background image

TM

TM

Page <1>

V1.0

28/12/21

Newark.com/exclusive-brands
Farnell.com/exclusive-brands
Element14.com/exclusive-brands

Part Number: 72-10495, 72-10500 and 72-10505

Digital-Control and Programmable  

Twin DC Power Supply

User Manual

Summary of Contents for TENMA 72-10495

Page 1: ...1 V1 0 28 12 21 Newark com exclusive brands Farnell com exclusive brands Element14 com exclusive brands Part Number 72 10495 72 10500 and 72 10505 Digital Control and Programmable Twin DC Power Supply User Manual ...

Page 2: ...personnel AC Input AC input voltage 110V 120V 220V 230V 50 60Hz Connect the protective grounding conductor of the AC power cord to an earth ground in order to avoid electrical shock Operation Environment Location Indoor no direct sunlight dust free almost non conductive pollution Relative Humidity 80 Altitude 2000m Temperature 0 C to 40 C Storage Environment Location Indoor Relative Humidity 70 Te...

Page 3: ...o 10mV 1mA 72 10505 4 digit 4 digit No 10mV 1mA Performance Low noise cooling fans controlled by heatsink temperature Operation Constant voltage constant current operation Output on off control Digital panel control Twin 5 sets of panel setup save recall Coarse and fine voltage current control Software calibration Beep output Key lock function Protection Overload protection Reverse polarity protec...

Page 4: ...TM TM Page 4 V1 0 28 12 21 Newark com exclusive brands Farnell com exclusive brands Element14 com exclusive brands Front Panel Overview Storage Indication Brief Introduction of Panel Operation ...

Page 5: ...er switch again to turn the power off Output ON OFF Panel Operation The key LED will turn on once you have pressed the output key to turn output on The key LED will then turn off once you have pressed the output key again to turn off output Note If there are any of the following conditions the output will automatically turn off OVP means there is abnormal high voltage output or input on the output...

Page 6: ...y for two seconds again Front Panel Lock Press the LOCK key to lock the front panel key operation The key LED will tum on To unlock press and hold the LOCK key for two seconds Output Setup Panel Operation Connect the load to the front port CH1 Press the Voltage Current key to switch between the voltage adjustment and current adjustment Adjust the voltage and current with the Voltage Current adjust...

Page 7: ...mperatures ranging from 25 C down to 5 C and after being warmed up for 20 minutes Part Number 72 10495 72 10500 72 10505 Voltage Range 0 30V 0 30V 0 30V Current Range 0 5A 0 3A 0 3A Load Regulation Voltage Current 0 1 5mV 0 1 10mA 0 01 3mV 0 1 5mA 0 01 3mV 0 1 5mA Line Regulation Voltage Current 0 01 3mV 0 1 3mA 0 01 3mV 0 1 3mA 0 01 3mV 0 1 3mA Setup Resolution Voltage Current 10mV 1mA 10mV 1mA 1...

Page 8: ...liance on the Information or use of it including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to limit or restrict the Group s liability for death or personal injury resulting from its negligence TENMA is the registered trademark of Premier Farnell Limited 2019 Part Number 72 10495 72 10500 72 1...

Reviews: