When connecting the unit to your PC, make sure to follow all warnings
and directions from your computer manufacturer.
»
We shall not guarantee the unit's operation if it has been connected to a
PC using a USB hub or a USB extension cable.
»
Do not insert any foreign objects into any of the units' jacks.
»
If the unit gets dirty, wipe it with a clean cloth.
»
Make sure to remove dust and dirt from plugs of any cables.
»
Battery terminals may provide insufficient contact due to age or vibration.
This may lead to data loss.
»
Please note that this document has been written based on the presup-
position that details about contracts with an Internet provider, specific
network environments and the set-up of any other necessary equipment
to enable network connection has already been taken care of by the User
and that connection has been confirmed as workable. T&D Corporation
shall not be responsible for any damages which a contractor, a user or
a third party may suffer, whether direct or indirect, due to the inability to
communicate or use communication devices.
CAUTION
Notices about Sensors
»
Do not connect any sensor to the unit other than those specified by T&D
Corporation.
»
Make sure to use sensors within the measurement range indicated in the
specifications for that sensor.
»
Do not connect the sensor to any data logger other than those specified
by T&D Corporation.
»
Do not expose the sensor to a strong impact. This may adversely affect
measurement accuracy and cause damage or malfunction.
»
When the sensor is not to be used for a long period of time, please store it
at normal temperature and humidity.
»
Do not use the sensor on the human body.
Temperature-Humidity Sensor
»
If extremely severe temperature changes occur, it may result in large errors
in humidity measurement. Once the sensor's temperature becomes stable,
the measurements will return to normal.
»
The temperature-humidity sensors will with normal use experience losses
in precision and sensitivity over time due to degradation. If the sensor is
being used in an unsuitable environment (smoky or dusty places) it may
be necessary to change the sensor sooner.
»
The included sensor is not water resistant. If the sensor gets wet, imme-
diately remove the sensor from the unit and wipe it with a clean cloth as
soon as possible. Then allow the sensor to dry in normal room tempera-
ture before using it again.
»
When using the sensor in an environment where the humidity is under
30 %RH, the measurements may sometimes fluctuate. This is not abnormal.
»
Do not expose to condensation, dampness, corrosive gases, or organic
solvents.
Thermocouple Sensors
»
We do not handle the sale of Thermocouple sensors. Please prepare a
commercially available sensor.
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of
this product, and for protecting yourself and other people from
bodily harm and/or damage to property.
Explanation of Symbols
<Warning Symbols>
DANGER
These entries are actions that absolutely under no
circumstance should be taken. The taking of such an action
may cause serious personal physical damage or death.
CAUTION
These entries are actions that if taken may lead to physical
injury or damage to persons or things.
<Picture Symbols>
Denotes an
important warning
or caution.
Denotes a
forbidden action.
Denotes an action
that should not be
carried out.
DANGER
To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and/or accessories.
Do not use the unit in any environment that is exposed to chemicals
and harmful gases. Doing so may cause corrosion and/or other dan-
ger to the unit. Also, coming in contact with hazardous substances
may cause bodily harm to the user or people nearby.
This product is not water resistant. If water or a foreign object enters
the case, immediately remove batteries and stop using it.
Do not touch the unit or AC adaptor during thunder and lightning, as
this may cause electrocution.
Do not handle the unit, remove batteries or cables with wet hands.
This product has been designed for private and/or industrial use only.
It should not be used in situations where strict safety precautions are
necessary such as with medical equipment, or in systems directly or
indirectly connected with human life or well-being.
Do not drop or expose the unit to a strong impact.
Do not cut or process the cords for the communication cables. Also,
do not twist, pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static
electricity from your body by touching metal around you (such as a
door knob and window frame) before touching the unit.
Place and store the unit and accessories out of the reach of children.
We are not responsible for any damage, malfunction or trouble,
whether direct or indirect, caused by the use of our product.
Do not use any battery, sensor, or cable other than those specified
by T&D Corporation.
Do not put anything on top of the cable or the unit. This may cause
overheating.
Do not disconnect the USB cable during USB communication. Doing
so may cause adverse effects to the unit and/or PC.
Make sure that sensor and cable plugs are all inserted fully, so as not
to cause an improper connection. Also, when unplugging the cable
from the unit, do not pull the cord, but hold the connector to discon-
nect.
If the unit produces heat, emits smoke or a strange smell, or makes
unusual noise, immediately remove the batteries and stop using it.
Also, unplug the unit from the PC.
If the unit is not to be used for a long period of time, remove batter-
ies. Leaving batteries inside the unit may cause battery leakage and
malfunction. Install new batteries when starting or re-starting to use
a unit.
For TR-75wb / TR-75nw: Ch.1 and Ch.2 terminals are NOT electrical-
ly isolated from each other. Do not attach non-isolated thermocouple
sensors to objects connected to a live voltage. This may cause a
short circuit or an electrical shock.
CAUTION
Do not place or store in the following areas:
»
Areas exposed to direct sunlight
»
Areas subject to direct flames or heaters, as well as areas in which hot air
accumulates and creates extremely high temperatures
»
Areas exposed to static electricity
»
Areas exposed to strong magnetic fields
»
Areas exposed to water leakage
»
Areas subject to condensation or wet areas
»
Areas exposed to excessive vibration
»
Areas exposed to excessive smoke, dust or dirt.
CAUTION
Other Precautions
»
Use the unit in the specified operating environment. Do not use it for any
purpose other than for which it was designed.
»
Condensation may occur inside the case when a unit is moved from one
environment to another where there is a great difference in temperature.
»
Do not use the unit in wet areas or places exposed to water such as bath-
room.
TR-7wb/nw Series Thermo Recorder
Please Read First
Package Contents
TR-71wb / TR-71nw
Temperature 2ch
Data Logger
Temperature Sensor
TR-0106 x 2
AA Alkaline Battery
(LR6) x 2
USB Mini-B Cable
(US-15C)
Manual Set
(Warranty Included)
Registration Code
Label
TR-72wb / TR-72nw
Temperature 1ch, Humidity 1ch
Data Logger
Temperature-Humidity
Sensor THA-3001
AA Alkaline Battery
(LR6) x 2
USB Mini-B Cable
(US-15C)
Manual Set
(Warranty Included)
Registration Code
Label
TR-72wb-S / TR-72nw-S
Temperature 1ch, Humidity 1ch
(High-Precision Type)
Data Logger
High Precision
Temperature-Humidity
Sensor SHA-3151
AA Alkaline Battery
(LR6) x 2
USB Mini-B Cable
(US-15C)
Manual Set
(Warranty Included)
Registration Code
Label
TR-75wb / TR-75nw
Thermocouple (K, J, T, E, S, R) Temperature 2ch
Data Logger
AA Alkaline Battery
(LR6) x 2
USB Mini-B Cable
(US-15C)
Manual Set
(Warranty Included)
Registration Code
Label
* Please prepare a thermocouple separately. T&D does not handle the sale of thermocouple sensors.
GettingLogger Ready for Installation
Battery Installation & Sensor Connection
Battery
Make sure to use new
batteries (including for
replacement) and insert
in the correct direction.
TR-71wb / TR-71nw
TR-72wb / TR-72nw
TR-72wf-S / 72nw-S
About TR-71wb / TR-71nw Internal Sensor
Channel 1 has an internal temperature sensor. When an external sensor is not connected, the
internal sensor will be used.
About TR-75wb / TR-75nw Input Terminal
When connecting thermocouple wires to the input terminal, make sure that the positive and
negative connections are in the proper order. If the polarity is incorrect, changes in temperature will
be reversed (when the real temperature increases, the measured temperature will decrease).
Wiring Connections
Connect and disconnect the thermocouple wire from the hole while
pressing the input terminal button with a screwdriver or other such tool.
Do not try to pull out the wire without pressing the button.
Compatible Wires
Single wire: 0.32 to 0.65
(AWG 28-22)
Twisted wire: 0.08 to 0.32
(AWG 28-22)
Diameter: 0.12
or more
Strip length: 9 to 10
Strip
Button
Using GND
If measurements are unstable while using external power (USB or PoE), connect to the GND terminal.
»
See the Introductory Manual for how to set and check thermocouple sensor type for TR-75wb / TR-75nw.
»
The Introductory Manual also explains operations using the operation buttons.
TR-71wb / 72wb / 75wb
(Wireless LAN)
TR-71nw / 72nw / 75nw
(Wired LAN)
TR-71wb / TR-71nw
TR-72wb / TR-72nw
TR-72wf-S / 72nw-S
TR-75wb / TR-75nw
Operation Buttons
Battery Cover
USB Port
Sensor Jack
Channel 1
Sensor Jack
Channel 2
(TR-71wb / TR-71nw only)
Power Button
Thermocouple
Input Terminal
Ethernet Port (LAN)
PoE LED
turns ON when running on
external power.
LINK LED
flashes during network
communication.