background image

 
 

 

To see our TempIR range of products and for customer 

service visit 

www.temp-ir.com 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TempIR 

 

 

 

 

Dual-Mode Infrared Thermometer 

Instruction manual 

                                             

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.temp-ir.com 

 

 

0482 

 

Summary of Contents for Dual-Mode Infrared Thermometer

Page 1: ...To see our TempIR range of products and for customer service visit www temp ir com TempIR Dual Mode Infrared Thermometer Instruction manual www temp ir com 0482 ...

Page 2: ... 15 95 RH 16 Type of measuring Applicable for forehead temperature and ear temperature 17 battery Changeable for two 1 5V triple AAA batteries 18 Battery life More than 3000 times 19 Accuracy for clinical test The maximum allowable error for clinical test is specified in the formula below 0 3 0 6 for 95 Among which T1 and T2 represent temperature value for thermometer under test respectively Tref ...

Page 3: ...or the temperature measurement circuit or the ambient temperature exceed 10 40 50 104 There shall be ErC if the calibration process is not completed or EEPROM is abnormal 8 Sound volume 50 db the perpendicular distance from dB Volume sensor to thermometer is 10cm 9 Automatic shutdown function 10s 1s 10 Low voltage display function The product shall display low voltage signal if the voltage is belo...

Page 4: ...spital The cooperation with designated hospitals is subjected to precise clinical verification with the support of extensive clinical data and professional medical experts 2 Necessary safety instructions The device is not used for newborn baby 6 The LCD shall only display and M signal with M signal twinkling if there is no test data silence C F conversion LCD display How to change TempIR dual ther...

Page 5: ...instructions specified in cleaning and storage Please do not use the product if the temperature sensor or the Dual mode infrared thermometer shows any sign of damage Do not try to repair the product if it is damaged Please contact Customer Service Dual mode Infrared Thermometer consists of precision parts with high quality Please avaoid sharp shocks to or dropping the thermometer Do not twist the ...

Page 6: ...r it is suggested to wait for more than 30 minutes and please follow the rule 2 7 If the person having temperature takenis moved to another room or area it is suggested to wait more than 10 minutes and please follow the rule 2 8 Do not hold Dual mode Infrared Thermometer for long time as it is highly sensitive to heat Dual mode Infrared Thermometer has undergone clinical test it is safe and accura...

Reviews: