background image

 

TechMaster 

Lock system for safes 

 

 

 

 
 
 

PROGRAMMING AND OPERATING 

INSTRUCTIONS 

 
 

 

Summary of Contents for T9530

Page 1: ...TechMaster Lock system for safes PROGRAMMING AND OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...6 4 Change Code Menu 17 4 1 Change Users and OVR Users Code 17 4 2 Change Manager Code 17 4 3 Change OVR Manager Code 18 4 4 Change Master Code 18 5 Time Menu 19 5 1 Opening Extension 19 5 2 Immediate...

Page 4: ...ower off after 30 seconds of non operation TechMaster opening and administration codes Every user Manager Standard user or Override can be a numerical code or a numerical code Dallas key Master code c...

Page 5: ...be set on each lock Delay Period 0 99 minutes Open Period 1 19 minutes Five Time Delays can run at once Dallas keys Can be set on each lock requires code and key Available for all Manager and Users no...

Page 6: ...k after opening with time delay Important notes Simple trivial codes which could be easily guessed 1 2 3 4 5 6 have to be prevented Never remove lock cover this voids the warranty 1 Master Menu Power...

Page 7: ...ress Press LCD will display the message ADD Press LCD will display the current day of the week hh mm DAY hh mm The first is Opening time and the second is Closing time Enter Opening and Closing time t...

Page 8: ...Press to delete the set values LCD will display the message DELETE Press to confirm or press to exit At the end of the list press END OF LIST Time Lock Standard week is an Opening Time Period the safe...

Page 9: ...fter that date If a value for Year is not set this Special Event will repeat every year To cancel entered values press Repeat this procedure for every Special Event Special Events are Closing Periods...

Page 10: ...DD MM YY hh mm DD MM YY hh mm The first one is the opening time and date and the second one is the closing time and date Enter Opening and Closing time and date then press to confirm If a value for Y...

Page 11: ...the message DELETE Press to delete the LCD values or press to exit At the end of the list press END OF LIST 1 3 PC Link Use this function to start the communication between TechMaster and PC audit se...

Page 12: ...o enable or disable the use of Dynamic Codes on the lock Power up TechMaster and access the Master Menu Press four times LCD will display the message DYNAMIC CODES Press LCD will display the actual st...

Page 13: ...s or enter a User ID to select a user 01 02 03 04 Press LCD will display the message 01 T1 DISABLE Press to confirm or press to install delete disable enable and press to confirm To skip to the follow...

Page 14: ...3 Variable Time Delay Depending on lock configuration this menu could not be available Power up TechMaster and access the Manager Menu Press two times LCD will display the message VARIABLE TIME DELAY...

Page 15: ...DD 2 3 2 Variable Time Delay Verify or Delete Use this function to verify or delete Variable Time Delay values Power up TechMaster and access the Variable Time Delay menu Press Press LCD will display...

Page 16: ...this menu inside Master menu or inside Manager menu Use this function to install delete enable or disable or disable OVR Users on the lock Power up TechMaster and access the OVR Manager Menu Press LC...

Page 17: ...to change Users and OVR Users code Always perform this operation with the door opened Power up TechMaster System and access the Change Code Menu Press LCD will display the message CHANGE USER CODE Pr...

Page 18: ...times LCD will display the message CHANGE OVR MANAGER CODE Press to confirm LCD will display the message OLD CODE X X X X X X Enter the old code LCD will display the message NEW CODE X X X X X X Ente...

Page 19: ...USER CODE X X X X X X X X If you hold the Manager code press LCD will display the message MANAGER CODE X X X X X X Enter the User code or enter the Manager code LCD will display the message OPENING EX...

Page 20: ...IMMEDIATE TIME LOCK Press If Time lock period is programmed LCD will display the next Time Lock opening period CLOSED UNTIL 14 09 08 00 Press to confirm If you want to enter different values enter new...

Page 21: ...de or press if the Master code is the default code 1 2 3 4 5 6 7 8 LCD will display the message LOCK X INSTALLED 6 2 Remove Locks Use this function to remove locks from TechMaster keypad Power up Tech...

Page 22: ...e message LCD CONTRAST Press LCD will display the message ADJUST CONTRAST X Enter a contrast level between 1 and 9 and press to confirm 6 4 Language Use this function to set LCD language Power up Tech...

Page 23: ...splay the message SYSTEM INFO Press to check information 7 Opening the Locks 7 1 Users or OVR Users Opening the lock without Time Delay Power up TechMaster and select the lock when two or more locks a...

Page 24: ...USER CODE X X X X X X X X Enter a valid user code and insert the Dallas key if set up LCD will display the message OPEN Invalid code will prompt LCD to display the message WRONG CODE Open the door wi...

Page 25: ...up or OVR Manager code and insert the Dallas key if set up LCD will display Time Delay counting time TIME DELAY 00 59 Invalid code will prompt LCD to display the message WRONG CODE To abort Time Delay...

Page 26: ...he LCD to display the message WRONG DYNAMIC CODE If the Dynamic Code is entered 30 minutes before his activation time LCD will display the message DYNAMIC CODE BROUGHT FORWARD If the Dynamic Code is e...

Page 27: ...activation time LCD will display the message DYNAMIC CODE EXPIRED Dynamic Codes must be used respecting the sequence of activation time in which they have been created by the software otherwise the l...

Page 28: ...prompt LCD to display the message WRONG CODE To abort Time Delay press and then to confirm STOP DELAY COUNTING To operate with other locks press during Time Delay counting time and then press again S...

Page 29: ...ic Codes Expiry from 1 to 240 months option If this option is set LCD will display a warning message when a valid code is entered starting from one week before the expiry date CODE WILL EXPIRE IN 7 DA...

Page 30: ...chMaster Enter a valid user code LCD will display time delay counting TIME DELAY 00 59 After Time Delay LCD will display open window counting OPEN WINDOW 00 01 Enter a valid user code LCD will display...

Page 31: ...4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 1 EN 61000 6 3 EN 60335 1 EN55022 EN55024 EN50130 4 We the Company Tecnosicurezza s r l declare herewith on our own responsability that the above m...

Page 32: ...trical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking displayed on the product or its literature indicates that it sho...