background image

 

1 of 4 

© 2020 TE Connectivity family of companies 
All Rights Reserved 
| Indicates Change 

*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.  Other logos, product, and/or company names may be trademarks of their respective owners. 

Instruction sheet 

This controlled document is subject to change. 

For latest revision and Regional Customer Service, visit our website at www.te.com  
PRODUCT INFORMATION 1-800-522-6752 
 

408-78067 

1 MAY 2020  Rev A

DYNAMIC CONNECTOR D5900 SERIES 

1. 

INTRODUCTION 

This Instruction Sheet describes the operation method of DYNAMIC CONNECTOR D5900 series. 
Please refer to product standard 108-140022 for a detailed product performance of the connector. 

2. 

COMPOSITION 

DYNAMIC CONNECTOR D5900 is composed of the Receptacle assembly and the Header Connector. 
The circuit number is marked to the Receptacle assembly for correct installation.  

3. 

RECEPTACLE ASSEMBLY 

3.1. 

Receptacle assembly with spring opener (2260828-1) 

3.1.1  Insert the hook head of spring opener (2260828-1) into a square hole on the wire insertion side 

of the receptacle assembly. 

3.1.2  Push the lever of the spring opener (2260828-1) with thumb at illustrated direction in Fig. 1 until 

the rib on the opener enters the hole firmly. 

*Operate the spring opener with receptacle assembly unmating with header connector, or the 
header connector and PCB would be damaged.  

 

 

Fig. 1 

 

 

 

 

 

 

 

 

 

 

3.1.2 

3.1.1 

Reviews: