1
DA-60
MK
II
QUICK TIPS
Note:
Whenever this document directs you to “Hold SHIFT and press MENU
▲
or
▼
” to
arrive at a particular screen, you can use the alternate procedure of “Hold SHIFT while
rotating the DATA DIAL.” While both methods accomplish the same task, you may find
rotating the Data Dial preferable.
After changing system parameters in the various edit screens, pressing either MENU
▲
or
▼
will exit you back to the main screen.
AUTO CUE
(Cue to Modulation)
1) This function requires use of the Memory Start feature, and its performance is
directly affected by the Auto Cue Sensitivity level
AUTO CUE SENSITIVITY LEVEL
1) Hold SHIFT and press MENU
▲
or
▼
until you arrive at screen #6 "AtcuE"
2) Press DATA, current parameter value will blink (Memory Start Standby mode must
be disengaged)
3) Rotate DATA DIAL either clockwise or counter clockwise until desired value is
displayed
4) Press SET to confirm new parameter value
CAPTURE OFFSET
1) Hold SHIFT and Press MENU
▲
or
▼
until you arrive at screen display “-tc-cLoSE”
(if display reads “oPEn”, proceed to step 3)
2) Press DATA (“cLoSE” will blink), rotate DATA DIAL to “oPEn” - press SET
3) Press MENU
▲
or
▼
until "
■
CHASE OFFSET" appears in the upper right display
4) While holding SET, press CHASE - the smaller of the two Time Code displays will
be the current offset value
Note: It is assumed that Time Code is being fed to the DA-60
MK
II from an external
device.
To Trim or Clear the Offset:
5) Press MENU
▲
or
▼
and select "
■
CHASE OFFSET"
6) Press DATA - the "hour" digits of the offset screen will blink and successive
presses of DATA enable you to cycle from "minutes" to "seconds" to "frames" to
"sub frames" and back to "hour"
7) Enter the desired value using the DATA DIAL and DATA key - upon completion,
press SET