background image

S-71, S-72, S-73, S-74 Series

INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

IMPORTANT:

• Water lines MUST be thoroughly flushed BEFORE and 

AFTER installing the faucet to prevent foreign matter, 
i.e. copper chips, sand, stones, etc. from clogging and 
possibly damaging the sealing surface of the cartridge.

• Integral supply check included (S-73 and S-74 series only).

Note:

 

 Recommended minimum operating water supply    

pressure is 40 psi.

INSTALLATION:

(Supply stop valves must have a 3/8” O.D. compression outlet.)

1.  Apply a bead of sealant to the underside of the faucet 

escutcheon.

2. 

(S-72 and S-74 series): 

Install u-shaped anchor bar (KN-23), 

spacers (KN-26) and nuts (L-36) loosely on mounting bolts. 
Position deck plate (SPF-28) and mounting gasket (SPF-27) 
under base through sink with 

flat

 in center hole towards 

the back of sink basin. Secure by tightening nuts from 
underside. Insert faucet supply through deck plate aligning 
flat on faucet body above threaded shank with flat in deck 
plate center hole. Secure faucet to deck plate by placing the 
washer (K-60), locknut (SPF-38) and hex nut (SPF-26) on the 
supply shank. 

Hand tighten only!

 Adjust position of faucet 

to achieve optimum spray into basin. Tighten faucet securely 
to basin or deck plate. 

(S-71 and S-73 series): 

Insert faucet with flange (SPF-5) 

through hole in basin. Secure faucet to basin by placing the 
washer (K-60), locknut (SPF-38) and hex nut (SPF-26) on the 
supply shank. 

Hand tighten only!

 Adjust position of faucet 

to achieve optimum spray into basin. Tighten faucet securely 
to basin.

3.  Connect 4-10C mixing valve to bottom of supply shank using 

supply nut provided 

(S-73 and S-74 series only)

. Make 

connection to water supplies using the appropriate connectors.

4.  Install grid drain (if applicable) by removing flange and tube 

from drain body and inserting tail piece into trap. Apply 
bead of sealant to underside of flange and insert flange and 
tube through drain opening. Place bottom gasket mounting 
washer and mounting nut onto flange and tube assembly. 
Screw drain body on tube until tight.

5.  To flush faucet, remove spray outlet, using vandal proof 

wrench (LL-60K) provided with faucet. Open cold supply and 
depress handle holding down for ten seconds 

(S-71 and 

S-72 series only)

. Open hot supply and repeat above pro-

cedure 

(S-73 and S-74 series only)

. Allow faucet to shut 

off and replace spray outlet.

Temperature adjustment 

(S-73 and S-74 series only)

 

Make sure the faucet has been properly installed and thor-

oughly flushed. Set the mixing valve (4-10C) to the desired 
maximum temperature by inserting a 1/4” hex socket key 
into the mating hex socket in center of valve and turning 
counter clockwise for hotter, clockwise for colder. 110ºF 
recommended unless otherwise specified.

Adjustment of cycle time

 

After faucet has been operated through a number of cycles 
and supply water temperature is at designed level, adjust-
ment of this feature can be made as follows.

     Cycle Time:

 Faucet is factory set to shortest cycle time with 

6 timing washers (LL-28). 

      Loosen set screw (LL-27) in cap (SPF-104), remove cap. To 

increase time, remove one or more of the washers (LL-28) on 
stem. To reduce time, add washers. When desired time cycle 
is achieved replace cap and tighten set screw.

      

Note: 

When setting MAXIMUM cycle time, you MUST 

maintain  at  least  3  timing  washers  (LL-28)  so  as  not  to  exceed                                                                              
(per ASME A112.18.1) .25 gal/cycle at 60 psi.  

6  "

1

2

4  "

3

8

2  "

7

8

2  "

1

8

2  " with optional 3 hole deck plate

1

2

1  "

m ax.

1

8

"

7

8

"

1

2

    m in.

deck hole

4"

6"

optional 3 hole deck plate

2"

4"

15˚

"-14 

NPSM

1

2

"-20 

UNC

with spacer

1  "

1

8

without spacer

spacer

1

4

S-71/S-73

S-72/S-74

Metering Faucet

Summary of Contents for S-71 Series

Page 1: ...Install grid drain if applicable by removing flange and tube from drain body and inserting tail piece into trap Apply bead of sealant to underside of flange and insert flange and tube through drain opening Place bottom gasket mounting washer and mounting nut onto flange and tube assembly Screw drain body on tube until tight 5 To flush faucet remove spray outlet using vandal proof wrench LL 60K pro...

Page 2: ...PF 104 Cap and set screw SPF 104C Cap cold and set screw SPF 104H Cap hot and set screw 4 10C Mechanical mixing valve RL 266 Control spindle kit RL 267 Piston spring and cylinder kit RL 271 Mounting kit RL 272 O ring kit contains LL 44 LL 46 LL 47 LL 48 LL 49 LL 27W 3 32 hex socket key to remove handle set screw LL 60K Spray outlet wrench to remove spray outlet included with faucet Other standard ...

Page 3: ...ashers LL 35 Thrust washer LL 48 Upper housing o rings 3 LL 101 In line screen LN 100 Aerator and key vandal resistant 0 5 gpm LT 4AA Piston assembly MV 10 Rubber washer MV 107 Checks SPF 104 Cap and set screw SPF KIT Mounting Kit 4 10C Mechanical mixing valve RL 266 Control spindle kit RL 267 Piston spring and cylinder kit RL 272 O ring kit contains LL 44 LL 46 LL 47 LL 48 LL 49 LL 27W 3 32 hex s...

Page 4: ...osing on seat surface or seat washer and or seat surface worn Remove piston LT 4AA and spring LL 32 JIB Check for burr on pin LL 24 and check spring Both LT 4AA and LL 32 JIB may have to be replaced Excessive wear may require cartridge replacement LL 1A Not enough flow from faucet In line screen clogged Disassemble supply to faucet Remove in line screen LL 101 in inlet to faucet Rinse screen with ...