background image

Document in original language | 254494 · v01

SAVE VTR 150/K

Installation instructions

GB

Summary of Contents for SAVE VTR 150/K

Page 1: ...Document in original language 254494 v01 SAVE VTR 150 K Installation instructions GB...

Page 2: ...s the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair is not liable or bound by...

Page 3: ...Transport Storage 5 4 1 Transport and storage 5 4 2 Delivery Unloading 5 5 Prerequisites for Installation 5 5 1 Where how to install 6 5 2 Wall preparation for mounting bracket 6 5 3 Outdoor Air Intak...

Page 4: ......

Page 5: ...e of the unit Fig 1 Type label Position Description 1 Product code product specification 2 Product item number 3 Production order number 4 Serial number 5 Production date YY MM DD 6 Scannable code for...

Page 6: ...experience and knowledge if no instruction concerning the use has been given by the person responsible for their safety or that this person is supervising the operation Children should be supervised...

Page 7: ...Technical Data 3 3 2 Dimensions and Weight Fig 2 Dimensions and weight L model The unit weight is 85 kg 254494 v01...

Page 8: ...to be stopped by the user manually or due to calendar function we recommend to install air tight dampers at ex tract and supply air ducts The dampers will ensure that no air circulates from the warm p...

Page 9: ...d be stored and transported in such a way that it is protected against physical damage It should be covered so dust rain and snow cannot enter and damage the unit and its components Important Use the...

Page 10: ...nstallation location for the outdoor air intake is the northern or eastern side of the building and with a distance to openings for discharge of stale ventilation air kitchen ventilator central vacuum...

Page 11: ...lation 7 C concrete bricks W wood block G gypsum M mineral wool X adaptable height according to needs SAVE VTR 150 K should be installed more than 2 3 m above the floor or any other needed height 2544...

Page 12: ...ly without any gaps otherwise there is a risk of condensation which may result in moisture damage Do not install the ducts directly against structural building elements to avoid sound propagation Use...

Page 13: ...uit board connections Position Description CB Connection to the external connection box 1 Terminals for a heater 2 Terminals for a TRIAC 3 Terminals for the mains power supply 4 Terminals for power su...

Page 14: ...extract air fan 17 Terminals for speed control of supply air fan 7 2 External connections Connection board External connections to the main circuit board are done via connection board situated inside...

Page 15: ...ected to the unit All ducts are sufficiently insulated and installed according to local rules and regulations Outdoor air intake is positioned with sufficient distance to pollution sources kitchen ven...

Page 16: ...site 1 Ensure that the product is operational and that no alarms are active 2 If applicable save the configuration backup 3 Make sure that the Commissioning record is complete 4 Collect all tools 5 I...

Page 17: ...l appliances Part 2 40 Particular requirements for electrical heat pumps air conditioners and dehumidifiers EN 50106 Safety of household and similar appliances Particular rules for routine tests refer...

Page 18: ...SAVE VTR 150 K Installation instructions 254494 en_GB 2021 02 19 v01 Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 60166 www systemair com...

Reviews: