background image

TECHNICAL MANUAL

v1.09

NB-NHB Series

Precision Balance

V1.05-v1.17

REV:Y1, July,2016

Summary of Contents for NB Series

Page 1: ...TECHNICAL MANUAL v1 09 NB NHB Series Precision Balance V1 05 v1 17 REV Y1 July 2016...

Page 2: ......

Page 3: ...pyright by TScale Electronics Mfg Kunshan Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Taiwan scale...

Page 4: ...ON 5 4 INSTALLATION 7 5 DESCRIPTION 9 6 OPERATION 11 6 1 Power ON OFF 11 6 2 Zero 11 6 3 Tare 11 6 4 Weighing Unit 11 6 5 Percent Weighing 12 6 6 Parts Counting 12 6 7 Accumulation 13 6 8 Set Backligh...

Page 5: ...to or destruction of the equipment The weighing scale is a precision electronic instrument handle it carefully Do not install the scale in direct sunlight Verify the local voltage and receptacle type...

Page 6: ...s of general purpose balances with counting weighing functions and accumulation 16 5 mm LCD with white LED back light display All the keypads are light touch switches Battery provide up to 90 hours of...

Page 7: ...500g 3000g 6000g Readability d 0 002g 0 005g 0 01g 0 02g 0 05g 0 1g Readability e 0 02g 0 05g 0 1g 0 2g 0 5g 1g Resolution 1 7 500 1 6 000 1 6 000 1 7 500 1 6 000 1 6 000 Tare range 149 998g 299 995g...

Page 8: ...tic Stainless Steel platform Pan Size 80mm 120mm 140 150mm Overall Dimensions wxdxh 190mm x 220mm x 60mm Other Features and Specs Accuracy enhancement for parts counting and percentage weight function...

Page 9: ...ging Battery To charge the battery insert the adaptor pin to jack jack is locating rear side of the scale Adaptor simply plug into the mains power The scale no needs to be turned on The battery should...

Page 10: ...ontact Turn on the On Off key If you want to turn off press the key again Display will be show the version number and will be starting self checking After self checking display will be come to normal...

Page 11: ...ical Manual 9 5 DESCRIPTION Key Board Turns the scale power On Off Sets display to Zero Subtracts weight of container Set percentage weighing function Set to counting mode Set to weighing units Set to...

Page 12: ...ndicator for Tare display Indicator for weighing capacity graph Indicator for Net weight Indicator for Display stability Indicator for piece counting Indicator for units Indicator for Percent weighing...

Page 13: ...an set the display of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero 6 3 Tare The weight of any container can be tared by pressing button so that w...

Page 14: ...the basis of greater numbers of samples improves the accuracy of percentage large quantities 6 6 Parts Counting Parts Counting Press key enter the parts counting mode and select the counting options b...

Page 15: ...Display will be show then will be show the total saved value These displays will be shown only three seconds If the optional RS 232 interface is installed the weight data will be send to printer Remo...

Page 16: ...pe language press key to escape Operation Place the load on the platform after stable you will hear beep on twice add or remote weight scale will beep on again after stable Remove the weight from the...

Page 17: ...oose menu block or options one by one Enter the Selected Menu Press it can confirm which will be shown displayed Enter in to TECH Note Before enter the tech menu press calibration switch which is loca...

Page 18: ...ta Command T Tare Command Z Zero Wirele Wireless optional Set BAUD rate After setting the RS 232 mode display will be shown current baud rate b XXX Baud rate Options b600 b1200 b2400 b4800 and b9600 S...

Page 19: ...ng the internal counts P 4 a 2n N A P 5 gra XXXXX To set local gravity P6 cap 60g 150g 300g 600g 1500g 3 000 g 6000 g To set Capacity P7 spd Spd l Speed low To set AD speed Spd m Speed medium Spd h Sp...

Page 20: ...zero indicator on display will be shown L oad 2 Place the calibration weight 2 3 of the capacity on the platform After stable and zero indicator on display will be shown L oad3 Place the calibration w...

Page 21: ...bits No Parity 2 RS 232 9pin D type connector Pin RXD Input Receiving data Pin TXD Output Transmission data Pin GND Signal ground 9pin D Connecter Indicator Computer Printer Pin 2 Pin 3 Pin 3 Pin 2 P...

Page 22: ...NB NHB Series Technical Manual 20 10 DRAWING...

Page 23: ...NB NHB Series Technical Manual 21...

Page 24: ...a must be 0 5d Err 8 Calibration weight error Check the test weights for calibration or linear calibration Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Che...

Page 25: ...heck the printer settings or connections Err l Approval setting error Check the PCB jumper settings Must be connect jumper pin to K1 BW series ol Over range Remove the load Re calibrate lo Underload M...