background image

19 

 

 

 

 

 

 

syride

 

®

 

SYS’Alti 

EN 

Guide d’utilisation

 : p1 

User Guide : p19  

Manual de usuario

 : p39 

Benutzerhandbuch

 : p59 

 

Summary of Contents for 13502

Page 1: ...19 syride SYS Alti EN Guide d utilisation p1 User Guide p19 Manual de usuario p39 Benutzerhandbuch p59 ...

Page 2: ...ld a unique and highly detailed online flight book Your practice of paragliding is going to take a new dimension with the SYS Alti As a member of the community you will be a key player in the evolution and continuous improvement if the instrument Sensors inside the SYS Alti allows the development of future features We encourage you to share your suggestions for your greater satisfaction Syride whi...

Page 3: ...Configure your device 25 V Advanced configuration 27 VI Customize your screens and vario sound 27 VII Screens when flying 29 VIII Flight detection and altitude setup 30 IX Display and delete a flight 31 X Warnings and reset 32 XI Transfer your flights 33 XII Parameters 35 XIII Suggestion of use 36 EN ...

Page 4: ...hecking the following website http www syride com en software 2 Follow the instructions to install it on your computer 3 Once installed an icon shows in the task bar It detects when your instrument is connected 4 The software will automatically start with your operating system 10 39 ...

Page 5: ...ator This position ables you to manipulate the instrument while flying without releasing the brakes We recommend you to insert a protection between the velcro and your riser in order to avoid the abrasion of it 2 Velcros also allow placing the instrument on a cockpit in thigh with extension or on the wrist 3 You can secure your instrument by using the strap provided for this purpose EN ...

Page 6: ...instrument will display Charging and the percentage of charge To complete a charge requires 2 hours 3 Disconnect USB to stop the charge Your instrument has a Li ion battery which has no memory effect 4 When your instrument will start the battery icon needs 10 seconds to be stable Charging 54 ...

Page 7: ... left and right buttons and confirm by clicking on central button The number of the screen is displayed on the top right of it 3 The first screen shows some informations about your instrument 4 Next screen ables you to setup the sound volume EN SYS Alti Battery 100 Memory 52 Version 1 15 S N 20142013 ...

Page 8: ...s you to setup rising and falling threshold of the vario 6 You can turn ON or OFF the backlight of your instrument on the next screen Warning backlight reduces the instrument s autonomy 7 Last screen is to go back to main screen 1 ...

Page 9: ...integration of the vario Choose the units and the language of your instrument Change any setup that is changeable inside the instrument An explanation of those functions is explained here https www syride com en support For this 1 Turn on the instrument and connect it to your computer 2 From SYS PC Tool click on configure my instrument icon 3 Change whatever you want 4 Click on Send parameters EN ...

Page 10: ...e com en ssctool Alti 2 Customize your screen by selecting an item with its size and unit and then drag and drop it to the screen 3 Download the config file to your computer 4 Turn on your instrument and connect it to your computer with USB 5 On SYS PC Tool click on Send a file to my Instrument icon 6 Select the config file you just downloaded before and disconnect your instrument done ...

Page 11: ...ton will turn OFF and ON the sound of the vario This is usefull when you need to concentrate on a transition or when landing 3 Screen 3 displays global informations concerning your flight From top to bottom these informations are o Top altitude o Min altitude o Top vario o Min vario 1435 ft 302 ft 2 1 ft m 3 1 ft m EN ...

Page 12: ...matically detects when you re flying based on the vario 2 Pressing the central button on screen 3 ables you to setup the current altitude Press left and right to select the digit you want to change and central button to change it Select the unit digit and press the central button to validate the altitude Alt Calibrate 3302 m 1435 ft 302 ft 2 1 ft m 3 1 ft m ...

Page 13: ...enter the flights list 2 You will see here every recorded flights with some informations about this flight 3 To delete a flight press the central button and confirm your action when you re asked to 4 4 EN Vol 1 Date 01 02 14 Time 12h35 Flight time 01h37 Alt max 1346m Vario max 5 4m s ...

Page 14: ...is indicated when the plane icon on the top left of the screen is blinking with a cross over it If the G Meter exceeds the value selected in advanced parameters 2 5g is the default value a highly noisy sound will activate even if the sound is turned off If ever your instrument would be stuck unresponsive to buttons plug the device to your computer with the USB cable and press the reset button with...

Page 15: ... USB cable 3 Click on Account configuration icon 4 The IGC GPX and KML files are systematically duplicated on your computer To use the advanced flight analyzer on syride com you must enter your email and password of your Syride account create one on http www syride com Make sure Use the advanced logbook from Syride com is selected to upload your flights and click OK EN 10 39 ...

Page 16: ...ook You can have access to the files on your computer by clicking on File open local directory 6 Go to your profile on the Syride website to visualize your flight altitude vario gmeter flight time gain 7 If you want you can edit some informations about your flight flight name wing flight type etc in order to generate detailed statistics ...

Page 17: ...30 Then you must transfer or delete flights to record a new one Note that flights data are automatically deleted from the device upon transfer onto the website Autonomy exceeds 100h of flight The date and time are synchronized with the date and time of your computer Flights less than a minute will be automatically deleted When recording a flight if the vario is around 0 for more than 2 minutes the...

Page 18: ...if required Otherwise the autonomy will decrease significantly A Factory Reset from SYS PC Tool Settings icon Repair allows you to get your instrument back to default state every recorded flight will be deleted When you connect your instrument to a USB charger the battery will start charging even if the instrument is turned off Feel free to customize your screens thanks to the SSCTool http www syr...

Page 19: ...tery clean thoroughly with water and seek medical advice immediately For safety reasons and to extend battery life charging can be done in an ambient temperature range Temperatures Standard operation 0 C 32 F to 45 C 113 F short term storage 20 C 4 F at 60 C 140 F Storage long term 20 C 4 F at 25 C 77 F Do not check out or do not attempt to remove the battery which is not user replaceable If batte...