background image

TECElux

Sanitary systems

TECHNICAL GUIDELINES

Summary of Contents for sen-Touch 9650002

Page 1: ...TECElux Sanitary systems TECHNICAL GUIDELINES...

Page 2: ...1 2 TECElux...

Page 3: ...lation in floor to ceiling metal stud wall with UA profiles 1 18 Installation in a wooden stud wall 1 19 Attaching individual modules to the floor 1 20 Connecting the drain bend 1 20 Panel facing and...

Page 4: ...ceramic Design With its simple aesthetics TECElux blends in with the archi tecture of any bathroom The terminal s large glass surface consists of two parts that give the appearance of a single unit Th...

Page 5: ...TECElux enables you to adjust the height of the toilet ceramic at any time even after the module has been installed The ceramic does not have to be removed to do this The height can be continuously ad...

Page 6: ...0109 TECEone s Order no 9650110 A TECElux module B Upper flush plate C Lower attachment facing White buttons w Order no 9650000 Black buttons s Order no 9650005 Bright chrome buttons w Order no 965000...

Page 7: ...connection dimension 180 mm x TOTO Neorest AC TOTO Neorest EW x x TOTO Washlet CF TOTO Washlet EK with side connections TCF6632G NW1 TOTO Washlet GL with side connections TCF6532G NW1 TOTO Washlet Gi...

Page 8: ...rofil rail Toilet drain bend with DN 90 100 adapter Clearly visible meter marking sticker TECElux 100 module With TECE concealed cistern and dual flush technology The flush is actuated mechanically by...

Page 9: ...s standing in the flush pipe of some ceramics with a higher sitting position or higher flushing rim resulting in the bowl becoming partially or completely full The following table lists ceramics for w...

Page 10: ...material Incl plug in power pack 230 V connection voltage with dual flush actuation motor Dimensions 430 x 555 x 16 mm Design in white glass Order no 9650002 Design in black glass Order no 9650003 Lo...

Page 11: ...430 x 445 x 16 mm Design in white glass Order no 9650103 Design in black glass Order no 9650107 Lower glass facing for Geberit Aquaclean Sela shower toilet Lower toilet glass facing for combination wi...

Page 12: ...connection for odour extraction Drain valve Order no 9660000 Connection set for shower toilet Connection set comprising long reinforced hose with connection for TOTO Neorest TOTO Washlet and V B ViCl...

Page 13: ...l Installation in a TECEprofil pre wall The simple mounting technology enables you to work swiftly and reliably TECElux modules can be integrated quickly and safely into a TECEprofil wall in a few sim...

Page 14: ...nforced at the mount ing points The procedure should be followed in line with the dry wall construction Take into account the installation instructions for the dry wall system used Individual mounting...

Page 15: ...en tile pattern Universal attachment 9380002 Adjustment range of the height adjustable module attachment 130 200 mm When using the TECElux 100 without barriers in front of a solid wall an additional m...

Page 16: ...l wall at an angle of 45 In the process only one side is screwed into the structure Two angle brackets are included for mounting the panel facing Thanks to the small side length of the attachment stru...

Page 17: ...in paral lel A storage surface can be created with two TECEprofil panels an angle bracket and a corner attachment The corner installation requires very little space The mounting set has a side length...

Page 18: ...nstallation instructions for the dry wall system used Installation in floor to ceiling metal stud wall with UA profiles Installation in a floor to ceiling UA profile metal stud wall If particularly wi...

Page 19: ...installed in wooden stud walls in accordance with DIN 4103 1 For this purpose the frame can be mounted using special wood screws order number 9380005 on the vertical struts Module attachment during in...

Page 20: ...with m Lift function TECElux 200 and 400 The flexible drain bend can be installed horizontally on both sides or vertically downwards Horizontal installation of the flexible drain bend TECElux 200 and...

Page 21: ...mensions of bare wall protection or wall recess Cutting out the wall recess To ensure height adjustment of both TECElux 200 400 modules the module frames should not be drilled through in certain areas...

Page 22: ...ure that the wall covering is applied seamlessly right up to the bare wall protection Applying the wall covering When tiling the floor make sure that the plinth height is maximum 50 mm otherwise the l...

Page 23: ...ished floor surface area and the horizontal surface area at the height of the highest permanently attached shower head or water outlet or the surface area up to 225 cm vertically above the finished fl...

Page 24: ...1 24 Installing a TECElux module in safety zone 2 with connection set Installing a TECElux module outside the safety zone with surface mounted sockets TECElux Shell installation TECElux...

Page 25: ...lve with TECEone For the corner valves we recommend the position shown at the top as in this way accessibility can be provided by lifting off the upper flush plate The length of the two reinforced hos...

Page 26: ...for standard toilet Remove the bare wall protection Remove the attachment nuts x 4 on the depth adjustment securing the threaded rods at the back in the process Adjust the lower glass facing at the t...

Page 27: ...t and if not already carried out at the factory insert both glass protection caps Cut the toilet connection set to a suitable length and insert Mount the sound insulation strips on the ceramic Align t...

Page 28: ...e bare wall protection Remove the attachment nuts x 4 on the depth adjustment securing the threaded rods at the back in the process Adjust the lower glass facing at the top and bottom so that it fits...

Page 29: ...he cistern Sufficiently flush out the connecting pipe Remove the reinforced hose and replace it with the replacement reinforced hose with the water connection for the shower toilet or shower toilet se...

Page 30: ...rit AquaClean 8000 8000 plus order number 9650101 106 After the preparation phase see assembly steps 1 to 14 at the start of this section the glass facing can actually be installed Mount the lower gla...

Page 31: ...TOTO Washlet and Geberit AquaClean 5000 5000 plus order number 9650102 After the preparation phase see assembly steps 1 to 14 at the start of this section the glass facing can actually be installed M...

Page 32: ...mber 9650103 107 After the preparation phase see assembly steps 1 to 14 at the start of this section the glass facing can actually be installed Mount the lower glass attachment facing and if not alrea...

Page 33: ...ve C Sufficiently flush out the reinforced hose Mount the Duravit electronic connection box following the Duravit installation instructions or V B connector plug following the V B installation instruc...

Page 34: ...he lower glass attachment facing Guide the reinforced hose and power cable through the sewage water connection or side opening in the glass attachment facing Cut the toilet connection set to a suitabl...

Page 35: ...sibility can be provided by lifting off the upper flush plate After the preparation phase see assembly steps 1 to 10 at the start of this section the glass facing can actually be installed PWC kalt co...

Page 36: ...t Mount the sound insulation strips on the ceramic Connect the reinforced hoses to the TECEone connection hoses All the other assembly steps are described in detail in the instructions of the respecti...

Page 37: ...ide retainers B must first be removed The height can then be adjusted via the adjusting screw For quick adjustment the ceramic can also be raised slightly Find adjustment is then carried out using the...

Page 38: ...g pipe and screw on to the filler valve Cut the actuating rod to a suitable length Screw in the actuating rods 4 mm in front of the wall surface Screw in both magnetic holders 10 mm in front of the wa...

Page 39: ...n test on the flushing system Fill the gap between the ceramic and the glass facing with permanently elastic joint sealant Upper glass facing with electronic actuation 3 4 Remove the splash guard suff...

Page 40: ...e of delivery of the No conversion of drain valve required 7 10 mm Screw in both magnetic holders 10 mm in front of the wall surface 8 9 Insert the upper flush plate into the supports and lift up 10 A...

Page 41: ...g in contacts grey actuation motor black ceramic Air odour extraction if there is one red plug in power pack 12 Plug the plug in power pack into the socket 13 Carry out a function test on the flushing...

Page 42: ...ly factory setting function only for exhibitions Procedure This is how to program the sen Touch electronics Touch the large or small touch field with your hand Programming mode starts after 10 seconds...

Page 43: ...utmost care The correctness of the data presented cannot be guaranteed however TECE assumes no liability for damages resulting from the use of this information Text and images are protected by copyrig...

Page 44: ...TECE GmbH P 49 25 72 9 28 999 international business tece com www tece com More information on www tece com 04 2018...

Reviews: