Safety Precautions and Instructions
To ensure safety obey all of the following warnings.
The following items should be strictly obeyed for the safe usage of this product, and for protecting yourself and other people from bodily harm and/
or damage to property. Before using this product, please read the following carefully and fully understand the contents.
DANGER
Failure to follow the instructions with this symbol could cause serious injury or even death.
DO NOT USE THIS PRODUCT IN WAYS OTHER THAN ITS IN-
TENDED PURPOSE
This product has been designed to measure the
temperature of food and liquids. Do not use it for any
purpose other than for which it was designed.
Because the sensor has a sharp tip, there is a risk of
accidentally stabbing people and/or objects. Do not
use the sensor for any purpose other than measuring
the temperature of objects for which it was designed.
PLACE AND STORE IN A SAFE PLACE
Avoid placing the unit in unstable areas
exposed to vibration, slippery surfaces,
or within reach of small children. When
not in use, put a cover on the sensor
tip and store in a safe place.
CLEAN and STERILIZE UNITS BEFORE
AND AFTER USE
Before and after
using, please clean
to remove any
substances attached
to the surface and
sterilize the units in
order to prevent the
growth of bacteria.
If a unit gets dirty or oily, wipe it with a
clean cloth dipped in alcohol.
NEVER use an acid, alkaline, or chlorine based
detergent. This will cause harm to the electric
components in the unit or the battery charger.
DO NOT TOUCH SENSOR IMME-
DIATELY AFTER MEASUREMENT
Please be careful when using in
extreme hot or cold environments;
touching the unit may cause burns
or frostbite.
CAUTION
Failure to follow the instructions with this symbol could
cause personal injury or physical damage to equipment.
- Do not disassemble, repair or modify the unit and/or accessories.
- Do not forcibly insert the sensor into hard objects such as frozen food.
It may cause to sensor breakage, leading to unexpected accidents
and injury.
- Do not cut or process the sensor cables. Also, do not twist, pull or
swing any of the cables.
- We are not responsible for any damage, malfunction or trouble,
whether direct or indirect, caused by the use of our product.
- To prevent damage to the unit from static electricity, remove static
electricity from your body before touching the unit.
Important Notices and Disclaimers
In order to properly use this product, please carefully read this document
before using.
- All rights of the attached documents belong to T&D Corporation. It
is prohibited to use, duplicate and/or arrange a part or whole of the
attached documents without the permission of T&D Corporation.
- All registered trademarks, company names, product names and logos
mentioned herein are the property of T&D Corporation or of their
respective owners.
-
Specifications, design and other contents outlined in this document
are subject to change without notice.
- Please follow the safety precautions outlined in this document
carefully.
- We cannot guarantee nor are we responsible for safety if this product
is used in any manner other than was intended.
- On-screen messages in this document may vary slightly from the
actual messages.
- Please notify the shop where you purchased this product or T&D
Corporation of any mistakes, errors or unclear explanations in this
document.
- T&D Corporation accepts no responsibility for any damage or loss of
income caused by the use of our product.
- Please read the warranty and provisions for free repair carefully.
Information Regarding Product Disposal
- This product contains recyclable Ni-MH batteries.
- If you wish to dispose of the unit, please contact your local distributor.
Compliance Information
This device complies with Part 15 of the FCC rules and RSS-210
of Industry of Canada. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Ce dispositif est conforme à la norme RSS 210 d’Industrie Canada.
L’utilisation de ce dispositif est autorisée seulement aux conditions
suivantes : (1) il ne doit pas produire de brouillage et (2) l’utilisateur
du dispositif doit être prêt à accepter tout brouillage radioélectrique
reçu, même si ce brouillage est susceptible de compromettre le
fonctionnement du dispositif.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
Part Names and Functions
1
LED (Orange)
By pressing the <REC> button, the lamp will turn on when a temperature
measurement is recorded.
2
Judgement LED
(Red / Green)
The judgement result of temperature measurement will be shown.
Out of Range: Red LED will blink. Within Range: Green LED will blink.
3
<REC> Button
When this button is pressed, the Temperature, Date / Time, User
Name, Item, and Judgement Result at the time of pressing are
recorded into the RTR-601.
4
Operation Buttons
<ENT>
Press to enter the settings menu or confirm a setting.
<MENU>
By pressing this button, the menu will be displayed. Also, press to
return to the previous screen.
Press to move the arrow cursor up and down or scroll the screen.
5
Power Button
Press to turn the power ON or OFF. The automatic power-off function
automatically turns off the power after about five minutes of inactivity.
6
Optical Communi-
cation Area
Do not shield the communication area with a tape as it may cause
communication errors.
RTR-601 Series is referred to as simply the "RTR-601", "unit" or "Remote Unit" in this
document.
Sensor Tip Shape
Each sensor type has a different tip shape: the long type sensor has a round
tip; and the short type sensor has a sharp tip (for piercing target object).
Sensor Materials: Stainless Steel (SUS316)
Handgrip Materials: Flame-retardant PPE/PA6 (Temperature Durability: About 170°C)
Cable Materials: Fluoropolymer Coated Electrical Wire Cable Length: 900 mm
T&D CORPORATION
tandd.com
© Copyright T&D Corporation. All rights reserved.
2020. 11 16504390045 4th Edition
Wireless Food Core Temperature
Data Logger
RTR-601 Series User's Manual
Thank you for purchasing our product.
Carefully read this instruction manual before using this unit.
Specifications
Measurement Channels Temperature 1ch
Sensor
Platinum Resistance (Pt1000)
Measurement Units
°C , °F
Measurement Range
-60 to 250°C
Accuracy
±0.5°C at -10 to 150°C
±1.0°C at -60 to -10°C, 150 to 250°C
Measurement Resolution 0.1°C
Responsiveness
Thermal Time Constant:
Approx. 12 sec. (in air) / Approx. 2 sec. (in agitated water)
Response Time (90%):
Approx. 60 sec. (in air) / Approx. 3 sec. (in agitated water)
Measurement
/ Display Interval
0.5 sec.
Recording Items
Temperature, Measurement Time, User, Item, Judgement Result
Logging Capacity
1,800 readings
Recording Mode
Endless (Overwrite oldest data when capacity is full)
Communication
Interfaces
Short Range Wireless Communication
Frequency Range: 902 to 928MHz
RF Power: 7mW
Optical Communication
Wireless Transmission Range Approx. 50 meters
Communication Time
Data Download Time between RTR-601 and Base Unit:
Approx. 2 minutes (for 1,800 readings)
An additional 30 seconds should be added for each Repeater. (*1)
Power
Two included AAA Ni-MH batteries (Non-Contact Charging System) (*2)
Battery Life
Approx. 24 hours (for Continuous Operation with Backlight Always ON)
Dimensions
H 165 mm × W 49.8 mm × D 37 mm (excluding sensor)
Sensor Length: Short type 135 mm, Long type 310 mm
Cable Length: 900 mm
Weight
RTR-601-110 (Short Sensor) Approx. 135 g
RTR-601-130 (Long Sensor) Approx. 150 g
RTR-601-E10 (Cable Type Short Sensor) Approx. 185 g
RTR-601-E30 (Cable Type Long Sensor) Approx. 200 g
Operating Environment -10 to 60°C
Waterproof Capacity
IP68: Submersible
Software (*3)
Base Unit/Repeater Settings: RTR500BW for Windows
Remote Unit Settings: RTR500BW for Windows (for RTR-601)
Compatible Base Units /
Repeaters
Base Units: RTR500BW / 500BC (*4), RTR-500NW / 500AW / 500 (*4)
Repeaters: RTR500BC, RTR-500
*1: When using RTR500BW as Base Unit and RTR500BC as Repeater. Depending upon conditions
it may take up to an additional 2 minutes.
*2: A Battery Charge Dock (RTR-600BD) needs to be purchased separately.
*3: Software can be downloaded free of charge from T&D Website.
*4: Customers wishing to use the RTR500BC or RTR-500 as a Base Unit, please contact your
local distributor for the communications protocol specifications to write your own software.
The specifications listed above are subject to change without notice.
Common Accessories: Manual Set (Warranty Included)
RTR-601-110
RTR-601-130
RTR-601-E10
RTR-601-E30
Before Using this Product
• The RTR-601 Series Units function as Remote Units. They require Base Units to carry out wireless communication. Before getting ready and
setting up the Remote Unit, make sure to first get ready and setup the Base Unit(s).
• To use RTR-601 Series Units, it is necessary to make operation settings via the software ”
RTR500BW for Windows (for RTR-601)”
.
For details about the operation settings via the software, refer to the ”
RRTR-601 Setup Guide (PDF)
”. Both the software and manual
can be downloaded from the T&D Website.
• To carry out setup of RTR-601 Series Units, a Battery Charge Dock with USB communication function “RTR-600BD” (sold separately) is also necessary.