background image

Copyright © 2017, All Rights Reserved. 

Ver: R01    D/C: 106-1121

 

AG-300 Plus2   

 

Gateway  

Operation Manual 

Summary of Contents for AG-300 Plus2

Page 1: ...Copyright 2017 All Rights Reserved Ver R01 D C 106 1121 AG 300 Plus2 Gateway Operation Manual ...

Page 2: ...instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measure...

Page 3: ...2 Equipment wiring 5 3 RS485 wiring 7 4 Power bank wiring 8 5 Equipment dimension 8 6 AG 300 Plus2 view 9 Equipment setup 10 1 Network setup 10 2 Account setup 12 3 VB200 setup 14 4 Wireless setup 17 4 1 The wireless AP mode configuration WiFi mode setup 17 4 2 WiFi mode setting 22 5 Hardware setup 26 APP software operation 27 ...

Page 4: ...s for measuring temperature and vibration at equipment power contact E M rotary machinery and motor on the spot In addition it combines measurements made on site with interactive analysis and diagnosis of the system to provide instant helpful and effective target E M equipment health analysis which in turn not only enable easy manufacturing E M equipment management and upkeep in healthy status but...

Page 5: ...Tecom AG 300 Plus2 IoT Gateway Operation Manual In situ and instant vibration diagnosis information Productivity 4 0 ...

Page 6: ...ith RS485 1 2 B Connect AG 300 Plus2 DC Jack to power bank to the power cord C WiFi connect smartphone to built in WiFi router of AG 300 Plus2 D Mount magnetic vibration gauge to target equipment according to its installation guidelines IR temperature sensor VB 200STU VB 200STU Mobile communication gateway AG 300 Plus 2 Power bank Tecom smart portable Target E M Motor Compressor Fan Generator Pump...

Page 7: ... F for computer and the Internet connection as required E Connect AG 300 Plus2 WAN port blue and LAN port of ADSL modem with network cable F Connect AG 300 Plus2 LAN port yellow and PC with network cable for system setup only RS485 1 RS485 2 A B C RS485 AG 300 Plus2 e Gateway VB 200STU Vibration gauge VB 200STU Vibration gauge VB 200STU Vibration gauge VB 200STU Vibration gauge IR Temp Sensor Powe...

Page 8: ...his portable vibration diagnosis instrument comes with 2 built in vibration gauges VB 200STU featuring integrated RS485 cable and USB connector the latter may direct connect to e gateway AG 300 Plus2 as shown inthe figure below A B C RS485 C A AG 300 Plus2 ADSL modem The Internet e Gateway Comput RS485 USB set 1 VB 200STU RS485 USB set 2 VB 200STU RS485 USB set 3 Reserved RS485 USB set 4 Reserved ...

Page 9: ...g to DC jack of AG 300 Plus2 and USB connector to USB port in power bank as shown in figure below 5 Equipment dimension AG 300 Plus2 dimension 130mm length x 90mm width x 36 mm height VB 200STU VB 200STU vibration gauge RS485 USB Magnetic vibration gauge AG 300 Plus2 Target E M equipment motor Power bank power cord Power bank e gateway AG 300 Plus2 DC power plug USB ...

Page 10: ...Tecom AG 300 Plus2 IoT Gateway Operation Manual 6 AG 300 Plus2 view ...

Page 11: ... 300 Plus2 in the same LAN segment better have DHCP enabled on your PC NB Connect PC NB and AG 300 Plus2 LAN port with Ethernet cable Connect power adaptor to AG 300 Plus2 Open a browser on the connection input AG 300 Plus2 setup page address http 192 168 168 10 Input user name admin Input password IP585xAdmin Click OK ...

Page 12: ... data Default gateway input default gateway data Primary DNS server input main DNS server data Secondary DNS serverinput secondary DNS server Click the Apply button at bottom of page once all settings were made successfully Try connecting to popular web sites e g edition cnn com and www yahoo com tw to validate external networking function Set smartphone APP communication port to TCP 53100 53199 i...

Page 13: ...G 300 Plus2 IoT Gateway Operation Manual 2 Account setup Step 1 In main menu on the left click Settings Unit pairing before selecting Add button Step 2 Check the Select column before selecting the Edit button ...

Page 14: ...nual Name input user name Account e g 103 you can have 20 account with number in range of 100 119 Password input password better the same as account ID Click Save button at bottom of page to keep settings you have made Click Start pairing button ...

Page 15: ...bration gauge only factory default of this portable vibration diagnosis instrument may connect two VB 200 series vibration gauge please connect the latter to the 1st and 2nd RS485 port of AG 300 Plus2 the 3rd and 4th RS485 ports are reserved for expansion in the future to connect 3 or more VB 200 series vibration gauge you need to add RS485 device in the management page first Connect only one VB 2...

Page 16: ...ual Name VB 200 or any name you like Line select line 3 4 line 1 2 added by factory default RS485 ID please fill in a value compliant with your RS485 configuration this system support RS485 ID in range of 0 15 Click Save button at bottom of page ...

Page 17: ...ck the Select column click the Edit button and the existing settings display for you to change To delete settings of VB 200 check the Select column click the Delete button to remove the VB 200 vibration gauge To add VB 200 vibration gauge click the Add button to add new VB 200 setup ...

Page 18: ...ns options of WiFi mode Basic Advanced Security and Station list You may set WiFi mode into Wireless AP mode and Wireless client mode The wireless AP mode is an AP with gateway serving as WiFi access point The wireless client mode set the gateway as a client to connect to other WiFi AP 4 1 The wireless AP mode configuration WiFi mode setup ...

Page 19: ...ual 4 1 1 Basic wireless settings This option enables user to set up basic wireless communication parameters including network name and mode with WiFi function default to Enable WiFi Enable page see figure below WiFi Disable page see figure below ...

Page 20: ...nel with page as shown in figure below 4 1 3 Wireless security encryption settings This option is aimed at setting up wireless security and encryption to prevent equipment access and monitoring without certification available security modes are WPASKWPA2PSK and Disable with factory default set to the latter See figure below for page of this option ...

Page 21: ... AG 300 Plus2 IoT Gateway Operation Manual Set up WPA algorithm pass phrase and key renewal interval once set up and saved successfully users are required to input pass phrase set up here to connect to WiFi ...

Page 22: ...Tecom AG 300 Plus2 IoT Gateway Operation Manual The client end is required to log in WiFi router of e gateway AG 300 Plus2 with his her smartphone ...

Page 23: ...ecom AG 300 Plus2 IoT Gateway Operation Manual 4 1 4 Station list Users of this solution may monitor clients connected to AP 4 2 WiFi mode setting Select STA mode and click Apply in the WiFi mode setting ...

Page 24: ...splays information of APs saved in the gateway you may add delete and edit information of desired AP select an AP and click Open the gateway will then auto connect to the AP even after gateway restart connection to pre set AP will be established automatically Click the Add or Edit button and the AP data edit page displays ...

Page 25: ...e In most cases users may change parameters of Name SSID BSSID and Security policy and leave default value of the others intact in the station profile edit page Name name of the profile SSID name of AP BSSID MAC address of AP Security policy encryption mechanism of given AP ...

Page 26: ...Tecom AG 300 Plus2 IoT Gateway Operation Manual 4 2 3 Station link status Link information after gateway connected to AP is shown here 4 2 4 Scan near AP ...

Page 27: ...ted Click Rescan to scan neighboring APs once again Scanning may fail to identify all APs when there are many available nearby rescan couple of times may be needed in case like this Click the Add profile button to save AP data in station profile file 5 Hardware setup AG 300 Plus2 pins definition diagram Vibration gauge RS485 USB Vibration gauge RS485 USB LAN port WAN port Power Reserved ...

Page 28: ...osis APP on your smartphone 2 This vibration diagnosis instrument provides PnP quick online diagnosis log in account 100 119 without other parameter settings as shown in figure below 3 Input Account 100 Password 100 Address 192 168 168 10 Name 100 or custom values defined earlier initial values of account password and name are set to be the same the system comes with 20 accounts 100 119 for equipm...

Page 29: ...P wizard to get complete vibration analysis and diagnosis report 3 Report management Access and manage reports provided by the system distribute them to relevant personnel by email or communication software anywhere anytime 6 If you have checked the Remember Account option you may click the V icon on the right of account direct and fast login as shown in figure below 7 Please check steps below if ...

Page 30: ...erview option to get Host ID in the System Info window TECOM Corp Ltd No 23 R D Rd II Hsinchu Science based Industrial Park Hsinchu Taiwan 300 TEL 886 3 5775141 FAX 886 3 5776855 http www tecom com tw Distributor Ver 02 2017 11 This manual may be modified when necessary because of improvement of the product modification or change in specifications This manual is subject to change without notice ...

Reviews: