background image

Product manual

 Cello 4S data logger

C

        Copyright Technolog Ltd. 2017. All rights reserved.
        Information contained in this document subject to
change without prior notice.

Sheet 1   of 43

Technolog Limited,
Ravenstor Road,
Wirksworth,
DE4 4FY,
United Kingdom

T: +44 (0) 1629 823611
E: techsupport@technolog.com
www.technolog.com

DMR No.: 7504

2099PM9000  Rev. B

Summary of Contents for Cello 4S

Page 1: ...rights reserved Information contained in this document subject to change without prior notice Sheet 1 of 43 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E tec...

Page 2: ...andard connections Port 3 Two channel input analogue and or digital connection 20 Standard connections Port 3 Local communications COMMs 21 Standard connections Port 4 Internal pressure sensor 22 Stan...

Page 3: ...tories check with your local Technolog representative Remote cellular telecommunications network communication 2G GSM850 EGSM900 DCS1800 PCS1900 3G UMTS1900 band 2 UMTS850 band 5 or UMTS2100 band 1 UM...

Page 4: ...range 20 C to 50 C 4 F to 122 F Cello 4S having an ingress protection rating of IP68 1m or equivalent depth for 48 hours is suitable for use on sites likely to flood with fresh un contaminated cold w...

Page 5: ...are potentially a severe burn hazard The cell contents are harmful by ingestion inhalation or skin contact cause headache dizziness nausea and prolonged exposure may result in liver damage whilst the...

Page 6: ...ment subject to change without prior notice Sheet 6 of 43 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E techsupport technolog com www technolog com DMR No 750...

Page 7: ...should also be positioned such that exposure of users and or bystanders to the potentially dangerous radio frequencies RF generated by the equipment are kept below recommended levels for further deta...

Page 8: ...such that exposure of users and or bystanders to the potentially dangerous radio frequencies RF generated by the equipment are kept below recommended levels for further details refer to Technolog Dec...

Page 9: ...wide with a central orifice of not less than 130mm and there must be not less than 30mm between the top edge of the rim and the underside of the boundary box lid To maximise the remote communications...

Page 10: ...ort 1 Optional local communications COMMs connection Port 2 External DC power source connection battery pack and or DC power supply Port 3 Optional two channel input analogue or digital connection con...

Page 11: ...interrogation and or setup and or data download of the Cello 4S using a PC laptop tablet or similar with either an RS232 or serial USB communications port Communications are full duplex asynchronous w...

Page 12: ...atively a dc supply capable of supplying 4 5 to 15Vdc at 60mA always check the EXT PWR voltage and current ratings stated on the main product label The following Technolog 3 6V lithium primary non rec...

Page 13: ...h closure or logic pulses maximum frequency 16kHz programmable sampling period of 1 to 250 seconds independent of recording rate Analogue 0 2 5Vdc 0 01V resolution Notes For digital inputs 0 0 5Vdc an...

Page 14: ...ncluding high resolution Hi Res state count Input Digital frequency Input Digital open collector open FET V GPi2 or GPi3 GND 0V Pulses counted over and recorded at pre set intervals GPi2 or GPi3 GND 0...

Page 15: ...xample 1 for an input voltage of 0 to 18V Applying Rule 1 let R2 330R Applying Rule 2 R1 330 2 5 18 330 2k5 0 1 precision 2k1 is the closest precision value Applying these rules may take some practice...

Page 16: ...t technolog com www technolog com DMR No 7504 2099PM9000 Rev B Standard connections Port 3 Two signal input analogue and or digital connection continued Input Analogue 4 to 20mA current loop powered V...

Page 17: ...any input can be allocated to any channel Single volt free pulse head connection Dual volt free pulse head connections V GPi2 or GPi3 GND 0V Pulse head 1 Frequency 16kHz Max V GPi2 GND 0V Pulse head 1...

Page 18: ...4S Aquamag Note where supplied terminated with a 12 way Mil Spec connector Technolog interface cable CBL225 is available for direct connection to Cello 4S V GPi2 or GPi3 GND 0V FWD flow DRAIN GND Ora...

Page 19: ...pre wired by Technolog for direct connection to Cello 4S ref CBL226 V GPi2 or GPi3 GND 0V FLOW GND Green Black MeterMate 1 V GPi2 GND 0V FLOW GND Green Black MeterMate 2 V GPi3 GND 0V FLOW GND Green...

Page 20: ...setup and or data download of the Cello 4S using a PC laptop tablet or similar with either an RS232 or serial USB communications part Communications are full duplex asynchronous with a data transmissi...

Page 21: ...for details flats 17mm A F are provided to allow the pressure connection to be tightened using a spanner or similar tool Each manifold is supplied with a removable quick release coupling plug dn 5mm...

Page 22: ...uivalent provided with 2 5m length of cable and an integral quick coupling plug dn 5mm pressure fitting for attachment to a mating pressure fitting The above sensors are suitable for the pressure meas...

Page 23: ...contacts or logic pulses Count pulses counted over and recorded at pre set intervals State Tamper status and time of state change recorded Event time of pulse recorded Frequency switch closure or logi...

Page 24: ...file Each Output can supply 80mA of current at 12V and this must be considered where they are required to supply power for externally connected equipment The VO output termination provides a constant...

Page 25: ...ls V GPi1 to GPi8 GND 0V 3V3 Output 1 or 2 12V or 3V3 VO 3V3 3V3 12V Pulses counted over and recorded at pre set intervals Internal pull up resistor s enabled in configuration file Internal debounce c...

Page 26: ...e rules may take some practice Example 2 for an input voltage of 0 to 10V Applying Rule 1 let R2 330R Applying Rule 2 R1 1k3 0 1 precision 0 to 2 5Vdc V GPi1 to GPi8 GND 0V 3V3 Output 1 or 2 12V or 3V...

Page 27: ...on of this document 2 Output 1 and Output 2 are each capable of powering a maximum of 4x 4 20mA loops 4 to 20mA V GPi1 to GPi8 GND 0V 3V3 Output 1 or 2 12V or 3V3 VO 3V3 3V3 12V V GPi1 to GPi8 GND 0V...

Page 28: ...t partial support for the variable V format Neptune E Coder 6 digit E Coder 8 digit Kent Elster K string format Typical connections Note Refer also to the Standard connections Channel mapping channel...

Page 29: ...xternal antenna specifically approved by Technolog for use with Cello 4S and taking into account the intended application site should be connected Contact Technolog for further information and details...

Page 30: ...vailable contact Technolog for details flats 17mm A F are provided to allow the pressure connection to be tightened using a spanner or similar tool Each manifold is supplied with a removable quick rel...

Page 31: ...ressure fitting for attachment to a mating pressure fitting The above sensors are suitable for the pressure measurement of dry or wet media compatible with stainless steel and provide programmable res...

Page 32: ...re set intervals Digital Tamper status event event time supported Digital Frequency switch closure or logic pulses maximum frequency 16kHz programmable sampling period of 1 to 250 seconds independent...

Page 33: ...e optional open face sealed polarised keyed M12 A coded encoder female connector is provided for the attachment of external equipment with an encoder interface the following encoder protocols are supp...

Page 34: ...itted in conjunction with the Universal eight signal input then one of the channels is allocated to the pressure thereby reducing the number of GPi inputs from eight to seven Additionally each pressur...

Page 35: ...ver in addition any physical input can be copied or shadowed to more than one channel with each channel then being treated differently For example Forward and reverse signals FR mode Flow and directio...

Page 36: ...ear of manufacture WW Week of manufacture NNNNN Product number 3 Port 3 option Marking Meaning 3 2CH Two signal input Local COMMs connection 4 Port 4 option Marking Meaning 4 100m Internal pressure se...

Page 37: ...ginning of this document for further details Where a tamper evident label is fitted to the unit it must first be ensured that the necessary permissions are in place to allow entry before proceeding Be...

Page 38: ...there are no finger prints or other marks on its contacts use a clean and dry lint free cloth to remove Step 5 Noting orientation refit the SIM into the holder by carefully pushing it down until the l...

Page 39: ...ting the new battery pack ensure it has a terminal voltage 3 6V only a battery pack of the type indicated below and specifically approved for use with Cello 4S may be fitted Step 5 Refit the lid as in...

Page 40: ...onfigure Output 1 Output 2 and the separate 100 precision resistors required for 4 20mA current measurement on each of the eight General Purpose inputs GPis Note The required settings for the dip swit...

Page 41: ...input 4 20mA dip switch setting options continued JP5 8 JP5 1 JP2 8 JP2 1 Function Setting JP5 8 JP5 7 JP5 6 JP5 5 JP5 4 JP5 3 JP5 2 JP5 1 Output 1 3V3 68k OFF OFF ON ON Output 1 12V ON ON OFF OFF Ou...

Page 42: ...ntation correctly and carefully align the lid with the base then after ensuring all cables are inside and won t be trapped lower the lid on the base Step 2 Ensure the lid seal is clean un damaged and...

Page 43: ...es the Wi Fi build option check the Type code on the main product label if it indicates WF then that product does feature Wi Fi functionality Be aware that depending on territory due to regulatory com...

Reviews: