http://www.tandd.com/
Shimadachi 817-1, Matsumoto, Nagano 390-0852 Japan
Facsimile: +81-263-40-3152 E-MAIL: support@tandd.com
Notices about this Manual and Disclaimers
In order to properly use this product, please carefully read this Manual before using.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble
with this product or with your computer that is caused by the improper handling of
this product and will deem such trouble or malfunction as falling outside the
conditions for free repair outlined in the attached warranty.
- All rights of this Introductory Manual belong to T&D Corporation.It is prohibited to use,
duplicate and/or arrange a part or whole of the Manual without the permission of T&D
Corporation.
- All registered trademarks, company names, product names and logos mentioned herein or for
products being used are the property of T&D Corporation or of their respective
owners."TANDD", "T&D" and the logo of T&D Corporation are all registered property of T&D
Corporation.
- Specifications, design and other contents outlined in the Manual are subject to change
without notice due to continual improvements.
- Please follow the safety precautions outlined in the Manual carefully.We cannot guarantee nor
are we responsible for safety if this product is used in any manner other than was intended.
- On-screen messages in this Manual may vary slightly from the actual messages.
- Please notify the distributor from which you purchased this product or T&D Corporation of
any mistakes, errors or unclear explanations in this Manual.T&D Corporation accepts no
responsibility for any damage or loss of income caused by the use of our product.
- This product has been designed for private or industrial use only.It is not for use in situations
where strict precautions are necessary such as in connection with medical equipment, where
directly or indirectly.
- We are not responsible for any malfunction or trouble caused by the use of our product or for
any problem caused by the use of measurement results of our product. Please be fully aware
of this before using our product.
- This Introductory Manual cannot be reissued, so please keep it in a safe place.
- Please read the warranty and provisions for free repair carefully.
Cautions about using "log-EZ" (RTR-322)
Danger
Do not take apart, repair or modify the Unit.
It may cause electrocution or damage. Ask the shop where you purchased the products
or T&D Corporation to carry out any repairs.
If any smoke, strange smells or sounds are emitted from the Unit,
immediate remove the battery and stop using.
Continued use may cause fire, electrocution or damage.
This unit is not water resistant. If water or a foreign object enters the case, immediately
remove the battery and stop using it.
Do not use any other batteries than those that are specified in this Manual.
It may cause a fire or malfunction.
Do not use and store the Unit in areas near fire or exposed to excessive
heat.
If water or a foreign object enters the case, immediately cease using it.
Swallowing batteries is extremely dangerous.
Store the Unit and batteries out of the reach of children.
The "log-EZ" is a device to measure temperature and humidity. Do not use
it for any other purpose than to measure temperature and humidity.
Caution
This Unit has been designed for private or industrial use only. It is not for
use in situations where strict precautions are necessary such as in connec-
tion with medical equipment, where directly or indirectly.
Do not drop or expose the Unit to a strong impact.
It may cause damage or malfunction.
Battery terminals may provide insufficient contact due to age or vibration.
This may lead to data loss.
Battery life varies depending upon the type of battery, the measuring
environment, the frequency of communication, the ambient temperature,
and the battery performance.
Please make sure to use the latest version of Software.
The latest version can be downloaded free of charge from our T&D Website.
Contact with oil may cause cracks to appear in the casing of the Unit.
When using the Unit in environments where such oils are present, please
insure that it is protected from contact through use of a polyethylene bag
or other means.
If the Unit is not to be used for a long period of time, for safety reasons
please remove the battery.
If left in the Unit, the battery may leak and lead to malfunctioning.
Introductory Manual
Thank you for purchasing our product.
Carefully read this Introductory Manual
before using this product.
© Copyright T&D Corporation. All rights reserved.
2016.11 16504740026 7th Edition
Package Contents
The following items are included in the package:
Introductory Manual
(this document)
AA Alkaline
Battery × 1
Wireless Dongle
Base Unit (RTR-300)
"log-EZ"
Remote Unit (RTR-322)
Stand × 1 / Screw × 2
- Software is not included in the package. Please visit our T&D
Website and download the software from the Support Page.
- The Wireless Dongle is only supplied in the Wireless Dongle Set.
- From hereafter in this manual, the "Wireless Dongle" will be
referred to as "Dongle".
How to Use the Stand
Slightly bend the stand into a curved shape, and insert the "log-EZ"
unit through the round holes of the stand so that the stand holds the
"log-EZ". It can then be placed on a flat surface such as a table or
desk, or by using the supplied screws hung on a wall.
Specifications
"log-EZ" RTR-322
Number of Channels
2 ch (Temperature / Humidity)
Measurement Items
Temperature
Humidity
Measurement Range
0 to 50°C
15 to 90%RH
Display Resolution
0.1°C
1%
Accuracy
±0.5°C (0 to 50°C)
±5%RH (At 25°C 50%RH)
LCD Refresh Interval
1 sec.
Recording Interval
10 min. (Fixed)
Logging Capacity *1
1,440 data sets (One data set consists of readings for temperature and
humidity.
Operation
Mode
Registration Mode
After inserting battery: 5 min. (For First Remote Unit Registration) / 2
min. (For Battery Replacement)
Recording Mode
Overwrite the oldest data when capacity is full
LCD Display Items
Measurement and Recording Status / Amount of Recorded Data /
Communication Status / Recording Mode / Battery Life Warning /
Measurements (Temperature and Humidity: alternating display) /
Unit of Measurement
Communication Method
Wireless Communication (internal antenna) between "log-EZ"(RTR-322)
and "Dongle"(RTR-300)
Dimensions
Tubular Shape: Dia 36mm × L 85mm
Weight
Approx. 40 g
Power
AA Alkaline Battery × 1
Battery Life
About 6 months *2
Radio Standard Specifications
FCC Part15 Section247 / IC RSS-210 / ETSI EN 300 440-2
(Frequency Range: 2433 to 2482MHz) *3
Wireless Communication Range
About 50 meters [160ft] (if unobstructed and direct)
Operating Environment
Temperature: 0 to 50°C *4 / Humidity: 90%RH or less (without condensation)
log-EZ for Windfows
Compatible OS *5
Microsoft® Windows® 10 32bit / 64bit
Microsoft® Windows® 8 32bit / 64bit
Microsoft® Windows® 7 32bit / 64bit
Microsoft® Windows Vista® (SP1 or later) 32bit
Display Languages *6
English
Other
The Microsoft .NET Framework 3.5 (SP1) is required.
Wireless Dongle RTR-300
Dimensions
L79.5 × W19.5 × D9.4 (mm)
Weight
Approx. 10 g
Power
USB Bus Power (5V)
Wireless Specifications
FCC Part15 Section247 / IC RSS-210 / ETSI EN 300 440-2
(Frequency Range: 2433 to 2482MHz) *3
Wireless Communication Range
About 50 meters [160ft] (if unobstructed and direct)
Operating Environment
Temperature: 0 to 50°C / Humidity: 90%RH or less (without condensation)
Interface
USB
*1. Logging Capacity is the amount of data which can be logged in the unit; when the capacity is full, the oldest data
is overwritten and recording continues.In order to store data continually, a PC is needed to receive data.
*2. Battery life varies depending upon measuring environment, frequency of communication, and battery performance.
(Example: If used at an interval of 1 min. to collect current readings, battery life expectancy is about 1.5 months.)
*3. This Unit is not for use with a wireless LAN.
*4. In environments where the temperature exceeds or falls below this range, there may be occasions when the
recorded data is lost.
*5. IFor installation, it is necessary to have Administrator (Computer Administrator) rights.
*6. We recommend using an operating system in the same language as the display language. Operation in different
languages is not guaranteed.
The specifications listed above are subject to change without notice.
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of this product, and for protecting yourself and other people from bodily harm and/or damage to property.Before
using this product, please carefully read, understand and follow the safety rules and precautions outlined below.
Cautions about using the
"
Dongle
"
(RTR-300)
Danger
Do not take apart, repair, or modify.
It may cause electrocution or damage.Ask the place of purchase or T&D Corporation to
carry out any repairs.
Do not store, leave, or use in any places subject to high temperatures such
as direct sunlight or near heating equipment, or to extremely low
temperatures.
Make sure not to get it wet.If it does get wet, immediately stop using.Do
not use or store in humid places such as a bathroom.
Do not use in or near fire, nor directly put into cooking equipment such as
a microwave oven or a high pressure cooker.
Caution
This is a precision piece of equipment.Do not expose to strong impact or
throw it.
Before touching the "dongle" to install or remove, please first touch metal
around you (steel desk, door knob) to clear static electricity.
Set and store out of the reach of infants.
If and when a child is to use the product, make sure they are given proper
instructions on how to use it.
Do not touch with wet hands.
Do not connect to a PC using a USB hub.
This product is not for saving data.
Explanation of Warning Symbols
Danger
These entries are actions that absolutely under no circumstance
should be taken. The taking of such an action may cause serious
personal physical damage or death.
Caution
These entries are actions that if taken may lead to physical injury
or damage to persons or things.
Explanation of Picture Symbols
Denotes an important warning or caution.
Denotes a forbidden action.
Denotes an action that must be taken.
Important Notice
Wireless products cannot be used in countries other than where those products
have been approved for use, according to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage of
these products, nor be liable in any manner for legal consequences stemming from
the usage of these wireless products in unapproved areas.
Compliance Information
CE Statement
This device complies with technical specifications required under EN
301 489 (with battery and AC Adaptor), EN 300-440, and EN 60950-1.
Compliance Information
FCC Statement
This device complies with Part 15 of the Federal Communications Commission
(FCC) rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Note about Antenna Usage:
This device has been designed to operate with the
supplied antenna only. Use of any other antenna is strictly prohibited.
IC Statement
This device complies with RSS-210 of the Industry Canada (IC). Operation is subject
to the following two conditions: (1) This device may not cause harmful interference;
and (2) This device must accept any interference received, including interference
that may cause undesired operation.
Ce dispositif est conforme à la norme RSS 210 d’Industrie Canada.
L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il
ne doit pas produire de brouillage et (2) l’utilisateur du dispositif doit être prêt à
accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible
de compromettre le fonctionnement du dispositif.