Page 2: ...ING FIRMWARE USING USB CABLE 22 5 OPERATIONAL BASICS 23 5 1 OPERATIONAL PRINCIPALS 23 5 2 SLEEP MODES 24 5 2 1 Sleep mode 24 5 2 2 Deep Sleep mode 24 5 3 VIRTUAL ODOMETER 25 5 4 FEATURES 25 5 4 1 Scenarios 25 5 4 2 Trip 26 5 4 3 Geofencing 26 5 4 4 iButton list 26 5 5 CONFIGURATION 27 5 6 CONFIGURATOR 27 5 7 RECORD STORAGE 29 5 8 SYSTEM SETTINGS 29 5 9 RECORDS SETTINGS 31 5 10 GSM SETTINGS GPRS PA...

Page 3: ... 61 8 2 4 Stop Detection Source ID 1002 61 8 2 5 Static Navigation ID 1003 62 8 2 6 Ignition source ID 1004 62 8 2 7 Power Voltage High Level ID 1005 62 8 2 8 Power Voltage Low Level ID 1006 62 8 2 9 Saving Sending without time synchronization ID 201 62 8 2 10 GNSS System ID 202 62 8 2 11 GNSS fix Timeout ID 1007 63 8 2 12 NTP Time Synchronization ID 1008 63 8 3 RECORDS PARAMETERS 63 8 3 1 Sorting...

Page 4: ...iod ID 1570 70 8 5 4 2 Min Distance ID 1571 70 8 5 4 3 Min Angle ID 1572 70 8 5 4 4 Min Saved Records ID 1573 71 8 5 4 5 Send Period ID 1574 71 8 5 4 6 GPRS Week Time ID 1575 71 8 5 4 7 Min Speed ID 1576 71 8 5 4 8 Min Speed Source ID 1577 71 8 5 5 Unknown Network GSM operator code Vehicle on STOP parameters 72 8 5 5 1 Min Period ID 1580 72 8 5 5 2 Min Saved Records ID 1583 72 8 5 5 3 Send Period ...

Page 5: ...ID 1104 80 8 6 24 6 Radius ID 1105 80 8 6 25 Button List ID 1610 1659 80 8 7 I O PARAMETERS 80 8 7 1 I O 1 property parameter ID 1300 80 8 7 2 I O 1 priority ID 1301 81 8 7 3 I O 1 High level ID 1302 81 8 7 4 I O 1 Low level ID 1303 81 8 7 5 I O 1 logic operand ID 1304 81 8 7 6 I O 1 averaging length ID 1305 81 8 8 LV CAN PARAMETERS 83 8 8 1 LVCAN mode ID 1600 83 8 8 2 Send data with 0 if ignition...

Page 6: ...6 10 4 CONNECTING GROUND WIRE 104 11 CHANGE LOG 106 ...

Page 7: ...er contains information on how to operate FMA120 safely By following these requirements and recommendations you will avoid dangerous situations You must read these instructions carefully and follow them strictly before operating the device The device uses a 10 V 30 V DC power supply The nominal voltage is 12 V DC The allowed range of voltage is 10 V 30 V DC To avoid mechanical damage it is advised...

Page 8: ...stored in FMA120 memory AVL data contains GPS and I O information AVL packet data packet that is being sent to server during data transmission AVL packet contains from 1 to 50 records 2 BASIC DESCRIPTION FMA120 is a terminal with GPS and GSM connectivity which is able to determine the object s coordinates and transfer them via the GSM network This device is perfectly suitable for applications whic...

Page 9: ...tal inputs 1 analog input 2 open collector digital outputs 1Wire temperature sensor 1Wire iButton LEDs indicating device status Special features Any element event triggers external sensor input speed temperature etc Highly configurable data acquisition and sending Multiple Geo fence areas Sleep mode Deep sleep mode Configurable scenarios available Real time process monitoring Authorized number lis...

Page 10: ...sumption1 GPRS 120 mA r m s Max Nominal average 65 mA r m s Deep Sleep average less than 5 mA2 Battery charge current average 115 mA Operation temperature 25 C 55 C Storage temperature 40 C 70 C Storage relative humidity 5 95 no condensation Internal fuse 3A 125V Modem LED LED Socket 2x5 Tyco Micro MATE N LOK 4 794628 0 or similar USB Mini USB socket Table 1 FMA120 specifications 1 Energy consumpt...

Page 11: ... Power Wh Charging temperature range C Li Polymer rechargeable battery 3 75 3 90 170 0 64 0 66 0 45 CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Battery Disposal instructions Battery should not be disposed of with general household waste Bring damaged or worn out batteries to your local recycling center or dispose the...

Page 12: ...hm Input Voltage Recommended Operating Conditions 0 Supply voltage V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 DIN3 2 6 V Digital Output Open Drain grade Drain Current Digital Output OFF 120 uA Drain Current Digital Output ON Recommended Operating Conditions 3 3 A Static Drain Source Resistance Digital Output ON 300 mOhm Analog Input Input Voltage Recommended Operating Condit...

Page 13: ...mbers and it cannot be 0 This measurement is influenced by hardware components 2 6 Absolute Maximum Ratings VALUE CHARACTERISTIC DESCRIPTION Min Typ Max Unit Supply Voltage Absolute Maximum Ratings 32 32 V Drain Source clamp threshold voltage Absolute Maximum Ratings Idrain 2mA 36 V Digital Input Voltage Absolute Maximum Ratings 32 32 V Analog Input Voltage Absolute Maximum Ratings 32 32 V 3 1 wir...

Page 14: ...14 3 CONNECTION PINOUT ACCESSORIES 3 1 How to insert SIM card into FMA120 device Gently open FMA120 case using screwdrivers Remove FMA120 case Insert SIM card as shown ...

Page 15: ...3 or later Windows Vista Windows 7 MS NET Framework V3 5 or later http www microsoft com Drivers Please download Virtual COM Port drivers from Teltonika website http avl1 teltonika lt downloads FM11YX vcpdriver_v1 3 1_setup zip Installing drivers Extract and run VCPDriver_V1 3 1_Setup exe This driver is used to detect FMA120 device connected to the computer Click Next in driver installation window...

Page 16: ...owing window click Next button again Figure 3 Driver installation window Setup will continue installing drivers and will display a window about successful process at the end Click Finish to complete setup Figure 4 Driver installation window You have now installed drivers for FMA120 device successfully ...

Page 17: ... 3 4 Status LED Behaviour Meaning Blinking every second Normal mode Blinking every 2 seconds Deep sleep mode Blinking fast for a short time Modem activity Blinking fast constantly Boot mode Off Device is not working Or Device firmware being flashed 3 5 Socket 2 5 DIN 1 IGNITION 5 10 Ucc_DALLAS DIN 2 4 9 DIN 3 OUT 1 3 8 DATA_DALLAS OUT 2 2 7 AIN 1 VCC 10 30 V DC 1 6 GND VCC 10 30 V DC Figure 5 2x5 ...

Page 18: ...GNITION INPUT 6 GND VCC 10 30 V DC Ground pin 10 30 V DC 7 AIN 1 Analog input channel 1 Input range 0 30V 0 10V DC 8 DATA_DALLAS Data channel for Dallas 1 Wire devices 9 DIN 3 Digital input channel 3 10 Ucc_DALLAS 3 8 V output for Dallas 1 Wire devices max 20mA Table 2 Socket 2x5 pinout description 3 6 USB Mini USB connector Figure 6 Mini USB type B connector FMA120 connected to PC creates an STM ...

Page 19: ...ermometer DS1820 DS18S20 and DS18B20 and I Button type DS1990A Figures 8 and 9 show FMA120 and 1 wire device connection schemes Left row of pins 1 3 4 1 2 2 J1 J2 J3 U1 Right row of pins 1W PWR FMA120 pin10 1 1W Data FMA120 pin8 2 1 Vpp 5 Volts DC power source for external digital sensor GND FMA120 pin6 3 2 Output from external digital sensor Digital Input 4 Figure 8 Digital thermometer DS1820 and...

Page 20: ... FMA120 and fuel tank sensor After the connection to the tank fuel level sensor calibration is needed Calibration is needed because most fuel tank sensors are not linear Calibration is performed by measuring voltage dependence on volume of fuel in tank Alarm buttons door sensors etc Alarm buttons door sensors ignition etc return two states high or low voltage Digital inputs are used to read this i...

Page 21: ...tion Immobilizer relay When connected as shown below FMA120 disables engine starter when output is ON More details about relays can be found below Figure 13 Immobilizer relay connection Relays An ordinary automotive relay is used to invert input signal or to immobilize engine starter Note that they are available as 12 V or 24 V Figure 14 Automotive relay pinout ...

Page 22: ...nect and when IMEI and Firmware version fields are filled start the update Device needs some time to send IMEI and Firmware version so do not be afraid if IMEI will not show up immediately disconnect and after 1 2 minutes try to connect again When starting update device will open link with updater With link open device downloads firmware and starts installing Wait thru all these screens as in Figu...

Page 23: ...er coordinate in these records remains the same last known coordinate Method s details are described in section5 13 All data is stored in flash memory and later can be sent via GPRS or SMS GPRS mode is the most preferred data sending mode SMS mode is mostly used in areas without GPRS coverage or GPRS usage is too expensive GPRS and SMS settings are described in later sections FMA120 communicates w...

Page 24: ...eep mode While in deep sleep mode FMA120 sets GPS receiver to sleep mode and turns off GSM GPRS module it is possible to wake up device via SMS Despite records with last known coordinate are being saved and send to AVL server GSM GPRS module is turned on to send data and after that it is turned off again power usage is decreased to save vehicle s battery Note that power saving depends on two confi...

Page 25: ...d to manage digital output 1 and digital output 2 A single digital output can be controlled by a few scenarios However it is not recommended to configure Immobilizer and other scenarios on the same digital output Green Driving Scenario Helps to inspect driver and prevent about harsh driving Scenario continuously monitors accelerating force braking force and cornering angles and warns driver if nee...

Page 26: ...ring of performed trips from engine start at present location to engine stop at arrived location log their start and stop points view driven total distance4 Event will be generated included into send records only when trip starts and finishes Note Scenarios and Trip features are activated DOUTs are activated only if configured Ignition Source 1 ignition is on 5 4 3 Geofencing Geofencing is another...

Page 27: ...official Microsoft web page Module configuration is performed over USB cable Configuration process starts from starting FMA120 Configurator program and then connecting to FMA120 device via Connect button located on the top left corner of configurator If connected successfully IMEI Version fields which were empty now are filled with certain numbers depending on Modem IMEI and firmware version of yo...

Page 28: ...meters from FMA120 Flash memory Save saves configuration parameters to FMA120 Flash memory Load Defaults loads default FMA120 settings that later can be modified This procedure must be performed before entering new parameters Save to File allows user to save currently entered settings to XML file for later usage Load from File allows user to load configuration saved in XML extension file Reset dev...

Page 29: ...g on GPRS server load You can access all uploaded data from TAVL4 application More details on how to use TAVL application please refer to TAVL4 application user manual documentation 5 8 System settings System settings have 7 configurable parameters Deep sleep settings where user can turn deep sleep on or off Analog Input Settings where user can choose analog input range 10 V or 30 V depending on n...

Page 30: ...and vehicle speed is higher than 5 km h While GPS fix is unavailable Object Motion Detection Settings are working like in Msensor mode Static Navigation Mode is a filter which filters out track jumps when the object is stationary If Static navigation filter is disabled it will apply no changes on GPS data If Static navigation filter is enabled it will filter changes in GPS position if no movement ...

Page 31: ...ain parameters for FMA120 GSM operator APN and GPRS username and password optional depending on operator destination server IP and port and allows to set protocol used for data transfers TCP or UDP Some operators use specific authentication for GPRS session CHAP or PAP If any of these is used APN should be entered as chap APN or pap APN I e if operator is using APN internet with CHAP authenticatio...

Page 32: ...et in SMS Week Time tab 24 Coordinates SMS decoding is described in device protocols documentation Please contact Teltonika sale manager to find out more about protocols documentation purchase Figure 22 SMS configuration Note A mobile phone will not understand and SMS with binary code so sending it to a mobile phone is useless When sending a binary SMS to a phone number which is a server phone num...

Page 33: ...make sure it is configured to allow data sending GPRS context is enabled Operator Blacklist Operator BlackList Functionality algorithm Device tries to connect to an operator with the strongest signal It will prioritize operators which are specified in the operator list If no operators from the operator list are available the device will try to connect to an operator from the blacklist If the devic...

Page 34: ...evice it is also highly configurable By configuration user defines how records will be saved and sent There are three different modes Home Roaming and Unknown All these modes with configured data acquisition and send frequencies depend on current GSM Operator defined in Operator list see section 0 and are switched when GSM operator changes e g vehicle passes through country boarder ...

Page 35: ...is moving or stands still Vehicle moving or stop state is defined by Stop Detection Source parameter There are 3 ways for FMA120 to switch between Vehicle on Stop and Vehicle Moving modes see section 5 7 FMA120 allows having 6 different modes Operational logic is shown in Figure 24 If there are no operator codes entered into operator list FMA120 will work in Unknown network mode ONLY Figure 24 Dat...

Page 36: ...36 Figure 25 Data Acquisition Mode configuration ...

Page 37: ...nds on GSM network provider GPRS Context Week Time defines session re establish schedule if session was closed by network New GPRS context is opened if time is 10 minutes till time checked in table Therefore if all boxes are checked FMA120 is able to open new connection anytime At scheduled time match FMA120 checks for GPRS session activity If GPRS session is alive FMA120 sends data to server acco...

Page 38: ...e and current position is greater than defined parameter value Entering zero disables data acquisition depending on distance Min distance Figure 28 Distance based data acquiring example Angle based data acquiring Min angle records are being acquired when angle difference between last recorded coordinate and current position is greater than defined value Entering zero disables data acquisition depe...

Page 39: ...econfigured allowed value 7sec if detected value is over 50 from preconfigured allowed value After period of time DOUT1 DOUT2 is turned OFF Over Speeding If Dout Control is disabled scenario only generate events without digital output activation If Dout Control is enabled DOUT1 DOUT2 optional is ON while vehicle speed exceeds the parameter value DOUT1 DOUT2 remains active until current speed decre...

Page 40: ...st 5 14 2 Trip settings If Trip is enabled following parameters are configurable Start Speed GPS speed has to be greater than the specified Start Speed in order to detect Trip Start Ignition Off Timeout timeout to wait if ignition configured Ignition Source was off to detect Trip stop Continuous distance counting Not or Continuous can be chosen For this feature I O Trip distance must be enabled If...

Page 41: ...his parameter can not be configured via TCP config If this value is not set FMA110 starts counting from 0 Continuous odometer works irrespective of the Trip functionality Figure 36 Continuous odometer setting in configurator Remember iButton functionality If Remember iButton ID while trip detected and Trip parameters are enabled ignition is on and iButton is attached then FMA110 remembers iButton ...

Page 42: ...re 31 for details track 1 is considered to have entered the area while track 2 is not Track Nr 1 Track Nr 2 Figure 34 Geofence border Shape can be rectangle or circle Priority priority of Geofence event low high or panic These levels define priority of event information sending to server See I O element description for more details about priorities Generate event On entrance On exit On Both choose...

Page 43: ...ition Source becomes high it will disable AutoGeofenze Zone iButton if iButton is attached it will disable AutoGeofence Zone Edit iButton List if list is not empty attached iButton is tested against an iButton list if match is found AutoGeofence zone is disabled Priority Priority of generated event which will be applied to saved record Enter Event Event generation on Geofence entrance Exit Event E...

Page 44: ...n Driving OverSpeeding Authorized Driving Immobilizer Trip start stop Geofence AutoGeofence I O event When any of the above events is triggered FMA120 sends a configured SMS message to a defined phone number If SMS events is activated but there are no numbers defined in SMS events PreDefined Numbers list figure 34 then the device will not send any messages SMS events can be activated in FMA1YX con...

Page 45: ... an SMS when Digital Input 1 reaches High level with priority High and configured to generate event on both range enter and exit figure 35 then the sent SMS is 2012 6 7 12 00 00 Digital Input 1 Figure 38 Configured Digital Input 1 SMS event The SMS Text field can be altered and any text can be entered Maximum message length is 90 symbols numbers letters and symbols in ASCII except for comma ...

Page 46: ...4 1 SMS events configuration Scenarios To configure SMS events for scenarios open Scenarios window and Enable desired scenario Then go to GSM SMS SMS events window and activate SMS event for Enabled scenario Figure 36 shows how to enable Green Driving and Authorized Driving SMS Events Note that Green Driving can t work together with Over Speeding and Authorized Driving can t work together with Imm...

Page 47: ...longer then the time written in Ignition Off Timeout ex 60 seconds Figure 40 Trip Start Stop SMS event configuration Figure 41 Trip Start Stop SMS event configuration Geofence Geofence SMS event is triggered and message sent when the device exits and or enters a configured Geofence zone The Geofence zone must be configured to generate an event On Exit On Enter or On Both figure 39 If No Event is s...

Page 48: ...ence SMS event configuration AutoGeofence SMS events for AutoGeofence are configured the same as in Geofence AutoGeofence is next to Geofence configuration figure 40 for SMS events configuration go to GSM SMS SMS Events ...

Page 49: ... when a configured I O property enters and or exits its configured High Low boundaries or Hysteresis event generation is chosen Monitoring does not generate event so SMS event could not be configured Every IO element SMS event can be configured to send individual message to different numbers ...

Page 50: ...30 V 5 GSM level 1 GSM signal level value in scale 1 5 6 Speed 2 Value in km h 0 xxx km h 7 External Power Voltage 2 Voltage mV 0 30 V 8 GPS Power 2 States 0 GPS module is turned off 2 working but no fix 3 working with GPS fix 4 GPS module is in sleep state 5 antenna is short circuit 9 Dallas Temperature 4 10 Degrees C 55 115 if 3000 Dallas error 10 iButton ID 8 iButton ID number 11 Data Mode 1 0 ...

Page 51: ... zone 27 Geofence zone 03 1 Event 0 target left zone 1 target entered zone 28 Geofence zone 04 1 Event 0 target left zone 1 target entered zone 29 Geofence zone 05 1 Event 0 target left zone 1 target entered zone 30 Auto Geofence 1 Event 0 target left zone 1 target entered zone 31 Trip 1 1 trip start 0 trip stop 32 Immobilizer 1 1 iButton connected 33 Authorized driving 1 1 authorized iButton conn...

Page 52: ...d with high priority flag and sends event packet immediately to the server by GPRS Panic priority triggers same actions as high priority but if GPRS fails it sends AVL packet using SMS mode if SMS is enabled in SMS settings High and Low levels define I O value range If I O value enters or exits this range FMA120 generates event Generate event parameter defines when to generate event when value ent...

Page 53: ...el maximum threshold Low level minimum threshold Generate event on interval enter on interval exit on both enter and exit Average constant 1 232 4 Bytes Figure 47 Digital Input event generation example 5 15 3 Hysteresis Figure 48 Hysteresis parameter configuration I O elements can generate events according to hysteresis algorithm If I O event operand Hysteresis is selected events will be generated...

Page 54: ...es passed since start of week Yes getops List of currently available GSM operator Yes getcfgtime Date and Time of last successful configuration Yes ggps Google Map Link information Yes getgps Current GPS data and time Yes cpureset Reset CPU No resetprof Reset all FLASH1 profile configuration to default profile No getver Device Modem Code version information Yes getinfo Device runtime system inform...

Page 55: ...uest by SMS Yes lvcansetprog Set LVCAN program number Yes lvcangetinfo Get LV CAN info by SMS Yes getcontsens Get IDs of connected temperature sensors Yes 6 1 1 getstatus Response details Description Data Link Indicate module connection to server at the moment 0 Not connected 1 connected GPRS Indicate if GPRS is available at the moment Phone Voice Call status 0 ready 1 unavailable 2 unknown 3 ring...

Page 56: ... TELE2 24603 6 1 4 getcfgtime Response details Description Date Time Returns last performed configuration date and time Example Last Configuration was performed on 2010 4 15 5 45 19 6 1 5 getgps Response details Description GPS Indicates valid 1 or invalid 0 GPS data Sat Count of currently available satellites Lat Latitude Last good Latitude Long Longitude Last good Longitude Alt Altitude Speed Gr...

Page 57: ... Number of Sent Records BR Number of broken records CF Profile CRC Fail counter FG Failed GPRS counter FL Failed link counter UT UPD Timeout counter SMS Sent SMS Counter NOGPS No GPS Timer GPS GPS receiver state 0 OFF 1 restarting 2 ON but no fix 3 ON and operational 4 sleep mode SAT Average satellites RS Reset Source Identification 1 Low Power 2 W Watchdog 3 I Watchdog 4 Software reset 5 Power On...

Page 58: ...4 digits Detailed list of parameters and IDs can be found in chapter number 8 Parameter List Example getparam 1115 command will request server IP address 6 1 14 setparam Sets new value for parameter ID consists of 3 or 4 digits Detailed list of parameters and IDs can be found in chapter number 8 Parameter List Example setparam 1115 127 0 0 1 will change configured IP address 6 1 15 getparam 1271 X...

Page 59: ...ords found on FLASH Minimum Records to Send Number of minimum saved records to send GPRS Enabled State of the GPRS connection 0 disabled 1 enabled Time Sync Indicates time synchronization on the device 0 not synchronized 1 synchronized Example FLUSH SMS Accepted 11 records found on FLASH Minimum Records to Send 1 GPRS Enabled 1 Time Sync 1 6 1 19 sn Enables or disables Static navigation 1 enable 0...

Page 60: ...m http avl1 teltonika lt Downloads Software Terminal zip After launching terminal choose baud rate 115200 and hardware control none Select COM port which is assigned to Virtual COM Port Click on Start Log button and save a new file Then click Connect to start receiving messages from FMA120 Also you can log NMEA data directly To get NMEA data simply enter the following command into the command fiel...

Page 61: ...e Recommended value Goes with depends on parameters Value type 0 2 U8 8 2 2 Sleep timeout ID 200 Sleep timeout is time after which FMA120 goes to sleep or deep sleep if other requirements are met It is measured in minutes Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 3000 U8 8 2 3 Analog Input value range ID 1001 Analog input measuring resolution and ra...

Page 62: ... Power Voltage High level for ignition detection must be set Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 30000 Ignition source ID 1004 Power Voltage Low Level ID 1006 U16 8 2 8 Power Voltage Low Level ID 1006 When ignition source is selected as Power Voltage High level for ignition detection must be set Minimum value Maximum value Recommended value Go...

Page 63: ...e 0 1 1 U8 8 3 Records parameters 8 3 1 Sorting ID 1010 Record sorting parameter is responsible for record sorting order Value of 0 arranging data starting from newest while value of 1 arranging data starting from oldest Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 8 3 2 Active Data Link Timeout ID 1011 Defines for how many seconds device will kee...

Page 64: ... does not allow GPRS usage If GPRS is not allowed value is 0 if GPRS is allowed value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 APN Name ID 1242 APN username ID 1243 8 4 4 APN Password ID 1244 S8 8 4 2 APN Name ID 1242 Parameter defines GPRS Access Point Name Minimum value Maximum value Recommended value Goes with depends on parameters Value ...

Page 65: ...ocol value is 0 for UDP protocol value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 GPRS content activation ID 1240 U8 8 4 8 Always online ID 1248 Parameter allows keeping the link with a server open all the time If Always online mode is not allowed value is 0 if it is allowed value is 1 Minimum value Maximum value Recommended value Goes with de...

Page 66: ...1 digit 16 digits S8 17 If SMS data sending is enabled ID 1130 first value in a list is server GSM number The SMS with 24 coordinates is sent to this number 8 4 14 SMS Event PreDefined Numbers ID 150 159 In this field are written GSM numbers to which will be sent Event SMS text message Number must be entered without or 00 Example 37060012346 Minimum value Maximum value Recommended value Goes with ...

Page 67: ...ter defines minimum number of records in one data packet that can be sent to server It has higher priority than Data Send Period ID 1544 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 GPRS Week Time ID 1545 U8 8 5 1 3 Send Period ID 1544 This parameter indicates frequency time interval in seconds of sending data to server Minimum value Maximum valu...

Page 68: ...meter indicates time interval in seconds in order to acquire new record If value is 0 it means no records by min period will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Distance ID 1551 Min Angle ID 1552 Min Speed ID 1556 GPRS Week Time ID 1555 U32 8 5 2 2 Min Distance ID 1551 This parameter indicates distance in meters in order t...

Page 69: ...tes speed difference in order to acquire new record If speed difference between last recorded coordinate and current position is greater than defined value new record is stored If value is 0 it means no records by min distance will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 255 10 Min Period ID 1550 Min Distance ID 1551 Min Angle ID 1552 Min...

Page 70: ...8 5 4 1 Min Period ID 1570 This parameter indicates time interval in seconds in order to acquire new record If value is 0 it means no records by min period will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Distance ID 1571 Min Angle ID 1572 Min Speed ID 1576 GPRS Week Time 1575 U32 8 5 4 2 Min Distance ID 1571 This parameter indica...

Page 71: ...rval in seconds of sending data to server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records ID 1573 GPRS Week Time 1575 U32 8 5 4 6 GPRS Week Time ID 1575 Read chapter 0 8 5 4 7 Min Speed ID 1576 This parameter indicates speed difference in order to acquire new record If speed difference between last recorded coordinate and current...

Page 72: ...es with depends on parameters Value type 0 2592000 Min Saved Records ID 1583 GPRS Week Time ID 1585 U32 8 5 5 4 GPRS Week Time ID 1585 Read chapter 0 8 5 6 Unknown Network GSM operator code Vehicle MOVING parameters 8 5 6 1 Min Period ID 1590 This parameter indicates time interval in seconds in order to acquire new record If value is 0 it means no records by min period will be saved Minimum value ...

Page 73: ... parameters Value type 1 255 1 Min Period ID 1590 Min Distance ID 1591 Min Angle ID 1592 Min Speed ID 1596 GPRS Week Time ID 1595 U8 8 5 6 5 Send Period ID 1594 This parameter indicates frequency time interval in seconds of sending data to server In order to send data to server GPRS parameters must be enabled Minimum value Maximum value Recommended value Goes with depends on parameters Value type ...

Page 74: ... on parameters Value type 0 2 Green driving scenario ID 1890 U8 8 6 3 Max Acceleration Force ID 1892 It is max allowed acceleration force which can be reached while accelerating without triggering harsh acceleration event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 25 0 85 0 25 Green driving scenario ID 1890 Float 8 6 4 Max Braking Force ID 1893 It is...

Page 75: ...n parameters Value type 0 2 Overspeeding scenario ID 1895 U8 8 6 8 Max allowed speed ID 1897 This parameters defines max allowed speed on Overspeeding scenario Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 260 Overspeeding scenario ID 1895 U8 8 6 9 Jamming scenario ID 1898 This parameter enables disables Jamming scenario 0 disable 1 enable Minimum value...

Page 76: ...scenario ID 1903 This parameter lets enable disable Immobilizer scenario 0 disable 1 enable Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 8 6 15 Immobilizer digital output control ID 1904 This parameter defines digital output control on Immobilizer scenario 0 disable 1 DOUT1 2 DOUT2 Minimum value Maximum value Recommended value Goes with depends on...

Page 77: ...s I O Trip distance value Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 Trip ID 1280 I O 11 Trip distance ID 1410 1415 U8 8 6 21 Remember iButton ID ID 1284 This parameter enables disables Remember iButton ID functionality 0 disable 1 enable Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 Trip ID 1280 iButt...

Page 78: ... 6 23 5 Geofence Zone 1 Longitude X1 ID 1033 Parameter has two meanings dependent on zone shape If shape is a rectangle then ID 10333 is left down corner X coordinate If shape is a circle then ID 1033 is center of that circle X coordinate Sample value 25 30528 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 180 180 All Geofencing parameters Float 8 6 23 6 G...

Page 79: ...shown in GeoFence Zone 1 GeoFence Zone Number Geofence Zone s parameters 1 1030 1036 2 1040 1046 3 1050 1056 4 1060 1066 5 1070 1076 8 6 24 AutoGeofencing 8 6 24 1 Enable Disable ID 1101 Enable value 1 disable value 0 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 1 U8 8 6 24 2 Activation Timeout ID 1102 Parameter represents AutoGeofencing activation t...

Page 80: ... activating AutoGeofence feature Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1000000 100 Enable Disable ID 1101 Deactivate by ID 1100 U32 8 6 25 Button List ID 1610 1659 Read 5 4 4 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 FFFFFFFF FFFFFFFF Immobilizer scenario ID 1903 iButtons list checking ID 1905 U64...

Page 81: ...ID 1305 S32 8 7 4 I O 1 Low level ID 1303 Parameter defines low value of triggered I O property This parameter is used to set thresholds for I O properties to generate events Minimum value Maximum value Recommended value Goes with depends on parameters Value type 2147483647 2147483647 0 I O 1 property parameter ID 1300 I O 1 priority ID 1301 I O 1 High level ID 1302 I O logic operand ID 1304 I O 1...

Page 82: ...Input 1 1330 1335 Digital Output 1 1340 1345 Digital Output 2 1350 1355 GNSS PDOP 1360 1365 GNSS HDOP 1370 1375 External Voltage 1380 1385 GNSS Power 1390 1395 Movement Sensor 1400 1405 Trip distance 1410 1415 GSM Operator 1420 1425 Speed Km h 1430 1435 iButton ID 1440 1445 Mode 1450 1455 GSM Signal 1460 1465 Deep Sleep 1470 1475 Cell ID 1480 1485 Area Code 1490 1495 Dallas Temperature 1 1500 1505...

Page 83: ... with depends on parameters Value type 0 2 0 U8 8 8 2 Send data with 0 if ignition is off ID 1601 This parameter enables disables data sending with 0 value if ignition is off 0 disable 1 enable Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 1 U8 8 9 SMS event configuration 8 9 1 I O 1 element SMS event configuration ID 100 Command sets SMS warning on I...

Page 84: ...16 Deep Sleep 117 GSM Cell ID CID 118 GSM Location Area Code LAC 119 Dallas Temperature 1 120 Digital input 4 121 Analog input 2 122 Battery voltage 123 Battery current 124 Ignition 125 Total distance 126 Reserved for future use 127 Reserved for future use 128 LVCAN Speed 129 LVCAN Accelerator pedal position 130 LVCAN Total fuel used 131 LVCAN Fuel level liters 132 LVCAN Engine RPM 133 LVCAN Vehic...

Page 85: ...tance 111 GSM operator code 112 Speed 113 iButton ID 114 Data mode 115 GSM signal 116 Deep Sleep 117 GSM Cell ID CID 118 GSM Location Area Code LAC 119 Dallas Temperature 1 120 Digital input 4 121 Analog input 2 122 Battery voltage 123 Battery current 124 Ignition 125 Total distance 126 Reserved for future use 127 Reserved for future use 128 LVCAN Vehicle Speed 129 LVCAN Accelerator pedal position...

Page 86: ...ad 221 LVC Axle 3 Load 222 LVC Axle 4 Load 223 LVC Axle 5 Load 224 LVC Control State Flags 225 LVC Agricultural Machinery Flags 226 LVC Harvesting Time 227 LVC Area of Harvest 228 LVC Mowing Efficiency 229 LVC Grain Mown Volume 230 LVC Grain Moisture 231 LVC Harvesting Drum RPM 232 LVC Gap Under Harvesting Drum 233 LVC Security State Flags 234 LVC Tacho Total Vehicle Distance 235 LVC Trip Distance...

Page 87: ...erature 266 LVC Battery Level 267 LVC Door Status 268 LVC Reserved 269 Dallas Temperature 2 270 Dallas Temperature 3 271 Dallas Temperature 4 272 Dallas Temperature 1 ID 273 Dallas Temperature 2 ID 274 Dallas Temperature 3 ID 275 Dallas Temperature 4 ID 276 9 FMA120 with LV CAN200 and ALL CAN300 Can Adapters 9 1 Purpose of Can Adapters LV CAN200 and ALL CAN300 LV CAN200 is used to listening data f...

Page 88: ...heme Please contact Your Teltonika sales manager to get latest supported vehicle list and mounting scheme for your vehicle please provide CAR manufacturer model and year information 9 2 1 LV CAN200 and ALL CAN300 program number configuration via SMS command LV CAN200 and ALL CAN300 program number can be set remotely using SMS command lvcansetprog X X is new program number value 9 2 2 Selecting LV ...

Page 89: ...ter signaling led 9 3 SIMPLE CAN contactless CAN BUS reader SIMPLE CAN is contactless adapter used to read vehicle CAN data with LV CAN200 ALL CAN300 If LV CAN200 or ALL CAN300 connection requires two CAN lines to get all data then you need two SIMPLE CAN readers TECHNICAL DETAILS Power supply voltage 9 63 V Power supply current Mode 12V 24V Active 8 3 mA 4 3 mA Standby 1 6 mA 0 91 mA CAN BUS spee...

Page 90: ...on process takes up to 10 seconds depending on the vehicle s model Correct calibration process is confirmed by LED s every 2 seconds blink when the CAN BUS is active When the CAN BUS enters sleep mode SIMPLE CAN device does it also and takes 1 6mA 12V In the sleep mode LED does not shine If after calibration process LED shines continuously it means that device is not calibrated yet CAN BUS transmi...

Page 91: ...ect adapter from FMA120 and connect PC USB cable to FMA120 Device Figure 55 It is very important not to disconnect FMA120 from power source during this operation because if FMA120 is reconnected all received CAN bus data will be lost FMA120 remembers received data from LV CAN200 or ALL CAN300 and at the end of the procedure when SCAN button is pressed user will see all CAN data which is sent by ad...

Page 92: ...ty is used to store additional AVL packet when state of CAN element is changing For example Speed changes low fuel level engine temperate etc Send data to server field allows enabling CAN element so it is added to the AVL data packet and sent to the server By default all CAN elements are disabled and FMA120 records only GPS data It is possible to set CAN message priority On Low Priority On High Pr...

Page 93: ... configuration Figure 57 Configurator example Available CAN Bus IO parameters and configuration can be found in Configurators CAN tab Figure 59 and in next chapter Parameters ID Send data with 0 if ignition is off Depending on LVCAN ALLCAN I O parameters and ignition status FMA110 can send locked last known LVCAN ALLCAN I O parameters values reset values set to 0 and active real time parameters va...

Page 94: ...vesting Time lock Area of Harvest reset Mowing Efficiency active Grain Mown Volume active Grain Moisture active Harvesting Drum RPM reset Gap Under Harvesting Drum active Security State Flags active Tachograph Total Vehicle Distance lock Trip Distance reset Tachograph Vehicle Speed reset Tachograph Driver Card Presence active Driver1 States active Driver2 States active Driver1 Continuous Driving T...

Page 95: ...Controller 2 1 Accelerator Pedal Position 1 82 0 100 65257 Fuel Consumption 2 Total Fuel Used 4 83 0 99999999 liters 65276 Dash Display 3 Fuel Level liters 2 84 0 255 liters 61444 Electronic Engine Controller 1 4 Engine RPM 2 85 0 8200 rpm 65217 High Resolution Vehicle Distance 5 Vehicle Distance 4 87 0 2145000000 meters 65276 Dash Display 6 Fuel Level 1 89 0 100 Program number 7 LV CAN200 Program...

Page 96: ... 1 Axle 3 Load 49 2 120 kg 1 Axle 4 Load 50 2 121 kg 1 Axle 5 Load 51 2 122 kg 1 Control State Flags 52 4 123 see table 9 2 1 Agricultural Machinery Flags 53 8 124 see table 9 2 1 Harvesting Time 54 4 125 min 1 Area of Harvest 55 4 126 m2 1 Mowing Efficiency 56 4 127 m2 h 1 Grain Mown Volume 57 4 128 kg 1 Grain Moisture 58 2 129 proc 1 Harvesting Drum RPM 59 2 130 Gap Under Harvesting Drum 60 1 13...

Page 97: ...8 149 ASCII Driver2 ID Low 79 8 150 ASCII Battery Temperature 80 2 151 o C x 10 0 1 signed Battery Level percent 81 1 152 proc 1 NOTE Total Fuel Used is sent to server multiplied by 10 Example if value was 150 5 liters 1505 will be sent to server Table 9 2 1 ALLCAN300 IO element values Idx Description Size Bytes AVL ID Value bitmasks 52 Control state flags 4 123 Byte0 LSB 0x01 STOP 0x02 Oil pressu...

Page 98: ...s hydraulic system is plugged 0x40 Alarm oil level in oil tank 0x80 Pressure filter of brakes hydraulic system is plugged Byte2 0x01 Oil filter of engine is plugged 0x02 Fuel filter is plugged 0x04 Air filter is plugged 0x08 Alarm oil temperature in hydraulic system of chasis 0x10 Alarm oil temperature in hydraulic system of drive cylinders 0x20 Alarm oil pressure in engine 0x40 Alarm coolant leve...

Page 99: ...Left joystick moved front 0x08 Left joystick moved back 0x10 Front Power Take Off turned on 61 Security state flags 8 132 Byte0 LSB 0x20 bit appears when any operate button in car was put 0x40 bit appears when immobilizer is in service mode 0x80 immobiliser bit appears during introduction of a programmed sequence of keys in the car Byte1 0x01 the key is in ignition lock 0x02 ignition on 0x04 dynam...

Page 100: ...ontrol High nibble mask 0xF0 bit 0x80 CAN module goes to sleep mode 65 Tachograph driver card presence 1 136 0x00 No driver card 0x01 Driver1 card presence 0x02 Driver2 card presence 0x03 Driver1 and driver2 cards present 66 Driver 1 states 1 137 0xX0 break rest 0xX1 availability 0xX2 work 0xX3 driving 0x0X no time related warning detected 0x1X limit 1 15 min before 4 1 2 h 0x2X limit 2 4 1 2 h re...

Page 101: ...2053 Fuel level proc 2060 2064 Program number 2070 2073 Module ID 2080 2083 Engine Work Time 2090 2093 Engine Work Time counted 2100 2103 Total Mileage counted 2110 2113 Fuel Consumed counted 2120 2123 Fuel Rate 2130 2134 AdBlue Level percent 2140 2144 AdBlue Level liters 2150 2154 Engine Load 2160 2164 Engine Temperature 2170 2174 Axle 1 Load 2180 2184 Axle 2 Load 2190 2194 Axle 3 Load 2200 2204 ...

Page 102: ...ty 0 IO element disabled 1 Low priority 2 High priority 3 Panic priority 2xx1 Generation type 0 Event on exit 1 Event on entrance 2 Event on both 3 Monitoring 4 Hysteresis 5 On change 2xx2 Low level See table 9 5 Allowed Values 2xx3 High Level 2xx4 Averaging Constant From 0 to 232 Table 9 5 LV CAN200 and ALL CAN300 IO parameters allowed values LV CAN200 IO Element Minimum value Maximum value Speed...

Page 103: ...isolation was removed while connecting wires it should be applied again If the wires are placed in the exterior or in places where they can be damaged or exposed to heat humidity dirt etc additional isolation should be applied Wires cannot be connected to the board computers or control units 10 2 Connecting Power Source Be sure that after the car computer falls asleep power is still available on c...

Page 104: ...e fuses of vehicle s computer are wire GND must be connected in a special point designed to connect GND vehicle computer Connecting the GND at an arbitrary point to the mass of the car is unacceptable as static and dynamic potentials on the line GND will be unpredictable which can lead to unstable FMA120 and even its failure Module Installation FMA120 must be placed sticker on TOP please refer pic...

Page 105: ...105 Figure 51 Correct placement of FMA120 ...

Page 106: ...IDs updated Continuous odometer description added Remember iButton functionality description added New I O element 16 Total distance Virtual odometer added setdigoutX Z Y description added GNSS fix Timeout parameter ID added Parameter Odometer value name was changed to Trip distance Added 4 TTJ ID I O elements getcontsens command added LVCAN description updated Send data with 0 if ignition is off ...