 ■ Connect 1

20 VAC

 line voltage to the primary side of the 

transformer as displayed in Figure 1. 

12V 

6V 

T

coil 

connections

Relay 12 VDC @ <80mA

(customer supplied option) 

Remote monitoring 

system connections

Temperature probe and 

1/4" NPT male fitting

Water hammer 

arrestor (optional)

 Tee fitting

(required, see 

options)

Alarm 

control 

module

Water flow

Transformer

12 VAC/15 VA

Solenoid valve (optional) 

12 VDC, 10 Watts max

120 VAC Power

25'probe cable

(optional lengths)

 ■ Connect the 

12 VAC

 secondary side of the transformer to 

the 

12 VAC power input 

terminals on the back of the alarm 

control module as identified in Figure 2 below. Note that 

there is no polarity required for the input terminals.

ON

OFF

Fuses #229

1.5A / 250VP

12 VAC

 power input

 12 VDC valve

 power output

(optional) 

Temperature

 input probe

DIP Switches

Rear view of Alarm Control Module

 12 VDC relay

 power output

(optional) 

 

 ■

Temperature Probe

  - Plug probe into the connector on 

the backside of the control module as identified in Figure 2 

above. Note that the connectors are keyed and will only mate 

in one direction. (optional cable lengths are available)

 ■

Solenoid Valve 

(optional)

 - 

Connect coil wires between the  

solenoid valve and the 

valve power output terminals

 on the 

back of the control module as identified in Figure 2 above. 

Note that there is no polarity required between connections.

High Temperature Audio Visual Alarm System, 

HTA-100

Installation and Service Instructions

TempControl

®

General Information

 ■

Alarm System

 - TempControl High Temperature Audio 

Visual Alarm System will monitor, alert and alarm when 

water temperature exceeds preset limit.   It best fits 

applications where there is a critical need to accurately 

monitor and control warm or hot water temperature. 

 ■

Solenoid Valve

 (optional) - When alarmed, the valve is 

de-energized and closes to provide complete shutdown of 

the water flow.

 ■

Relay

 (customer supplied option) - Installed relay enables 

remote monitoring of alarm control module.

 ■

Caution Set Point

 - is the lower of the two set point 

temperatures that alerts when the output water is 

approaching an undesirable temperature limit. 

 ■

Alarm Set Point

 - Once the output temperature reaches the 

alarm set point

, the system goes into full alarm mode.

Installation

Important: 

All piping should be thoroughly 

flushed prior to installation to prevent debris from 

interfering with the solenoid operation. 

Do not

 run 

solenoid power and temperature probe through 

same conduit.

Piping

 

 ■

Tee Fitting - 

Required; appropriate size fitting for 

application purchased seperately (see options).

 ■

Temperature Probe - 

Locate probe as far downstream from 

mixing valve as is reasonably possible.

a. Slide connector nut and ferrule piece over the probe. 
b. Slide probe 

1/2”

 to 

2/3”

 into the tee fitting. 

c. Slide the ferrule and connector nut down the probe shaft 

and tighten in place. 

 ■

Solenoid Valve

  

(optional, 12 VDC, 10 Watts

, normally 

closed) - Install valve directly before the temperature probe in 

any orientation.  Make note of the correct direction of the water 

flow as marked on the valve.

Electrical

 ■ Mount the 

4" x 4

" supplied mounting box in a dry location 

within wiring reach of the temperature probe and solenoid 

valve if used. 

 ■ Mount supplied transformer. 

(

120 VAC – 12 VAC/15 VA UL listed, CSA certified class 2)

 

Figure 1

Figure 2

For California Residents

WARNING:

 This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Summary of Contents for TempControl HTA-100

Page 1: ...mit It best fits applications where there is a critical need to accurately monitor and control warm or hot water temperature Solenoid Valve optional When alarmed the valve is de energized and closes to provide complete shutdown of the water flow Relay customer supplied option Installed relay enables remote monitoring of alarm control module Caution Set Point is the lower of the two set point tempe...

Page 2: ... condition mode will still be in effect The system will only reset when the temperature decreases below the caution set point Relay customer supplied option Connect relay coil wires between the relay and the valve power output terminals on the back of the control module as identified in Figure 2 Note that there is no polarity required between connections Fahrenheit Celsius Temperature Display Sett...

Page 3: ...rrent to valve and relay valve open relay closed no alarm System ON TRIPPED no current to valve or relay valve closed relay open alarm NOTES 1 All current values are maximums not to exceed 2 The above system design does not transmit analog or digital data to the building monitoring system 3 The above system design only provides for a binary or on off signal to the building monitoring system 4 Buil...

Page 4: ...can initiate water flowing in the system Override Position Insert the key into the control module front panel and turn the key switch to the override position The solenoid valve is held open allowing water to flow All users should be clear of the water flow due to excessive temperature flowing until the system is corrected SILENCE Keypad Button The audible signal may be silenced by depressing the ...

Reviews: