Summary of Contents for ECO STRIP 0.50

Page 1: ...Uninterruptible Power Supply ECO STRIP 0 50 ECO STRIP 0 70 ECO STRIP 0 90 ECO STRIP 1 1 ECO STRIP 1 3 User s manual...

Page 2: ......

Page 3: ...ristics 10 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Battery Replacement 11 9 4 Operator Safety 12 10 Troubleshooting 13 Conformity to the European Directives 14 Product Disposal 14 Lead...

Page 4: ...ed to the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by remo...

Page 5: ...perator for the UPS correct installation and gives useful advice on the product and battery maintenance For any type of problem please refer to this manual before calling the customer service ECO STRI...

Page 6: ...designed to operate in a protected environment e g offices We therefore recommend installing it in a place with very little or no humidity dust or smoke In all circumstances see the Technical Charact...

Page 7: ...are see figure 1 1 The ON OFF button enables the user to turn ON OFF the UPS 2 The LINE BATTERY led this led blue color is always on during the functioning in Normal Mode it flashes one time every 4...

Page 8: ...s 8 Computer Interface USB connector it is the communication USB port only for ECO STRIP 0 90 1 1 and 1 3 On ECO STRIP up side there are see figure2 9 Grounded UPS Output receptacles Italian 10A Schuk...

Page 9: ...be sure that all the devices connected to the UPS outputs are working correctly 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the UPS emits an acoustic a...

Page 10: ...operate for approximately one more minute During Low Battery condition the UPS emits an acoustic alarm signal every second and simultaneously the LINE BATTERY led flashes If AC Input does not come ba...

Page 11: ...ff 7 Communication Interface The UPS only for ECO STRIP 0 90 1 1 and 1 3 is factory equipped with USB Communication Interface On the UPS rear side there is the connector of the USB Interface The USB s...

Page 12: ...Waveform Modified Sinewave Accepted Overload 130 Certifications CE Standards CEI EN 62040 1 2009 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed fre...

Page 13: ...a month Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient tem...

Page 14: ...t lay tools or metal parts on top of batteries e Disconnect the charging source prior to connecting or disconnecting battery terminals f Determine if battery is inadvertently grounded If inadvertently...

Page 15: ...in powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colour...

Page 16: ...as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same o...

Page 17: ...TECNOWARE s r l www tecnoware com...