Product information  

combined device with  

binary input / output, single 

BRE2-EB

 

Safety instructions 

General safety regulations

 

!

 

Attention! Mounting, installation, commissioning and repair of electronic devices have 
to be carried out only by qualified electricians. The standards for the prevention of ac-
cidents must be observed. 

 
When working in systems with mains connection 230 V, the safety regulations according to 
DIN VDE 0100 must be observed. 
 
When installing TCS:BUS

® 

systems, the general safety regulations for telecommunication 

systems according to VDE 0800 must be observed. Inter alia: 

  separated conduit of heavy and low current lines, 

  minimum distance of 10 cm in case of common conduit, 

  use of separators between heavy and low current lines within shared cable ducts, 

  use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter, 

  existing lines (modernisation) with deviating cross-sections can be used in compliance 

with the loop resistance. 

 

Attention! 

  The ingress of liquids or electronically conductive parts can cause short-circuits, fire or 

an electronic shock. Thus, provide water or other liquids from entering the device. Fur-
ther provide electronically conductive parts from entering the device. 

 

Installation 

– protective measures  

  Outside the device, an easy accessible separator to disconnect the power supply must 

be provided. 

  An overcurrent protective device must be installed upstream. 

  The device must be installed in such way, that the user has no direct access to the 

mains connection terminal after the installation.  

  With suitable measures to protect against lightning, it has to be ensured that a voltage 

of each 32 V DC is not exceeded at the TCS:BUS wires a, b and P. 

  The device corresponds to the overvoltage category II. 

Summary of Contents for BRE2-EB

Page 1: ...tors between heavy and low current lines within shared cable ducts use of standard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance Attention The ingress of liquids or electronically conductive parts can cause short circuits fire or an electronic shock Thus provide water or other liqu...

Page 2: ...E2 EB is suitable to execute switching and detection functions in TCS BUS sys tems To be built in into flush mounted sockets Suitable for 3 wire connection a b and P 2 wire connection with max of 3 pieces BRE2 EB within the TCS BUS sys tem Short description Basic functions output potential free for switching functions to trigger the switch time by pressing bell buttons of any front door station fl...

Page 3: ...voice connection second serial number control functions and front door calls of 10 further serial numbers switch ON OFF function switch ON OVER function linkage of several relay switch functions setting a programming lock Function of the input as opener to create any TCS BUS protocol open the device s output Connecting the lines Connection lines per terminal TCS BUS input terminals 0 12 0 5 mm2 di...

Page 4: ... blinks for 30 s press as long as Prog2 tone light switch tone and ring tone sound at the front door station release shortly LED press is ON output is allocated to a bell button Programming mode of the system is switched OFF Delete the allocation to a bell button shortly LED press blinks press until the delete tone sounds release shortly LED press is ON Programming mode of the system is switched O...

Page 5: ... release the LED lights up press door opener or press floor push button or free BUS actions by entry via Service Device TCSK 01 press until the release LED lights up shortly LED OFF execute required BUS action input is allocated to BUS actions Reload factory setting2 switch time of the output 1 s input sends door release protocol AS 0 BRE2 press until release the LED is ON press until the LED rele...

Page 6: ...ormation on disposal The adjoining symbol shows that the device has to be disposed separately from domestic waste The material used are recycable Please do help protecting our environment and dispose the device via a collection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics ...

Page 7: ...ct to technical changes FAX 49 0 41 94 9 88 129 PI_bre2eb_uk 1 A Warranty We offer a simplified processing in case of warranty for electricians Please note our conditions of sale and delivery download from www tcsag de down loads trade information Please contact the TCS HOTLINE ...

Page 8: ... Subject to technical changes FAX 49 0 41 94 9 88 129 PI_bre2eb_uk 1 A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Phone 49 0 3933 879910 FAX 49 0 3933 879911 www tcsag de ...

Reviews: