background image

Installation and 

Maintenance

Instructions

Limited Three Year Warranty

(Commercial Applications)

 T&

S warrants to the original purchaser (other 

than for purposes of resale) that such product is 

free from defects in material and workmanship for a 

period of three (3) years from the date of purchase.  

During this three-year warranty period, if the product 

is found to be defective, T&S shall, at its options, 

repair and/or replace it.  To obtain warranty service, 

products must be returned to...

T&S Brass and Bronze Works, Inc.

Attn:  Warranty Repair Department

2 Saddleback Cove

Travelers Rest, SC  29690

  Shipping, freight, insurance, and other 

transportation charges of the product to T&S and 

the return of repaired or replaced product to the 

purchaser are the responsibility of the purchaser.  

Repair and/or replacement shall be made within a 

reasonable time after receipt by T&S of the returned 

product.  This warranty does not cover Items which 

have received secondary finishing or have been 

altered or modified after purchase, or for defects 

caused by physical abuse to or misuse of the 

product, or shipment of the products.

  Any express warranty not provided herein, and 

any remedy for Breach of Contract which might 

arise, is hereby excluded and disclaimed.  Any 

implied warranties of merchantability or fitness for 

a particular purpose are limited to three years in 

duration.  Under no circumstances shall T&S be 

liable for loss of use or any special consequential 

costs, expenses or damages.

  Some states do not allow limitations on how 

long and implied warranty lasts or the exclusion or 

limitation of incidental or consequential damages, 

so the above limitations or exclusions may not apply 

to you.  Specific rights under this warranty and other 

rights vary from state to state.

Attention California Residents:

     

WARNING

 This product can expose you to 

chemicals including Lead, Chromium (hexavalent 

compounds) and Phthalates (DEHP) which are 

known to the State of California to cause cancer 

and birth defects or other reproductive harm.

For more information go to

www.P65Warnings.ca.gov.

 

P/N:  098-016361-45  Rev.12  

 

Date: 08-06-21

 

Drawn: TED

  Checked:  DMH 08-27-21

  Approved:  JHB 09-01-21

EC-3100 Series

ChekPoint

ELECTRONIC SENSOR OPERATED

FAUCET:

• DECK MOUNT & WALL MOUNT

• GOOSENECK & CAST SPOUT

• SINGLE HOLE, 4” CENTERSET &

  4” c/c (DUAL HOLE)

Español:

Instrucciones de instalación y mantenimiento

Français:  

Instructions pour l’installation et la maintenance

Deutsch:

Installations- und Wartungsanleitungen

中文:

安装与维护说明

ES

FR

DE

CN

EC-3103

EC-3104

EC-3105

EC-3100

EC-3101

EC-3107

Summary of Contents for ChekPoint EC-3103

Page 1: ...ach of Contract which might arise is hereby excluded and disclaimed Any implied warranties of merchantability or fitness for a particular purpose are limited to three years in duration Under no circum...

Page 2: ...2 Exploded View EC 3100...

Page 3: ...3 Exploded View EC 3101...

Page 4: ...4 Exploded View EC 3102...

Page 5: ...5 Exploded View EC 3103...

Page 6: ...6 Exploded View EC 3104...

Page 7: ...7 Exploded View EC 3105...

Page 8: ...8 Exploded View EC 3107...

Page 9: ...C 3102 EC 3103 EC 3104 Electronic Faucets 1 Aerator Vandal Resistant 2 2 GPM B 0199 08 2 Angled Sensor w Cable 017195 45 3 Inlet Hose Faucet 1 2 NPSM F x 1 4 NPSM F 016297 45 4 Electronic Module 01664...

Page 10: ...EL GRIFO A LOS PAROS DEL SUMINISTRO Important TOUT LE C BLAGE LECTRIQUE DOIT TRE INSTALL CONFORM MENT AUX CODES ET R GLEMENTATIONS NATIONAUX LOCAUX TOUTE LA PLOMBERIE DOIT TRE INSTALL E CONFORM MENT A...

Page 11: ...or Installation of Faucets 8 200mm adjustable wrench Slotted screwdriver 3 16 1 8 hex key wrench Phillips head screwdriver 1 Basin wrench Pliers Herramientas requeridas para la instalaci n de los grif...

Page 12: ...se y despu s a trav s del orificio d Mitigeur Lors de l installation du robinet avec la vanne m langeuse les instructions de la page 15 doivent tre respect es Installation des robinets de la s rie Che...

Page 13: ...Die Wassertemperatur kann ber die Anpassung des Mischventils gesteuert werden Zusammenbau der Armatur Abbildungen 2A 2B 2C 2D 2E Das Armaturenkabel und den Auslaufschaft durch die Fu dichtung und ans...

Page 14: ...inoxidable Extienda el tornillo de sujeci n 1 4 20 instalado en la parte posterior del cuerpo del grifo desatornill ndolo hacia la izquierda con una llave de cu a hexagonal de 1 8 Destornille lo sufic...

Page 15: ...rfolgt bereineStellschraube umdieArmaturinvertikalerPositionzuverankern undistAUSSCHLIESSLICHf rdieVerwendungmitEdelstahlsp lenvorgesehen Nutzen Sie das Montagelochbild oder die Fu dichtung der Armatu...

Page 16: ...und EC 3102 Abbildung 2G Hinweis DerVerdrehschutzerfolgt bereinenBolzen umdieArmaturinPositionzuverankernundistAUS SCHLIESSLICHf rdieVerwendungmitEdelstahlsp lenvorgesehen Nutzen Sie das Montagelochb...

Page 17: ...or debe suministrar las llaves de paso o comprarlas conT S Purgue cualquier residuo de las l neas de suministro Ajuste las juntas de compresi n de forma segura en las l neas de suministro Fixez le mod...

Page 18: ...te la junta de compresi n en las l neas de suministro pero sin apretar en exceso Branchements du c ble du capteur et de la conduite d arriv e d eau Figures 4 et 4A Acheminez le c ble du capteur depuis...

Page 19: ...le until all wiring has been completed This type of Transformer is designed to be plugged into a 120 VAC wall receptacle The Transformer is supplied with a 6 foot Cable Remove the rubber plug from the...

Page 20: ...capteur est sauvegard e et revient au dernier r glage lorsque l alimentation lectrique est r tablie Remarque Pour l option d alimentation du l Hydro Generator EC HYDROGEN consultez le manuel d utilisa...

Page 21: ...sed in conjunction with the optional AC adapter the faucet will automatically switch to AC power and conserve its battery power Fresh alkaline batteries should last 450 000 on off cycles CONFIGURACI N...

Page 22: ...nc le bouton marche arr t l eau s coule Apr s avoir maintenu le bouton pendant 5 7 secondes l eau cesse de couler et la DEL rouge de la lentille du capteur devient fixe 4 Rel chez le bouton marche arr...

Page 23: ...schlie end ausgehen um anzuzeigen dass der Erfassungsabstand NICHT ge ndert wurde BETRIEB 1 Halten Sie Ihre H nde unter den Auslauf Das Wasser wird so lange flie en wie sich die H nde des Benutzers in...

Page 24: ...be proteger el grifo para evitar que le salpique limpiador Los cidos y los l quidos de limpieza decolorar n o remover n la cubierta de cromo No use produc tos qu micos limpiadores o abrasivos en el le...

Page 25: ...ente al sensor AJUSTES DEL CONTROL DEL FLUJO DE AGUA Los controladores ChekPoint ofrecen opciones de ajustes preestablecidos para el control del flujo Estas opciones se obtienen mediante la configurac...

Page 26: ...nt l int rieur du module de commande ChekPoint dans un bo tier noir pr s du compartiment de piles Pour acc der aux commutateurs retirez les 4 vis et le capot arri re du module de commande R GLAGE DE L...

Page 27: ...en Die Standardeinstellung betr gt 15 Sekunden Hinweis Die nachfolgende Tabelle zeigt die Schalterstellungen die f r jeden Auto Timeout Modus erforderlich sind AUTO FLUSH Automatisches Sp len SCHALTER...

Page 28: ...FERENCE SYSTEM Sunlight or other types of lighting may interfere with the distance sensing range In this case the controller will compensate the sensing distance to a safe range temporarily The contro...

Page 29: ...ge peuvent interf rer avec la plage de d tec tion distance Dans ce cas le contr leur compense la distance de d tection en la ramenant une plage de s curit temporaire Le contr leur ajuste la distance c...

Page 30: ...impie con un pa o suave P Por qu no se corta el suministro de agua despu s de retirar las manos y colocarlas lejos del ojo electr nico R El rango del sensor podr a ser muy largo El usuario tendr que a...

Page 31: ...n electronic eye POSSIBLE CAUSE SOLUTION If red LED stays on or is flashing 1 Replace batteries and or make sure trans former is plugged in 2 If appropriate action from no 1 does not correct problem S...

Page 32: ...cies muy reflejantes luz solar etc 1 Residuos en la v lvula de solenoide no cierra apropiadamente 2 El m dulo de control est averiado cam bie el m dulo de control Flujo escaso o lento Activaci n en fa...

Page 33: ...her dass derTransformator eingesteckt ist 2 Falls die erforderliche Ma nahme Nr 1 das Problem nicht behebt Sensorbereich zu lang Waschbecken wird wahrgenommen Bereich reduzieren Sensor ist fehlerhaft...

Page 34: ...34 LED LED 1 2 1 1 2 3 1 1 2 CN...

Page 35: ...Travelers Rest SC 29690 De Veenhoeve Phone 864 834 4102 Oude Nieuwveenseweg 84 Fax 864 834 3518 2441 CW Nieuwveen E mail tsbrass tsbrass com The Netherlands EC 3130 ChekPoint Above Deck Electronic Fau...