background image

Installation and 

Maintenance

Instructions

Limited Three Year Warranty

(Commercial Applications)

 T&

S warrants to the original purchaser 

(other than for purposes of resale) that such product 
is free from defects in material and workmanship for 
a period of three (3) years from the date of purchase.  
During this three-year warranty period, if the product 
is found to be defective, T&S shall, at its options, 
repair and/or replace it.  To obtain warranty service, 
products must be returned to...

T&S Brass and Bronze Works, Inc.

Attn:  Warranty Repair Department

2 Saddleback Cove

Travelers Rest, SC  29690

  Shipping, freight, insurance, and other 
transportation charges of the product to T&S and 
the return of repaired or replaced product to the 
purchaser are the responsibility of the purchaser.  
Repair and/or replacement shall be made within a 
reasonable time after receipt by T&S of the returned 
product.  This warranty does not cover Items which 
have received secondary 

fi

 nishing or have been 

altered or modi

fi

 ed after purchase, or for defects 

caused by physical abuse to or misuse of the 
product, or shipment of the products.
  Any express warranty not provided herein, 
and any remedy for Breach of Contract which 
might arise, is hereby excluded and disclaimed.  
Any implied warranties of merchantability or 
fitness for a particular purpose are limited to 
three years in duration.  Under no circumstances 
shall T&S be liable for loss of use or any special 
consequential costs, expenses or damages.
  Some states do not allow limitations on how 
long and implied warranty lasts or the exclusion or 
limitation of incidental or consequential damages, 
so the above limitations or exclusions may not apply 
to you.  Speci

fi

 c rights under this warranty and other 

rights vary from state to state.

Attention California Residents:

         

WARNING

 This product can expose 

you to chemicals including Lead, Chromium 
(hexavalent compounds) and Phthalates (DEHP) 
which are known to the State of California 
to cause cancer and birth defects or other 

reproductive harm.

For more information go to
www.P65Warnings.ca.gov.

 P/N: 

098-020560-45 

Rev.0

 Date: 

01-03-22

 Drawn: 

TED

 Checked: DMH 

07-07-22

 Approved: JHB 

07-08-22

ECW-3150, ECW-3160 
& ECW-3170 Series

WaveCrest

ELECTRONIC SENSOR
OPERATED FAUCET:
DECK MOUNT, CAST SPOUT,
SINGLE HOLE, & 4” CENTERSET

Español:

Instrucciones de instalación y mantenimiento

Français:  

Instructions pour l’installation et la maintenance

Deutsch:

Installations- und Wartungsanleitungen

中文:

安装与维护说明

ES

FR

DE

CN

 

ECW-3172-BN

ECW-3163

ECW-3152

Summary of Contents for WaveCrest ECW-3150 Series

Page 1: ...emedy for Breach of Contract which might arise is hereby excluded and disclaimed Any implied warranties of merchantability or fitness for a particular purpose are limited to three years in duration Un...

Page 2: ...2 Exploded View ECW 3150 AND ECW 3160 SERIES 1 2 3 4 5 10 9 7 8 6...

Page 3: ...3 Exploded View ECW 3170 SERIES 1 2 3 4 5 10 9 7 8 6...

Page 4: ...45 8 A C Adapter 5EF 0002C 9 Supply Hose 9 16 24 UN Female x 1 2 NPSM 5EF 0005 10 Temperature Mixing Valve 5EF 0006 ECW 3170 Series Faucets 1 Curved Hidden Sensor with Screw 020755 45 2 0 5 GPM Hidden...

Page 5: ...L GRIFO A LOS PAROS DEL SUMINISTRO Important TOUT LE C BLAGE LECTRIQUE DOIT TRE INSTALL CONFORM MENT AUX CODES ET R GLEMENTATIONS NATIONAUX LOCAUX TOUTE LA PLOMBERIE DOIT TRE INSTALL E CONFORM MENT AU...

Page 6: ...lle o lave el lavabo Purgue la l nea L neas de suministro de agua caliente y fr a Tools Required For Installation of Faucets 8 200mm adjustable wrench Pliers 1 8 hex key wrench Phillips head screwdriv...

Page 7: ...a mezcladora Instale la unidad del grifo Figuras 2A 2B y 2C Inserte el cable del grifo y el v stago de suministro a trav s de la junta de la base y despu s a trav s del orificio de montaje del fregade...

Page 8: ...2B et 2C Ins rez le c ble du robinet et la tige du bec dans le joint de base puis au travers du trou de fixation de l vier de chirurgien ou de lavage Fixer l aide de la rondelle frein et de l crou fou...

Page 9: ...uperficie de montaje de acero inoxidable Instale el grifo alineando el pasador con el orificio peque o Ensamble con la tuerca y la arandela para fijar el grifo en su sitio Nota Si no se necesita se pu...

Page 10: ...dule as shown in Figure 3 Tighten fitting snugly BUT DO NOT OVERTIGHTEN No thread sealant is necessary Important Orient mixing valve as shown in Figure 3 Instale la unidad de la v lvula mezcladora Fig...

Page 11: ...ura en las l neas de suministro Fixez le module de commande sur le mur Installez le module de commande un endroit appropri Une fois install tous les c bles et tuyaux souples doivent avoir un peu de je...

Page 12: ...las l neas de suministro pero sin apretar en exceso Branchements du c ble du capteur et de la conduite d arriv e d eau Figure 4 Acheminez le c ble du capteur depuis la base du robinet jusqu au sommet...

Page 13: ...been completed This type of adapter is designed to be plugged into a 120 VAC wall receptacle The AC adapter is supplied with a 6 foot cable Remove the rubber plug from the DC power connector on the bo...

Page 14: ...Remarque Pour l option d alimentation Hydro Generator consultez le manuel d utilisation dans le kit EC HYDROGEN command s par ment Pour le c blage et les options de raccordement d alimentation c bl e...

Page 15: ...blink quickly then stop indicating the range setting will remain unchanged Check that the sensor lens is clean and repeat the process from step 1 Once the range is set the value is stored in the cont...

Page 16: ...valor se guardar en la memoria del controlador El rango no se borrar ni se modificar si no hay alimentaci n de CA o si se agotan las bater as FUNCIONAMIENTO Coloque las manos debajo del surtidor El ag...

Page 17: ...g es UTILISATION Placez les mains sous le bec L eau s coule jusqu ce qu une limite de temps d finie soit atteinte ou que les mains de l utilisateur soient hors de port e du capteur Remarque Led laid a...

Page 18: ...ist und wiederholen Sie den Ablauf ab Schritt 1 Wenn der Bereich eingestellt ist wird der Wert im Controllerspeicher gespeichert Der Bereich wird nicht gel scht oder ge ndert wenn der Netzstrom ausf...

Page 19: ...NETTOYAGE DU CHROME ET DES FINITIONS SP CIALES N UTILISEZ aucun produit abrasif ou chimique m me de l eau de Javel pour nettoyer les robinets car ces produits peuvent endommager le lustre et attaquer...

Page 20: ...switches SW 1 to SW 7 according to the tables below The flow control switches are located behind the battery cover just above the batteries Note SW 8 is not used PERIOD 15 seconds 30 seconds 45 secon...

Page 21: ...del interruptor requeridas para cada per odo de apagado autom tico INTERRUPTOR 1 INTERRUPTOR 7 AJUSTE DEL RETRASO DE CORTE DEL AGUA INTERRUPTORES 5 Y 6 El controlador WaveCrest ofrece cuatro per odos...

Page 22: ...de contr le du d bit sont situ s derri re le couvercle du compartiment de piles juste au dessus des piles Remarque le commutateur SW 8 n est pas utilis R GLAGE DE L ARR T AUTOMATIQUE COMMUTATEURS 1 3...

Page 23: ...s in Schalterstellung 4 zu w hlen Wenn dieser aktiviert ist sp lt der Controller die Armatur nach der letzten Verwendung alle 12 Stunden 30 Sekunden lang Ab Werk steht der Schalter auf Off Aus SW 1 SW...

Page 24: ...24 5 6 WaveCrest 1 10 15 30 1 7 15 SW 5 SW 6 1 10 15 30 SW 7 Wavecrest SW 1 SW 7 SW 8 1 3 Wavecrest 15 30 45 60 3 20 15 4 WaveCrest 4 12 30 off SW 1 SW 7 SW 4 SW 1 SW 2 SW 3 15 30 45 60 3 20 CN...

Page 25: ...recuencia de exploraci n hasta su velocidad normal de detecci n SISTEMA ANTINTERFERENCIA La luz solar u otros tipos de iluminaci n pueden interferir con el rango de detecci n de la distancia El sensor...

Page 26: ...ean Use only mild soaps and water Wipe with a soft cloth Preguntas y respuestas P Puede operarse el grifo manualmente sin usar el ojo electr nico R S Presione el bot n azul su ltelo y el agua comenzar...

Page 27: ...t can contribute to the range for example bright lights highly reflective surfaces sunlight etc 1 Clean sensor lens 2 Range too long decrease detection zone Continues to Run Even after power to faucet...

Page 28: ...l problema El rango del sensor es muy largo detecta el lavabo Reduzca el rango El detector est averiado se debe cambiar el m dulo del sensor 1 Revise los paros del suministro bralos si est n cerrados...

Page 29: ...toyez la lentille du capteur 2 La port e est trop longue r duisez la zone de d tection L eau continue s couler M me apr s la mise hors tension du robinet 1 Des d bris bloquent l lectrovanne qui ne se...

Page 30: ...ie zur Reichweite beitragen k nnen z B helle Lichter stark reflektierende Oberfl chen Sonnenlicht usw 1 Reinigen Sie die Sensorlinse 2 Reichweite zu lang Erfassungsbereich verringern L uft weiter Selb...

Page 31: ...avelers Rest SC 29690 De Veenhoeve Phone 864 834 4102 Oude Nieuwveenseweg 84 Fax 864 834 3518 2441 CW Nieuwveen E mail tsbrass tsbrass com The Netherlands EC 3130 ChekPoint Above Deck Electronic Fauce...

Reviews: