background image

www.targetti.com

cod. 2EA7CS00_103

Targetti Sankey S.p.A. Via Pratese, 164 50145 Florence Italy

ZEDGE line
ZEDGE line opal

RG1 secondo norma IEC/TR 62778:2014 / RG1 in accordance with IEC/TR 62778:2014

RG1 selon la norme IEC/TR 62778:2014 / RG1 nach der norm IEC/TR 62778:2014

RG1 enlight IEC/TR 62778:2014  / RG1 volgens IEC/TR 62778:2014

RG1 de acordo com norma IEC/TR 62778:2014

+35°C

-25°C

In caso di dubbi sulla simbologia,
riferirsi al catalogo o al sito web.

If in doubt about the symbols refer
to catalog or website

IK10

0,7Kg

6W Sorgente Led / Led source
7W Apparecchio / Fixture

COD. 1E3441 / 1E3445 / 1E3446 / 1E3763
COD. 1E3511 / 1E3513 / 1E3515 / 1E3765

220/240V
50/60Hz

IP66

III

24Vdc

0,7Kg

- 1 -

8W Sorgente Led / Led source
9W Apparecchio / Fixture

COD. 1E3442 / 1E3443
COD. 1E3444 / 1E3764

24Vdc

220/240V
50/60Hz

EL-DA

6W Sorgente Led / Led source
8W Apparecchio / Fixture

COD. 1E3512 / 1E3514
COD. 1E3516 / 1E3766

220/240V
50/60Hz

EL-DA

304

6

4

52

OPAL

6

4

304

misure in (mm)

measures (mm)

IK07

Attenzione! Per gli apparecchi equipaggiati con sistema DALI, tutti i cavi, le connessioni e le attrezzature utilizzate
devono essere conformi e adeguate alla relativa tensione di rete; Il segnale DALI potrebbe non essere trasmesso
con una bassissima tensione di sicurezza (SELV).
Sono disponibili all’indirizzo www.digitalilluminationinterface.org tutte le informazioni generali sul sistema DALI.

Warning! For luminaires equipped with DALI system, all cables, connections and equipment used must comply and
adapt to the relative mains voltage; The DALI signal may not be transmitted with a very low safety voltage (SELV).
All general information on the DALI system are available at www.digitalilluminationinterface.org.

Summary of Contents for ZEDGE

Page 1: ...1E3442 1E3443 COD 1E3444 1E3764 24Vdc 220 240V 50 60Hz EL DA 6W Sorgente Led Led source 8W Apparecchio Fixture COD 1E3512 1E3514 COD 1E3516 1E3766 220 240V 50 60Hz EL DA 304 64 52 OPAL 64 304 misure...

Page 2: ...en du syst me Bitte bergeben Sie diese Anleitung dem Verantwortlichen f r die Wartung der Beleuchtungsanlage L mna en kopia av dessa instruktioner till underh llschefen Entregar una copia de estas ins...

Page 3: ...podr a estar disponible una versi n m s actualizada del presente manual A PRODUCTS www targetti com I GB F D S E RU www targetti Zur Beachtung Bitte berpr fen Sie die Website www targetti com nach ei...

Page 4: ...VO 3x1 5mm MAX H05RN RF 7mm 12mm MAX USE CABLE 3x1 5mm MAX H07RN RF 7mm 11 5mm MAX DALI USARE CAVO 5x1mm MAX H05RN F 7mm 11 5mm MAX USE CABLE 5x1mm MAX H07RN F 7mm 11 5mm MAX COD 1E3305 B b1 b2 b3 230...

Page 5: ...DRIVER N MAX APPARECCHI ALIMENTABILI MAX FIXTUREFOR EACH DRIVER IP20 1T3726 5 IP67 1E3179 1 IP67 1T3586 8 IP67 1T3587 10 IP67 1T3588 20 IP68 1E0993 2 DRIVER 24V DIMMER 1T6581 DA DA 24Vdc L N 230V DAL...

Page 6: ...www targetti com TARGETTI SANKEY S p A Via Pratese n 164 Florence Italy C INSTALLAZIONE TIPO B INSTALLATION TYPE B INSTALLAZIONE TIPO A INSTALLATION TYPE A 6...

Page 7: ...1T7003 ZEDGE LINE L Marrone Brown DA DA N Blu Blue Grigio Grey Nero Black Terra Ground Marrone Brown Blu Blue 220V DA 24Vdc L Marrone Brown N Blu Blue Terra Ground 220V EL 5 30mm MIN MAX CONNESSIONE...

Page 8: ...taly 8 OUT IN OUT OUT 24V EL OUT OUT SCHEMA DI COLLEGAMENTO ALIMENTAZIONE E LOOPING WIRING SCHEME FOR MAIN AND LOOPING COD 1E2494 COD 1E2494 COD 1E2769 COLLEGAMENTO ESTERNO AL PRODOTTO WIRING EXTERNAL...

Reviews: