Summary of Contents for TT-KS H

Page 1: ...tion and technical manual ElectricCombinationHeatersTT KS GB 2 3 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Edition 07 15 Id_Nr 911 360 950 ...

Page 2: ... 20 Amp double pole switched spur having a contact separation of at least 3mm 1 2 Handling This radiator is very heavy Take adequate precautions when lifting and maneuvering it Always assess the load and seek assistance with heavy or awkward loads that are beyond your capabilities 1 3 Positioning This radiator is very heavy Please refer to Technical Data information contained within this document ...

Page 3: ...onservatories Holiday homes Offices and any other temporary heating situation Our unique patented Magmatic heating tablets provide the heat source for your new radiator Whilst the radiator is classed as a 100 efficient Direct Acting appliance the heating tablets provide partial storage to prolong your heating comfort and to reduce running costs The radiator has a robust body which incorporates a s...

Page 4: ...0 68 x 63 x 7 50 IP 20 TT KS 1500 S 1500 98 x 63 x 7 80 IP 20 TT KS 1800 S 1800 98 x 63 x 7 80 IP 20 TT KS 2000 S 2000 128 x 63 x 7 110 IP 20 TT KS 2400 S 2400 128 x 63 x 7 110 IP 20 TT KS 2800 S 2800 158 x 63 x 7 140 IP 20 TT KS 500 S X4 500 38 x 63 x 7 20 IP 24 TT KS 1000 S X4 1000 68 x 63 x 7 50 IP 24 TT KS 1200 S X4 1200 68 x 63 x 7 50 IP 24 TT KS 1500 S X4 1500 98 x 63 x 7 80 IP 24 TT KS 800 ...

Page 5: ... Manual TT KS GB Note The height of the bracket to the floor is the same height as the bottom of the radiator to the floor Rad Length cm Bracket separation cm 38 55 20 37 68 50 85 67 98 80 128 110 158 140 ...

Page 6: ...ble to locate the studding use Hollow wall anchors and securely fasten the brackets to the plasterboard when this method is used we recommend that radiator feet are used to take the full weight of the radiator For other wall materials the wall panel manufacturer should be consulted for details of suitable wall fixing devices Note Radiators will be set to an approximate height of 185mm from the floo...

Page 7: ...ote It is not allowed to mount the heater in front of a socket outlet 3 2 Electrical connection All TECHNOTHERM TT KS radiators come with a standard UK 3 pin plug that can be directly connected to an electrical socket Alternatively the mains cable can be cut to length and connected to a suitable Fused 20 Amp double pole switched spur adjacent to the radiator Please ensure that the electricity supp...

Page 8: ... frequency RF models All Radio Frequency radiators come complete with a pre wired TRF Receiver which is controlled by either the TPF or TZF control TPF transmitter installation a Follow the instructions outlined on page 27 for single radiator installations according to the instructions included in the TPF transmitter packaging b Locate the TPF programmer on a suitable wall in the same room as the ...

Page 9: ... requirements of EN60 335 the European Standard covering the safety requirements of electric heating appliances and momentary contact with any part of the radiator should not cause injury However in order to be effective radiators of any type do get hot especially around the air outlet grille Therefore if aged or infirm persons or young children are likely to be left unsupervised in the vicinity o...

Page 10: ...l switches and contact your supplier or the LHZ Help Desk on 49 0 3722 63370 Always ensure that the radiator is switched off at the wall and fuse is removed before any repair is carried out IMPORTANT Due to the newness of the materials the radiator will produce a slight smell for the first few days of operation ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN CAGED BIRDS OR PERSONS WITH RESPIRATOR...

Page 11: ...leaning powders or furniture polish Discoloration of wall finishes can sometimes occur immediately above a radiator due to the properties of some paints and decorating materials or the presence of environmental impurities in the air such as soot or incense generated from the burning of candles etc Lucht LHZ Elektroheizung GmbH Co KG Obere Hauptstr 61 D 09232 Hartmannsdorf Fon 49 0 3722 63370 Fax 4...