DMM-136A DIGTAL MULTIMETER

 

Opera5on Manual

 

CONTENTS 

GENERAL DESCRIPTION …………………………… 
SAFETY PRECAUTIONS……………………………… 
FEATURES ………………………………………… 
OPERATION INSTRUCTION………………………… 
MAINTENANCE ………………………… 
TROUBLE SHOOTING ………………………… 

1.

  General Descrip5on 

This is a 3 5/6 digital mulDmeter with high stability and performance. It uses a LCD with 
20mm high figure, which makes the reading clearer and the operaDon more convenient. 
It  can  test  DCV,  ACV,  DCA,  ACA,  resistance,  capacitance,  frequency,  NCV,    duty  cycle, 
temperature,  diode,  and  conDnuity.  This  meter  also  designed  with  funcDons  including 
unit  symbol  display,  data  hold,  lighDng,  auto  range,  auto  power  off  and  warning 
funcDons.  To  assure  high  accuracy  and  resoluDon,  it  adopts  integrated  circuit  8-bit 
microprocessor and a dual integral A/D conversion as LCD driver, giving high resoluDon 
and high accuracy. It is an ideal tool for labs, factories and radio-technology. 

2.  Safety Instruc5ons 

The instrument is designed in compliance with IEC1010 standard (safety standard issued 
by  InternaDonal  Electro  technical  Commi]ee).  Please  read  the  following  safety 
instrucDons before operaDon. 

2.1 Check the connecDon and insulaDon of test leads to avoid electric shock. 
2.2  To  avoid  electric  shock  and  damage  to  the  meter,  do  not  input  voltage  exceeding 
rated value. 
2.3 When measuring voltage higher than DC 60V or AC 40V, please be careful and avoid 
electric shock. 
2.4 Select correct funcDon and range to avoid wrong operaDon. 
2.5 Move the test leads away from test points when switching to other funcDon. 
2.6 Don’t input voltage in current terminal. 
2.7 Don’t make any modificaDon to the circuit. It may damage the meter or jeopardize 
safety. 
2.8 Safety symbols: 
  “

”  High  voltage,  “ ”  GND,  “ ”  Dual  insulaDon,  “

”  Refer  to  manual,  “ ”  Low 

ba]ery indicaDon. 

3.  Features  

3.1 General CharacterisDcs 
3.1.1 Display: LCD; 

3.1.2 Max display: 6000 (3 5/6 digits, automaDc polarity, and unit symbol display); 
3.1.3 Measurement method: Analog to digital converter (in micro processor ADC+MCU); 
3.1.4 Sampling rate: approx.3 Dmes/sec. 
3.1.5 Over-range display: “OL” displayed. 
3.1.6 Low ba]ery indicator: “ ” 

3.1.7 Working environment: (0

40)

, relaDve humidity: <80%; 

3.1.8 Store condiDon: (-10

50)

, relaDve humidity: <80% 

3.1.9 Ba]ery: 2 pieces 1.5V ba]ery (“AAA” 7# ba]ery); 
3.1.10 Dimension: 140×72×37mm (length x width x height); 
3.1.11 Weight: approx. 195g (including ba]ery); 
3.1.12  Accessories:  test  leads,  TP01  thermocouple,  user  manual,  holster,  gip  box,  and 
2*1.5V ba]eries. 

3.2 Technical Features 
3.2.1  Accuracy:  ±  (a%  ×  reading  +  digits).  To  assure  accuracy,  the  ambient  temperature 
should  be  (23±5) 

,  relaDve  humidity  <75%.  One  year  accuracy  is  guaranteed  since 

producDon date. 

3.2.2 DC Voltage

DCV

 

Input impedance: at 200mv range >40MΩ, at other ranges is 10MΩ. 

Overload protecDon: 600V DC/AC rms. 

3.2.3. AC Voltage

ACV

 

Range

Accuracy

Resolution

600mV

±(0.5%+4)

0.1mV

6V

1mV

60V

10mV

600V

±(1.0%+4)

100mV

Range

Accuracy

Resolution

6V

±(0.8%+6)

1mV

60V

10mV

600V

±(1.0%+6)

100mV

Summary of Contents for DMM-136A

Page 1: ...ctric shock 2 4 Select correct funcDon and range to avoid wrong operaDon 2 5 Move the test leads away from test points when switching to other funcDon 2 6 Don t input voltage in current terminal 2 7 Don t make any modificaDon to the circuit It may damage the meter or jeopardize safety 2 8 Safety symbols High voltage GND Dual insulaDon Refer to manual Low ba ery indicaDon 3 Features 3 1 General Char...

Page 2: ...0 5A 250V fuse and 10A 250V fuse Frequency response 10A range 40 100Hz other ranges 40 400Hz 3 2 6 Resistance Ω Open circuit voltage 500mV Overload protecDon 250V DC AC peak value 3 2 7 Capacitance C Overload protecDon 250V DC AC peak value 3 2 8 Frequency Range Accuracy ResoluDon 600uA 1 0 5 0 1μA 6000uA 1μA 60mA 10μA 600mA 100μA 6A 1mA 10A 2 0 5 10mA Range Accuracy ResoluDon 600uA 1 5 5 0 1μA 60...

Page 3: ...is less than 50Ω buzzer sounds conDnuously Open circuit voltage 2 2V Range Accuracy ResoluDon 40 1000 400 1 0 5 400 1 5 15 1 0F 1832 750 1 0 5 750 1 5 15 Number Feature DescripDon 1 Relative REL mode is active 2 Data Hold is acDve 3 Indicates negaDve readings 4 DC DC voltage or current measurement 5 AC AC voltage or current measurement 6 AUTO Auto range mode 7 Null 8 Diode test mode 9 The conDnuit...

Page 4: ... be displayed Press HOLD again to exit the HOLD mode 2 Light Key Press HOLD key for more than 2 seconds to turn on the backlight The backlight can last for 15 seconds During 15 seconds press light key for 2 seconds again to turn off the backlight Non contact voltage detector area Holster Ba ery door See picture 4 2 DCV measurement 4 2 1 Insert the black test lead into COM terminal and the red one i...

Page 5: ... current is 600mA or 10A subject to which terminal the red test lead is inserted into Current exceeding rated value will damage the fuse and may cause damage to the circuit of meter 4 5 ACA measurement 4 5 1 Insert the black test lead into COM terminal and the red one into VΩmA terminal Max 200mA or into 10A terminal Max 10A 4 5 2 Turn the rotary switch to a proper current range Press SELECT key t...

Page 6: ...1 Even if there is no voltage indicaDon there may be voltage on the circuit Do not rely on NCV detector as the only way to detect voltage 2 Voltage detecDng may be affected by power socket design type of insulaDon and its thickness and other factors 3 Interference sources in the external environment such as flashing light motor would cause wrong signal to acDvate alarm funcDon 4 10 DIODE AND CONTINU...

Page 7: ...with a new one To extend the using life it s be er to use alkaline ba ery Fix the ba ery door Put on the holster 10 Fuse replacement When replacing fuse please use fuse with same type and specificaDon Remove the holster first then screw off the fixing screws of the ba ery door and back cover to remove the cover Take off the old fuse and replace with a new one Install the back cover then fix the screws o...

Reviews: