ... bar codes scanned only change the settings on the primary scanner LS 5700 LS 5800 They do not affect the hand held laser scanner Any changes made to the decode parameters i e code types lengths or check digits are reflected back to the hand held scanner as well This mode is useful for programming the primary scanner using the hand held scanner PROGRAM PRIMARY SCANNER ONLY ...

Page 153: ...r bar codes scanned change the settings on the primary scanner LS 5700 LS 5800 and the hand held scanner If either scanner does not recognize a particular parameter bar code the parameter was not meant for that scanner that scanner emits an error beep The other scanner emits a warble tone PROGRAM ALL SCANNERS ...

Page 154: ...Reference Guide Hand Held Laser Scanner Options Beep After Good Decode This parameter affects the hand held scanner only When enabled the scanner plugged into the Scanner port beeps after a successful decode BEEP AFTER GOOD DECODE ...

Page 155: ...ter Good Decode This parameter affects the hand held scanner only When disabled the scanner plugged into the Scanner port does not beep after a successful decode Beeps for parameter menu scanning and serial communications are not affected DO NOT BEEP AFTER GOOD DECODE ...

Page 156: ...5 92 LS 5700 LS 5800 Product Reference Guide Code Types Options UPC A To enable UPC A scan the bar code below ENABLE UPC A ...

Page 157: ...5 93 Parameter Menus Code Types Options Disable UPC A To disable UPC A scan the bar code below DISABLE UPC A ...

Page 158: ...5 94 LS 5700 LS 5800 Product Reference Guide Code Types Options UPC E To enable UPC E scan the bar code below ENABLE UPC E ...

Page 159: ...5 95 Parameter Menus Code Types Options Disable UPC E To disable UPC E scan the bar code below DISABLE UPC E ...

Page 160: ...5 96 LS 5700 LS 5800 Product Reference Guide Code Types Options EAN 8 To enable EAN 8 scan the bar code below ENABLE EAN 8 ...

Page 161: ...5 97 Parameter Menus Code Types Options Disable EAN 8 To disable EAN 8 scan the bar code below DISABLE EAN 8 ...

Page 162: ...5 98 LS 5700 LS 5800 Product Reference Guide Code Types Options EAN 13 To enable EAN 13 scan the bar code below ENABLE EAN 13 ...

Page 163: ...5 99 Parameter Menus Code Types Options Disable EAN 13 To disable EAN 13 scan the bar code below DISABLE EAN 13 ...

Page 164: ...EAN 13 bar code containing a leading 978 prefix The symbol may contain a five digit supplemental The first digit is a currency code and the remaining four are a price digit code When scanning this code type enabling Autodiscriminate UPC EAN With Supplementals on page 5 104 is recommended ENABLE BOOKLAND EAN ...

Page 165: ...5 101 Parameter Menus Code Types Options Disable Bookland EAN To disable Bookland EAN scan the bar code below DISABLE BOOKLAND EAN ...

Page 166: ... e g UPC A 2 UPC E 2 EAN 8 2 Three options are available If UPC EAN with supplemental characters is selected UPC EAN symbols without supplemental characters are not decoded An autodiscriminate option is also available Note In order to minimize the risk of invalid data transmission it is recommended that you select whether to read or ignore supplemental characters DECODE UPC EAN WITH SUPPLEMENTALS ...

Page 167: ...available If UPC EAN without supplemental characters is selected and the scanner is presented with a UPC EAN plus supplemental symbol the UPC EAN are decoded and the supplemental characters ignored An autodiscriminate option is also available Note In order to minimize the risk of invalid data transmission it is recommended that you select whether to read or ignore supplemental characters DECODE UP...

Page 168: ...e Types Options Autodiscriminate UPC EAN With Supplementals Note In order to minimize the risk of invalid data transmission it is recommended that you select whether to read or ignore supplemental characters AUTODISCRIMINATE UPC EAN WITH SUPPLEMENTALS ...

Page 169: ... this parameter decodes UPC A UPC A with 2 supplemental characters UPC A with 5 supplemental characters and UPC A EAN 128 bar codes To enable this code type 1 Scan the bar code below 2 Scan AUTODISCRIMINATE UPC EAN WITH SUPPLEMENTALS on page 5 104 ENABLE UPC EAN COUPON CODE ...

Page 170: ...5 106 LS 5700 LS 5800 Product Reference Guide Code Types Options Disable UCC EAN Coupon Code DISABLE UPC EAN COUPON CODE ...

Page 171: ...or 5 digit random weight check digit may be embedded in a UPC A or EAN 13 bar code for added price verification To enable either of these options or to disable this parameter entirely scan the appropriate bar code below or on the following pages DISABLE RANDOM WEIGHT CHECK DIGIT ...

Page 172: ...5 108 LS 5700 LS 5800 Product Reference Guide Code Types Options Random Weight Check Digit ENABLE 4 DIGIT RANDOM WEIGHT CHECK DIGIT ...

Page 173: ...5 109 Parameter Menus Code Types Options Random Weight Check Digit ENABLE 5 DIGIT RANDOM WEIGHT CHECK DIGIT ...

Page 174: ...5 110 LS 5700 LS 5800 Product Reference Guide Code Types Options Code 128 To enable Code 128 scan the bar code below ENABLE CODE 128 ...

Page 175: ...5 111 Parameter Menus Code Types Options Disable Code 128 To disable Code 128 scan the bar code below DISABLE CODE 128 ...

Page 176: ...5 112 LS 5700 LS 5800 Product Reference Guide Code Types Options UCC EAN 128 To enable UCC EAN 128 scan the bar code below ENABLE UCC EAN 128 ...

Page 177: ...5 113 Parameter Menus Code Types Options Disable UCC EAN 128 To disable UCC EAN 128 scan the bar code below DISABLE UCC EAN 128 ...

Page 178: ...5 114 LS 5700 LS 5800 Product Reference Guide Code Types Options Lengths for Code 128 No length setting is required for Code 128 The default setting is Any Length ...

Page 179: ...5 115 Parameter Menus Code Types Options Code 39 To enable Code 39 scan the bar code below ENABLE CODE 39 ...

Page 180: ...5 116 LS 5700 LS 5800 Product Reference Guide Code Types Options Disable Code 39 To disable Code 39 scan the bar code below DISABLE CODE 39 ...

Page 181: ... BACKSPACE and RETURN The other 96 are called printable codes because all but SPACE and DELETE produce visible characters Code 39 Full ASCII interprets the bar code special character preceding a Code 39 character and assigns an ASCII character value to the pair For example when Code 39 Full ASCII is enabled and a B is scanned it is interpreted as b J as and H emulates the keystroke BACKSPACE Scann...

Page 182: ...5 118 LS 5700 LS 5800 Product Reference Guide Code Types Options Enable Code 39 Full ASCII ENABLE CODE 39 FULL ASCII ...

Page 183: ...5 119 Parameter Menus Code Types Options Disable Code 39 Full ASCII DISABLE CODE 39 FULL ASCII ...

Page 184: ...rs to the number of characters i e human readable characters the code contains One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select Code 39 One Discrete Length then scan 1 4 only Code 39 symbols containing 14 characters are decoded Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 CO...

Page 185: ...ng two selected lengths For example if you select Code 39 Two Discrete Lengths then scan 0 2 1 4 only Code 39 symbols containing 2 or 14 characters are decoded Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 Note Selecting this option disables Code 39 Decode Performance CODE 39 TWO DISCRETE LENGTHS ...

Page 186: ...r example to decode Code 39 symbols containing between 4 and 12 characters first scan Code 39 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 Note Selecting this option disables Code 39 Decode Performance CODE 39 LENGTH WITHIN RANGE ...

Page 187: ...e Types Options Set Lengths for Code 39 Any Length Scanning this option allows you to decode Code 39 symbols containing any number of characters Note Selecting this option disables Code 39 Decode Performance CODE 39 ANY LENGTH ...

Page 188: ...heck Digit Verification When enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled ENABLE CODE 39 CHECK DIGIT ...

Page 189: ...5 125 Parameter Menus Code Types Options Disable Code 39 Check Digit DISABLE CODE 39 CHECK DIGIT ...

Page 190: ...5 126 LS 5700 LS 5800 Product Reference Guide Code Types Options Interleaved 2 of 5 To enable Interleaved 2 of 5 scan the bar code below ENABLE I 2 OF 5 ...

Page 191: ...5 127 Parameter Menus Code Types Options Disable I 2 of 5 DISABLE I 2 OF 5 ...

Page 192: ...refers to the number of characters i e human readable characters the code contains One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select I 2 of 5 One Discrete Length then scan 1 4 only I 2 of 5 symbols containing 14 characters are decoded Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 ...

Page 193: ... to decode only those codes containing two selected lengths For example if you select I 2 of 5 Two Discrete Lengths then scan 0 2 1 4 only I 2 of 5 symbols containing 2 or 14 characters are decoded Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 I 2 of 5 TWO DISCRETE LENGTHS ...

Page 194: ...de type within a specified range For example to decode I 2 of 5 symbols containing between 4 and 12 characters first scan I 2 of 5 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 I 2 of 5 LENGTH WITHIN RANGE ...

Page 195: ...5 131 Parameter Menus Code Types Options Set Lengths for Interleaved 2 of 5 Any Length Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters I 2 of 5 ANY LENGTH ...

Page 196: ...ptions I 2 of 5 Check Digit Verification USS When enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm either USS Uniform Symbology Specification or OPCC Optical Product Code Council USS CHECK DIGIT ...

Page 197: ...5 133 Parameter Menus Code Types Options OPCC Check Digit Verification OPCC OPCC CHECK DIGIT ...

Page 198: ...5 134 LS 5700 LS 5800 Product Reference Guide Code Types Options I 2 of 5 Check Digit Verification DISABLE I 2 OF 5 CHECK DIGIT VERIFICATION ...

Page 199: ...5 135 Parameter Menus Code Types Options Codabar To enable Codabar scan the bar code below ENABLE CODABAR ...

Page 200: ...5 136 LS 5700 LS 5800 Product Reference Guide Code Types Options Disable Codabar To disable Codabar scan the symbol below DISABLE CODABAR ...

Page 201: ... readable characters the code contains One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select Codabar One Discrete Length then scan 1 4 only Codabar symbols containing 14 characters are decoded Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 Note Codabar lengths include start and sto...

Page 202: ...lows you to decode only those codes containing two selected lengths For example if you select Codabar Two Discrete Lengths then scan 0 2 1 4 only Codabar symbols containing 2 or 14 characters are decoded Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 CODABAR TWO DISCRETE LENGTHS ...

Page 203: ... specified range For example to decode Codabar symbols containing between 4 and 12 characters first scan Codabar Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan CANCEL on page 5 256 CODABAR LENGTH WITHIN RANGE ...

Page 204: ... LS 5700 LS 5800 Product Reference Guide Code Types Options Set Lengths for Codabar Any Length Scanning this option allows you to decode Codabar symbols containing any number of characters CODABAR ANY LENGTH ...

Page 205: ...ting If enabled this parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Note that symbol length does not include start and stop characters ENABLE CLSI EDITING ...

Page 206: ...5 142 LS 5700 LS 5800 Product Reference Guide Code Types Options Disable CLSI Editing DISABLE CLSI EDITING ...

Page 207: ...5 143 Parameter Menus Code Types Options NOTIS Editing If enabled this parameter strips the start and stop characters from decoded Codabar symbol ENABLE NOTIS EDITING ...

Page 208: ...5 144 LS 5700 LS 5800 Product Reference Guide Code Types Options Disable NOTIS Editing DISABLE NOTIS EDITING ...

Page 209: ...ode range that best suits your scanning needs FULL RANGE covers the maximum scanning range and is recommended for in counter applications and installations where there is no opportunity for inadvertent reads Decode range data is shown in Table 4 2 on page 4 5 FULL RANGE ...

Page 210: ...Reference Guide Custom Tailoring Scanning Range MEDIUM RANGE is recommended for on counter applications and installations where full range may allow inadvertent reads Decode range data is shown in Table 4 2 on page 4 5 MEDIUM RANGE ...

Page 211: ...47 Parameter Menus Custom Tailoring Scanning Range SHORT RANGE is recommended for on counter applications where counter space is at a minimum Decode range data is shown in Table 4 2 on page 4 5 SHORT RANGE ...

Page 212: ...5 148 LS 5700 LS 5800 Product Reference Guide Custom Tailoring Internal Beeper This parameter connects the beeper signal to the internal beeper ENABLE INTERNAL BEEPER ...

Page 213: ...5 149 Parameter Menus Custom Tailoring Disable Internal Beeper This parameter disconnects the beeper signal to the internal beeper DISABLE INTERNAL BEEPER ...

Page 214: ...5 150 LS 5700 LS 5800 Product Reference Guide Custom Tailoring RS 232C Port External Beeper This parameter connects the beeper signal to the RS 232C Port ENABLE RS 232C PORT EXTERNAL BEEPER ...

Page 215: ...5 151 Parameter Menus Custom Tailoring Disable RS 232C Port External Beeper This parameter disconnects the beeper signal to the RS 232C Port DISABLE RS 232C PORT EXTERNAL BEEPER ...

Page 216: ...5 152 LS 5700 LS 5800 Product Reference Guide Custom Tailoring Beeper Volume Select the beeper volume that best suits your operation LOW VOLUME ...

Page 217: ...5 153 Parameter Menus Custom Tailoring Beeper Volume MEDIUM VOLUME ...

Page 218: ...5 154 LS 5700 LS 5800 Product Reference Guide Custom Tailoring Beeper Volume HIGH VOLUME ...

Page 219: ...5 155 Parameter Menus Custom Tailoring Beeper Frequency To select a decode beep frequency tone scan the LOW FREQUENCY MEDIUM FREQUENCY or HIGH FREQUENCY bar code LOW FREQUENCY ...

Page 220: ...5 156 LS 5700 LS 5800 Product Reference Guide Custom Tailoring Beeper Frequency MEDIUM FREQUENCY ...

Page 221: ...5 157 Parameter Menus Custom Tailoring Beeper Frequency HIGH FREQUENCY ...

Page 222: ...rogrammable in 0 1 second increments from 0 0 to 9 9 seconds Setting this above 0 4 seconds is recommended Scan the bar code below to select a new time out Next scan two numeric bar codes on pages 5 246 to 5 255 the first representing seconds the second tenths of seconds If you make an error or wish to change your selection scan CANCEL on page 5 256 TIME OUT BETWEEN SAME SYMBOL ...

Page 223: ...bols It is programmable in 0 1 second increments from 0 0 to 9 9 seconds Scan the bar code below to select a new time out Next scan two numeric bar codes on pages 5 246 to 5 255 the first representing seconds the second tenths of seconds If you make an error or wish to change your selection scan CANCEL on page 5 256 TIME OUT BETWEEN DIFFERENT SYMBOLS ...

Page 224: ...Product Reference Guide Custom Tailoring Decode Buffering When enabled successive decodes are buffered by the scanner This is useful when the host takes a long time to receive and or process a symbol ENABLE DECODE BUFFERING ...

Page 225: ...oring Disable Decode Buffering When disabled successive decodes are no longer buffered by the scanner The scanner waits until a decoded symbol is transmitted to the host device before processing another symbol DISABLE DECODE BUFFERING ...

Page 226: ...g Rest Mode To choose a Rest Mode for the LS 5700 LS 5800 scan the bar code below The default time is 30 minutes That is 30 minutes after a scan attempt the scanner enters this mode To change the time to rest mode scan a bar code beginning on page 5 164 REST MODE ...

Page 227: ...p Mode The LS 5700 can be programmed to completely shut down The default time is 30 minutes That is 30 minutes after a scan attempt the scanner enters this mode To change the time to sleep mode scan a bar code beginning on page 5 164 SLEEP MODE ...

Page 228: ...e This parameter sets the time the scanner remains active after any scanning activity Scan one of the four options Depending on the selection the scanner enters a rest sleep mode 15 30 60 or 90 minutes after the last attempted decode If you make a mistake scan CANCEL on page 5 256 15 MINUTES ...

Page 229: ...5 165 Parameter Menus Custom Tailoring Time Delay to Rest Sleep Mode 30 MINUTES ...

Page 230: ...5 166 LS 5700 LS 5800 Product Reference Guide Custom Tailoring Time Delay to Rest Sleep Mode 60 MINUTES ...

Page 231: ...5 167 Parameter Menus Custom Tailoring Time Delay to Rest Sleep Mode 90 MINUTES ...

Page 232: ...programmable in 0 1 second increments from 0 1 to 9 9 seconds Setting this between 1 0 and 3 0 seconds is recommended Scan the bar code below to select a new time out Next scan two numeric bar codes on pages 5 246 to 5 255 the first representing seconds the second tenths of seconds If you make an error or wish to change your selection scan CANCEL on page 5 256 DECODE ATTEMPT DURATION ...

Page 233: ... representing left and right halves For example bar code1234567890 is divided into left block 12345 and right block 67890 To maximize its aggressiveness the scanner is capable of decoding a UPC EAN symbol by splicing together a left block read by one of the 20 scan lines and a right block read by another ...

Page 234: ... completely exited the scanner s field of view with a block from a new symbol that has just been presented to the scanner This option requires the scanner to compare the new symbol against the symbol just decoded to see if there are common blocks If either the left or right blocks match between symbols the scanner rejects the common block for the period of time dictated by the TIME OUT BETWEEN DEC...

Page 235: ...Parameter Menus Decode Options Accept Predecode Block This option allows immediate decode of a new UPC EAN bar code regardless of the previously decoded UPC EAN bar code s block content ACCEPT PREDECODE BLOCK ...

Page 236: ...ed for decreasing levels of bar code quality There is an inverse relationship between security and scanner aggressiveness so be sure to choose only that level of security necessary for any given application Level 0 This is the default setting which allows the scanner to operate in its most aggressive state while providing sufficient security in decoding in spec UPC EAN bar codes UPC EAN SECURITY L...

Page 237: ...bar code quality levels diminish certain characters become prone to mis decodes before others i e 1 2 7 8 If you are experiencing mis decodes of poorly printed bar codes and the mis decodes are limited to these characters select this security level UPC EAN SECURITY LEVEL 1 ...

Page 238: ...rence Guide Decode Options UPC EAN Security Level Level 2 If you are experiencing mis decodes of poorly printed bar codes and the mis decodes are not limited to characters 1 2 7 and 8 select this security level UPC EAN SECURITY LEVEL 2 ...

Page 239: ...des select this security level Be advised selecting this option is an extreme measure against mis decoding severely out of spec bar codes Selection of this level significantly impairs the decoding ability of the scanner If this level of security is necessary you should try to improve the quality of your bar codes UPC EAN SECURITY LEVEL 3 ...

Page 240: ...es to code types containing two adjacent blocks e g UPC A EAN 8 EAN 13 When enabled a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan This option should be enabled when bar codes are in proximity to each other ENABLE LINEAR UPC EAN DECODE ...

Page 241: ...5 177 Parameter Menus Decode Options Disable Linear UPC EAN Decode DISABLE LINEAR UPC EAN DECODE ...

Page 242: ...ode types containing two or five character supplementals When enabled a bar code is transmitted only when both the supplemental block and its adjacent block are successfully decoded within one laser scan This option should be enabled when bar codes are in proximity to each other ENABLE LINEAR SUPPLEMENTAL DECODE ...

Page 243: ...5 179 Parameter Menus Decode Options Disable Linear Supplemental Decode DISABLE LINEAR SUPPLEMENTAL DECODE ...

Page 244: ...n The range is from two to thirty times Ten or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals Scan the bar code below to select a decode redundancy value Next scan two numeric bar codes on pages 5 246 to 5 255 that represent the desired number of times For single digit numbers include a leading zero If you make an error or wish to change your selection s...

Page 245: ...pplementals Increasing the performance level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enable this option you may select a Decode Performance level from the following pages to suit your performance needs ENABLE UPC EAN DECODE PERFORMANCE ...

Page 246: ...5 182 LS 5700 LS 5800 Product Reference Guide Decode Options Disable UPC EAN Decode Performance DISABLE UPC EAN DECODE PERFORMANCE ...

Page 247: ...5 183 Parameter Menus Decode Options UPC EAN Decode Performance Level 1 UPC EAN DECODE PERFORMANCE LEVEL 1 ...

Page 248: ...5 184 LS 5700 LS 5800 Product Reference Guide Decode Options UPC EAN Decode Performance Level 2 UPC EAN DECODE PERFORMANCE LEVEL 2 ...

Page 249: ...5 185 Parameter Menus Decode Options UPC EAN Decode Performance Level 3 UPC EAN DECODE PERFORMANCE LEVEL 3 ...

Page 250: ...ers four levels of decode security for linear code types e g Code 39 Interleaved 2 of 5 Higher security levels are selected for decreasing levels of bar code quality As security levels increase the scanner s aggressiveness decreases Select the security level appropriate for your bar code quality LINEAR SECURITY LEVEL 1 ...

Page 251: ...5 187 Parameter Menus Decode Options Linear Code Type Security Level 2 LINEAR SECURITY LEVEL 2 ...

Page 252: ...5 188 LS 5700 LS 5800 Product Reference Guide Decode Options Linear Code Type Security Level 3 LINEAR SECURITY LEVEL 3 ...

Page 253: ...5 189 Parameter Menus Decode Options Linear Code Type Security Level 4 LINEAR SECURITY LEVEL 4 ...

Page 254: ...e 128 symbols Increasing the performance level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enable this option you may select a Decode Performance level from the following pages to suit your performance needs ENABLE CODE 128 DECODE PERFORMANCE ...

Page 255: ...5 191 Parameter Menus Decode Options Disable Code 128 Decode Performance DISABLE CODE 128 DECODE PERFORMANCE ...

Page 256: ...5 192 LS 5700 LS 5800 Product Reference Guide Decode Options Code 128 Decode Performance Level 1 CODE 128 DECODE PERFORMANCE LEVEL 1 ...

Page 257: ...5 193 Parameter Menus Decode Options Code 128 Decode Performance Level 2 CODE 128 DECODE PERFORMANCE LEVEL 2 ...

Page 258: ...5 194 LS 5700 LS 5800 Product Reference Guide Decode Options Code 128 Decode Performance Level 3 CODE 128 DECODE PERFORMANCE LEVEL 3 ...

Page 259: ...vel reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enable this option you may select a Decode Performance level from the following pages to suit your performance needs Note This option only works with Code 39 One Discrete Length ENABLE CODE 39 DECODE PERFORMANCE ...

Page 260: ...5 196 LS 5700 LS 5800 Product Reference Guide Decode Options Disable Code 39 Decode Performance DISABLE CODE 39 DECODE PERFORMANCE ...

Page 261: ...5 197 Parameter Menus Decode Options Code 39 Decode Performance Level 1 CODE 39 DECODE PERFORMANCE LEVEL 1 ...

Page 262: ...5 198 LS 5700 LS 5800 Product Reference Guide Decode Options Code 39 Decode Performance Level 2 CODE 39 DECODE PERFORMANCE LEVEL 2 ...

Page 263: ...5 199 Parameter Menus Decode Options Code 39 Decode Performance Level 3 CODE 39 DECODE PERFORMANCE LEVEL 3 ...

Page 264: ...5 200 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Transmit UPC A Check Digit Scan this bar code to transmit the symbol with the UPC A check digit TRANSMIT UPC A CHECK DIGIT ...

Page 265: ...5 201 Parameter Menus Data Transmission Formats Do Not Transmit UPC A Check Digit Scan this bar code to transmit the symbol without the UPC A check digit DO NOT TRANSMIT UPC A CHECK DIGIT ...

Page 266: ...5 202 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Transmit UPC E Check Digit Scan this bar code to transmit the symbol with the UPC E check digit TRANSMIT UPC E CHECK DIGIT ...

Page 267: ...5 203 Parameter Menus Data Transmission Formats Do Not Transmit UPC E Check Digit Scan this bar code to transmit the symbol without the UPC E check digit DO NOT TRANSMIT UPC E CHECK DIGIT ...

Page 268: ...ble Three options are given for lead in characters for UPC A symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol NO PREAMBLE DATA ...

Page 269: ...5 205 Parameter Menus Data Transmission Formats UPC A Preamble Scan this bar code if you want to transmit the symbol with the System Character SYSTEM CHARACTER SYSTEM CHARACTER DATA ...

Page 270: ...roduct Reference Guide Data Transmission Formats UPC A Preamble Scan this bar code if you want to transmit the symbol with the System Character and Country Code SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA ...

Page 271: ...tions are given for lead in characters for UPC E symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol NO PREAMBLE DATA ...

Page 272: ...208 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats UPC E Preamble Scan this bar code if you want to transmit the symbol with the System Character SYSTEM CHARACTER SYSTEM CHARACTER DATA ...

Page 273: ...eter Menus Data Transmission Formats UPC E Preamble Scan this bar code if you want to transmit the symbol with the System Character and Country Code SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA ...

Page 274: ... Formats Convert UPC E to UPC A This parameter converts UPC E zero suppressed decoded data to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit CONVERT UPC E TO UPC A ...

Page 275: ... 211 Parameter Menus Data Transmission Formats Do Not Convert UPC E to UPC A Scanning DO NOT CONVERT UPC E TO UPC A allows you to transmit UPC E zero suppressed decoded data DO NOT CONVERT UPC E TO UPC A ...

Page 276: ...Product Reference Guide Data Transmission Formats EAN Zero Extend If this parameter is enabled five leading zeros are added to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols ENABLE EAN ZERO EXTEND ...

Page 277: ...5 213 Parameter Menus Data Transmission Formats Disable EAN Zero Extend Disabling this parameter returns EAN 8 symbols to their normal format DISABLE EAN EXTEND ...

Page 278: ... Convert EAN 8 to EAN 13 Type When EAN Zero Extend is enabled this parameter gives you the option of labeling the extended symbol as either an EAN 13 bar code or an EAN 8 bar code When EAN Zero Extend is disabled this parameter has no effect on bar code data TYPE IS EAN 13 ...

Page 279: ... EAN 8 to EAN 13 Type When EAN Zero Extend is enabled this parameter gives you the option of labeling the extended symbol as either an EAN 13 bar code or an EAN 8 bar code When EAN Zero Extend is disabled this parameter has no effect on bar code data TYPE IS EAN 8 ...

Page 280: ...13 This parameter converts a 14 character I 2 of 5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled one length must be set to 14 and the code must have a leading zero and a valid EAN 13 check digit CONVERT I 2 of 5 to EAN 13 ENABLE ...

Page 281: ...5 217 Parameter Menus Data Transmission Formats Do Not Convert I 2 of 5 to EAN 13 DO NOT CONVERT I 2 of 5 to EAN 13 DISABLE ...

Page 282: ...8 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Transmit I 2 of 5 Check Digit Scan this symbol if you want to transmit the check digit with the data TRANSMIT I 2 of 5 CHECK DIGIT ENABLE ...

Page 283: ... 219 Parameter Menus Data Transmission Formats Do Not Transmit I 2 of 5 Check Digit Scan this symbol if you want to transmit the data without the check digit DO NOT TRANSMIT I 2 of 5 CHECK DIGIT DISABLE ...

Page 284: ...20 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Transmit Code 39 Check Digit Scan this symbol if you want to transmit the check digit with the data TRANSMIT CODE 39 CHECK DIGIT ENABLE ...

Page 285: ...5 221 Parameter Menus Data Transmission Formats Do Not Transmit Code 39 Check Digit Scan this symbol if you want to transmit the data without the check digit DO NOT TRANSMIT CODE 39 CHECK DIGIT DISABLE ...

Page 286: ...5 222 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Beep After Good Decode Scan this symbol if you want the unit to beep after a good decode BEEP AFTER GOOD DECODE ...

Page 287: ...mission Formats Do Not Beep After Good Decode Scan this symbol if you want the unit not to beep after a good decode The beeper still operates during parameter menu scanning and indicates error conditions DO NOT BEEP AFTER GOOD DECODE ...

Page 288: ...ing host requirements The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters The delay period can range from no delay to 99 msec in 1 msec increments After scanning the bar code below scan two bar codes on pages 5 246 to 5 255 to set the desired time out INTERCHARACTER DELAY ...

Page 289: ...prefix already selected the code ID character is inserted between the prefix and the decoded symbol The user may select no code ID character a Symbol Code ID character or an AIM Code ID character The Symbol Code ID characters are listed below see Table A 2 in the Appendix for AIM Identifiers A UPC A UPC E EAN 8 or EAN 13 B Code 39 C Codabar D Code 128 F Interleaved 2 of 5 K UCC EAN 128 L Bookland ...

Page 290: ...5 226 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Transmit AIM Code ID Character TRANSMIT AIM CODE ID CHARACTER ...

Page 291: ...5 227 Parameter Menus Data Transmission Formats Do Not Transmit AIM or Symbol ID Character DO NOT TRANSMIT AIM OR SYMBOL CODE ID CHARACTERS ...

Page 292: ...data transmission Pauses are set by scanning a two digit number i e two bar codes and are measured in 1 10 second intervals For example scanning bar codes 0 and 1 inserts a 1 10 second pause 0 and 5 gives you a 1 2 second delay Numeric bar codes are found on pages 5 246 to 5 255 If you make a mistake scan DATA FORMAT CANCEL on page 5 245 PAUSE DURATION ...

Page 293: ...use in data editing These values are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table A 4 in the Appendix Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan the DATA FORMAT CANCEL bar code on page 5 245 and start over SCAN PREFIX ...

Page 294: ...5 230 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Prefix Suffix Values SCAN SUFFIX ...

Page 295: ...5 231 Parameter Menus Data Transmission Formats Prefix Suffix Values SERIAL PREFIX ...

Page 296: ...5 232 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Prefix Suffix Values SERIAL SUFFIX ...

Page 297: ...for use in data editing These values are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table A 4 in the Appendix Numeric bar codes are on pages 5 246 to 5 255 If you make a mistake scan the DATA FORMAT CANCEL bar code on page 5 245 and start over SCAN OPTIONS ...

Page 298: ...5 234 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Scan Data Transmission Format DATA AS IS ...

Page 299: ...5 235 Parameter Menus Data Transmission Formats Scan Data Transmission Format DATA CR 1013 ...

Page 300: ...5 236 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Scan Data Transmission Format PREFIX DATA ...

Page 301: ...5 237 Parameter Menus Data Transmission Formats Scan Data Transmission Format PREFIX DATA SUFFIX ...

Page 302: ...5 238 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Serial Data Transmission Format SERIAL OPTIONS ...

Page 303: ...5 239 Parameter Menus Data Transmission Formats Serial Data Transmission Format DATA AS IS ...

Page 304: ...5 240 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Serial Data Transmission Format DATA SUFFIX ...

Page 305: ...5 241 Parameter Menus Data Transmission Formats Serial Data Transmission Format PREFIX DATA ...

Page 306: ...5 242 LS 5700 LS 5800 Product Reference Guide Data Transmission Formats Serial Data Transmission Format PREFIX DATA SUFFIX ...

Page 307: ...n Formats Ignore Unknown Characters When enabled all data is sent except for unknown characters and no error beeps are sounded Unknown characters are those characters the selected terminal does not recognize ENABLE IGNORE UNKNOWN CHARACTERS ...

Page 308: ...a Transmission Formats Disable Ignore Unknown Characters When disabled bar codes with unknown characters are decoded but not transmitted to the host A decode beep is followed by a communications error beep indication DISABLE IGNORE UNKNOWN CHARACTERS ...

Page 309: ...ameter Menus Data Transmission Formats Data Format Cancel If you make an error while entering scan or serial data transmission formats or wish to change your selection scan the bar code below DATA FORMAT CANCEL ...

Page 310: ...5 246 LS 5700 LS 5800 Product Reference Guide Programming Utilities Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 ...

Page 311: ...5 247 Parameter Menus Programming Utilities Numeric Bar Codes 1 ...

Page 312: ...5 248 LS 5700 LS 5800 Product Reference Guide Programming Utilities Numeric Bar Codes 2 ...

Page 313: ...5 249 Parameter Menus Programming Utilities Numeric Bar Codes 3 ...

Page 314: ...5 250 LS 5700 LS 5800 Product Reference Guide Programming Utilities Numeric Bar Codes 4 ...

Page 315: ...5 251 Parameter Menus Programming Utilities Numeric Bar Codes 5 ...

Page 316: ...5 252 LS 5700 LS 5800 Product Reference Guide Programming Utilities Numeric Bar Codes 6 ...

Page 317: ...5 253 Parameter Menus Programming Utilities Numeric Bar Codes 7 ...

Page 318: ...5 254 LS 5700 LS 5800 Product Reference Guide Programming Utilities Numeric Bar Codes 8 ...

Page 319: ...5 255 Parameter Menus Programming Utilities Numeric Bar Codes 9 ...

Page 320: ...5 256 LS 5700 LS 5800 Product Reference Guide Programming Utilities Cancel If you make an error or wish to change your selection scan CANCEL below CANCEL ...

Page 321: ...5 257 Parameter Menus Programming Utilities Enter When an ENTER is required such as for DATA TRANSMISSION FORMATS scan the bar code below ENTER ...

Page 322: ...5 258 LS 5700 LS 5800 Product Reference Guide Programming Utilities Applications Items Reserved for future use APPLICATIONS ITEM 1 ENABLE ...

Page 323: ...5 259 Parameter Menus Programming Utilities Applications Items Reserved for future use APPLICATIONS ITEM 1 DISABLE ...

Page 324: ...5 260 LS 5700 LS 5800 Product Reference Guide Programming Utilities Applications Items Reserved for future use APPLICATIONS ITEM 2 ENABLE ...

Page 325: ...5 261 Parameter Menus Programming Utilities Applications Items Reserved for future use APPLICATIONS ITEM 2 DISABLE ...

Page 326: ...5 262 LS 5700 LS 5800 Product Reference Guide Programming Utilities Applications Items Reserved for future use APPLICATIONS ITEM 3 ENABLE ...

Page 327: ...5 263 Parameter Menus Programming Utilities Applications Items Reserved for future use APPLICATIONS ITEM 3 DISABLE ...

Page 328: ...5 264 LS 5700 LS 5800 Product Reference Guide Programming Utilities Applications Items Reserved for future use Enter a 3 digit value from 0 to 255 APPLICATIONS VALUE ...

Page 329: ...racters with the ASCII 29 GS control character When AIM symbology identifiers are transmitted the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines Standard Code 128 bar codes which do not have a leading FNC 1 may still be used but will not be encoded according to the EAN 128 convention Standard Code 128 and UCC EAN 128 may be mixed in an applicat...

Page 330: ...NC1FNC1 ABCDFNC1 E are read as ABCD29 E ABCDFNC1 E cannot be read ABCDE cannot be read Enable Disable Read only symbols without leading FNC 1 Examples FNC1 ABCDFNC1 E cannot be read AFNC1 BCDFNC1 E cannot be read FNC1FNC1 ABCDFNC1 E cannot be read ABCDFNC1 E is read as ABCD29 E ABCDE is read as ABCDE Enable Enable Read both types of symbols Examples FNC1ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E ...

Page 331: ...ontains the three character string cm where Flag Character ASCII 93 c Code Character see Table A 2 m Modifier Character see Table A 3 Table A 2 Code Characters Code Character Code Type A Code 39 C Code 128 E UPC EAN F Codabar I Interleaved 2 of 5 X Bookland EAN ...

Page 332: ...I processing 1 Reader has checked one check character 3 Reader has checked and stripped check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Full ASCII character conversion and checked one check character 7 Reader has performed Full ASCII character conversion and checked and stripped check character Example A Full ASCII bar code with check character W A I M...

Page 333: ...s transmitted as C1AimId I 2 of 5 0 No check digit processing 1 Reader has validated check digit 3 Reader has validated and stripped check digit Example An I 2 of 5 bar code without check digit 4123 is transmitted as I04123 Codabar 0 No check digit processing 1 Reader has checked check digit 3 Reader has stripped check digit before transmission Example A Codabar bar code without check digit 4123 i...

Page 334: ...01234567890510 is transmitted to the host as a 21 character string E00012345678905 E110 UPC EAN 0 Standard packet in full EAN country code format which is 13 digits for UPC A and UPC E not including supplemental data 1 Two digit supplement data only 2 Five digit supplement data only 4 EAN 8 data packet Example A UPC A bar code 012345678905 is transmitted as E00012345678905 Bookland EAN 0 No option...

Page 335: ...kes Table A 4 ASCII Character Set ASCII Value Full ASCII Code 39 Encode Char Keystroke 1000 U CTRL 2 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H 1009 I CTRL I 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M 1014 N CTRL N 1015 O CTRL O 1016 P CTRL P 1017 Q CTRL Q 1018 R CTRL R 1019 S CTRL S 1020 T CTRL T 1021 U CTRL U ...

Page 336: ... X CTRL X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 1048 0 0 ASCII Value Full ASCII Code 39 Encode Char Keystroke ...

Page 337: ... 4 1053 5 5 1054 6 6 1057 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K ASCII Value Full ASCII Code 39 Encode Char Keystroke ...

Page 338: ...078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f ASCII Value Full ASCII Code 39 Encode Char Keystroke ...

Page 339: ...6 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1127 Undefined ASCII Value Full ASCII Code 39 Encode Char Keystroke ...

Page 340: ...3008 CMD 6 2072 ALT H 3009 CMD 7 2073 ALT I 3010 CMD 8 2074 ALT J 3011 CMD 9 2075 ALT K 3012 CMD 10 2076 ALT L 3013 2077 ALT M 3014 2078 ALT N 3015 2079 ALT O 3016 2080 ALT P 3017 2081 ALT Q 3018 1 2 2082 ALT R 3019 2083 ALT S 3020 2084 ALT T 3021 2085 ALT U 3022 0 00 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y PF Keys Keystroke 2090 ALT Z 4001 PF 1 2091 ALT 4002 PF 2 2092 ALT 4003 PF 3 2093 ALT 4...

Page 341: ...F 15 5018 F 18 4016 PF 16 5019 F 19 4017 PF 17 5020 F 20 4018 PF 18 5021 F 21 4019 PF 19 5022 F 22 4020 PF 20 5023 F 23 4021 PF 21 5024 F 24 4022 PF 22 5025 F 25 4023 PF 23 5026 F 26 4024 PF 24 5027 F 27 5028 F 28 5029 F 29 F Keys Keystroke 5030 F 30 5001 F 1 5031 F 31 5002 F 2 5032 F 32 5003 F 3 5033 F 33 5004 F 4 5034 F 34 5005 F 5 5035 F 35 5006 F 6 5036 F 36 5007 F 7 5037 F 37 5008 F 8 5038 F ...

Page 342: ...ned 7003 Pg Up 6045 7004 End 6046 7005 Pg Dn 6047 7006 Pause 6048 0 7007 Scroll Lock 6049 1 7008 Backspace 6050 2 7009 Tab 6051 3 7010 Prnt Screen 6052 4 7011 Insert 6053 5 7012 Home 6054 6 7013 Enter 6055 7 7014 Escape 6056 8 7015 Up Arrow 6057 9 7016 Dn Arrow 6058 Enter 7017 Left Arrow 6059 Num Lock 7018 Right Arrow 6060 00 7019 Back Tab ...

Page 343: ...20 beeper definitions 4 8 bullets ix C code types options 3 5 5 92 Bookland EAN 5 100 codabar 5 135 code 128 5 110 code 39 5 115 code 39 check digit verification 5 124 code 39 full ASCII 5 117 EAN 13 5 98 EAN 8 5 96 interleaved 2 of 5 5 126 interleaved 2 of 5 check digit verification OPCC 5 133 USS 5 132 lengths CLSI editing 5 141 codabar 5 137 ...

Page 344: ...ort 5B RS 232C 2 5 Port 9E Port 17 2 4 RS 232C host 2 6 synapse host 2 5 connectors 2 22 controls 2 20 conventions notational ix custom tailoring 3 5 5 145 5 168 beeper frequency 5 155 beeper volume 5 152 decode buffering 5 160 internal beeper 5 148 primary decode session time 5 168 rest mode 5 162 RS 232C port external beeper 5 150 scanning range 5 145 sleep mode 5 163 time delay to rest sleep mo...

Page 345: ...rial data transmission format 5 238 transmit code 39 check digit 5 220 transmit code ID character 5 225 transmit I 2 of 5 check digit 5 218 transmit UPC A check digit 5 200 transmit UPC E check digit 5 202 UPC A preamble 5 204 UPC A preamble 5 204 UPC E preamble 5 208 data transmission formats 5 200 decode options 3 6 5 169 code 128 decode performance 5 190 code 39 decode performance 5 195 decode ...

Page 346: ...ck digit verification 5 125 code 39 full ASCII 5 119 EAN 13 5 99 EAN 8 5 97 interleaved 2 of 5 5 127 interleaved 2 of 5 check digit verification 5 134 NOTIS editing 5 144 UCC EAN coupon code 5 106 UCC EAN 128 5 113 UPC A 5 93 UPC E 5 95 dual port RS 232C 2 7 E EAS 1 2 2 10 EAS interlock 5 11 disable 5 12 enable 5 11 enable Bookland EAN 5 100 CLSI editing 5 141 codabar 5 135 code 128 5 110 code 39 ...

Page 347: ...H hand held laser scanner connecting 2 8 hand held laser scanner options 5 85 beep after good decode 5 90 program all scanners 5 89 program hand held scanner only 5 85 program LS2603MX LS 3603MX LS 3203 only 5 87 program primary scanner only 5 86 program primary scanner only with LS 2603MX LS3603MX LS 3203 5 88 hardware handshaking 5 35 host options RS 232C 5 19 host types 3 5 RS 232C 5 13 I infor...

Page 348: ...e 39 5 120 interleaved 2 of 5 5 128 M maintenance 4 1 mounting LS 5700 2 12 LS 5800 2 14 stainless steel top 2 16 N notational conventions ix P parameter menus 5 1 EAS interlock 5 11 RS 232C host types 5 13 RS 232C port auxiliary options 5 56 RS 232C port host options 5 19 set default 5 5 programming 3 4 programming utilities 3 7 5 246 application items 5 258 cancel 5 256 ...

Page 349: ...ance 4 1 RS 232C host types 5 13 fujitsu 5 18 ICL 5 17 nixdorf 5 16 no host 5 14 single port 5 15 RS 232C port auxiliary options 5 56 ASCII format 5 81 baud rate 5 57 check parity 5 70 hardware handshaking 5 72 none 5 74 standard RTC CTS 5 75 parity 5 65 even 5 66 mark 5 67 none 5 69 odd 5 65 space 5 68 serial response time out 5 78 software handshaking 5 76 none 5 76 ON XOFF 5 77 ...

Page 350: ... 34 hardware handshaking 5 35 none 5 37 RTS CTS Option 1 5 39 RTS CTS Option 2 5 40 standard 5 38 parity 5 28 even 5 29 mark 5 30 none 5 32 odd 5 28 space 5 31 serial host RTS line state 5 52 serial response time out 5 47 software handshaking 5 42 ACK NAK 5 43 ACK NAK with ENQ 5 45 ENQ 5 44 none 5 42 stop bit select 5 48 RS 232C port options 3 5 S scanning bar codes 3 1 scanning made easy 1 1 scan...

Page 351: ...eters 3 5 code types and options 3 5 custom tailoring 3 5 data transmission formats 3 7 decode options 3 6 host types options 3 5 programming utilities 3 7 RS 232C port options 3 5 software handshaking 5 42 Symbol Support Center xi T technical specifications 4 4 U UCC EAN 128 A 1 unpacking 2 1 W what if 3 3 ...

Page 352: ...Index x LS 5700 LS 5800 Product Reference Guide ...

Reviews: