©Copyright Task Force Tips LLC 2003-2020
1
LIU-030 August 24, 2020 Rev10
TASK FORCE TIPS LLC
MADE IN USA · tft.com
3701 Innovation Way, Valparaiso, IN 46383-9327 USA
800-348-2686 · 219-462-6161 · Fax 219-464-7155
INSTRUCTIONS FOR OPERATION, AND MAINTENANCE
PRO/pak
®
Portable Multi-Purpose Foam System
WARNING
Understand manual before use. Operation of this device without understanding the manual and
receiving proper training is a misuse of this equipment. Obtain safety information at tft.com/serial-
number.
This equipment is intended for use by trained and qualified emergency services personnel for
firefighting. All personnel using this equipment shall have completed a course of education
approved by the Authority Having Jurisdiction (AHJ).
This instruction manual is intended to familiarize firefighters and maintenance personnel with the
operation, servicing, and safety procedures associated with this product. This manual should be
kept available to all operating and maintenance personnel.
k
a
p
/
O
R
P
k
a
p
/
O
R
P
PORTABLE MULTI PURPOSE FOAM SYSTEM
PATENT PENDING ó MODEL UM12
RATED FLOW
12 GPM at 100 PSI
45 L/MIN at 7.0 BAR
Minimum Operating Condition
7 GPM at 40 PSI
30 L/MIN at 3 BAR
Maximum Operating Condition
27 GPM at 500 PSI
100 L/MIN at 40 BAR
ADDITIVE SETTINGS
CLASS A RANGE: OFF, 0.1% TO 1.0% continuously adjustable
CLASS B RANGE: OFF, 1%, 3%, 6%